Spectral Absorption Properties of Ultrananocrystalline Diamond/Amorphous Carbon Composite Thin Films Prepared by Pulsed Laser Deposition
スポンサーリンク
概要
- 論文の詳細を見る
The spectral absorption properties of ultrananocrystalline diamond (UNCD)/amorphous carbon composite films grown by pulsed laser deposition with graphite were experimentally investigated. The indirect optical band gaps estimated from the absorption spectrum were 1.0 eV and approximately 5.65 eV, which correspond to those for the amorphous carbon surrounding the UNCDs and for UNCDs themselves, respectively. In addition, the spectrum revealed a direct gap having a value of approximately 2.2 eV. One probable origin can be the presence of grain boundaries between UNCDs and amorphous carbon since they are specific to UNCD/amorphous carbon; further, its appearance is consistent with the theoretical predictions.
- Japan Society of Applied Physicsの論文
- 2007-10-25
著者
-
Itakura Masaru
Department Of Applied Science For Electronics And Materials Kyushu University
-
Kuwano Noriyuki
Department Of Applied Science For Electronics And Materials Interdisciplinary Graduate School Of Eng
-
Hara Takeshi
Department Of Animal Resource Sciences Graduate School Of Agricultural And Life Sciences The Univers
-
Nagayama Kunihito
Department Of Aeronautics And Astronautics
-
Yoshitake Tsuyoshi
Department of Applied Physics, Faculty of Engineering, Kyushu University
-
Nagano Akira
Department of Applied Science for Electronics and Materials, Kyushu University, Kasuga, Fukuoka 816-8580, Japan
-
Kuwano Noriyuki
Department of Applied Science for Electronics and Materials, Kyushu University, Kasuga, Fukuoka 816-8580, Japan
-
Itakura Masaru
Department of Applied Science for Electronics and Materials, Kyushu University, Kasuga, Fukuoka 816-8580, Japan
関連論文
- Microstructure Analysis of High Coercivity PLD-Made Nd-Fe-B Thick-Film Improved by Tb-Coating-Diffusion Treatment
- Synchronous and metachronous multicentric squamous cell carcinomas in the upper aerodigestive tract
- Performance Evaluation of a CAD System for Detecting Masses on Mammograms by Using the MIAS Database
- Brain CT Scoring Method Using Normal CT Scans to Detect Bain Damage for Emergency Medical Care(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Development of whole breast ultrasound system with CAD function(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Properties of Monolithic Silica Columns for HPLC
- An improved powell method for registration of MRI and MRA (医用画像)
- A Case of Porphyria Cutanea Tarda with Hemangioma of the Liver
- Microstructure Analysis of Sintered Nd-Fe-B Magnets Improved by Tb-Vapor Sorption
- Evaluation of Blood Cultures Following Laparoscopy