To enhance field emission properties, magnesium oxide (MgO) thin films were coated on the top of aluminum-doped zinc oxide (ZnO:Al) whiskers. The crystalline form of MgO was used as a representative material showing a high secondary-electron-emission An electron emission experiment was performed for 1000 h using an emitter consisting of the aggregated MgO/ZnO:Al whiskers. Scanning electron microscopy was conducted to compare the emission site images obtained before and after 1000 h operation. Furthermore, in this paper, Fowler–Nordheim plots are presented to explain the changing phenomenon of the field enhancement factor and the effective work function of the emission site before and after operation. Finally, a model of the electron emission of a MgO/ZnO:Al whisker-type field emitter is proposed.
- 2008-06-25
著者
-
西野 純一
Nagaoka University Of Technology
-
西野 純一
長岡技科大
-
Saitoh Hidetoshi
Department Of Bioresource Science Obihiro University Of Agriculture And Veterinary Medicine
-
Ito Haruhiko
Department Of Chemistry Faculty Of Science The University Of Tokyo
-
NISHINO Junichi
Department of Chemistry, Nagaoka University of Technology
-
Ohshio Shigeo
Department Of Chemistry Nagaoka University Of Technology
-
Nishino J
Department Of Chemistry Nagaoka University Of Technology
-
Ohkawara Yoshiaki
Department Of Chemistry Nagaoka University Of Technology
-
Ito Haruhiko
Department of Materials Science, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka, Niigata 940-2188, Japan
-
Ooki Satoshi
Department of Materials Science, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka, Niigata 940-2188, Japan
-
Nishino Junichi
Fukui National College of Technology, Geshi, Sabae, Fukui 916-8507, Japan
-
Saitoh Hidetoshi
Department of Materials Science, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka, Niigata 940-2188, Japan
関連論文
- HIPを利用した高密度ペロブスカイトLaNiO_3の作製
- Interface software for DOSXYZnrc Monte Carlo dose evaluation on a commercial radiation treatment planning system
- Production design and evaluation of a novel breast phantom with various breast glandular fractions
- Effects of Density Changes in the Chest on Lung Stereotactic Radiotherapy
- 262 Develompent of an accurate dose calculation system for remotely supporting radiotherapy(Bases of radiotherapy, Abstracts of the 46th Annual Meeting of the Japan Radiation Research Society)
- Heavy ion CT system based on measurement of residual range distribution
- Nonlinear Effect on Noise Power Spectrum for Quantum Mottle in Radiographs
- A Study of the Bone Scintigraphy of the Bata ray Nuclide for the Treatment
- Measurements of energy dependence in image detectors using monochromatized X-ray
- A Study of Scatter-Primary Dose Ratio in Stereotactic Irradiation