GSD-03 IMPROVEMENT IN FATIGUE STRENGTH OF STEEL GEAR BY NEXT-GENERATION CAVITATION PEENING(GEAR STRENGTH AND DURABILITY, INCLUDING GEAR MATERIALS AND HEAT TREATMENT TECHNIQUES)
スポンサーリンク
概要
- 論文の詳細を見る
A new cavitation peening processing unit was made to obtain greater peening effect. The purpose of this study is to investigate the improvement in fatigue strength of the steel gear cavitation-peened using this processing unit. The case-hardened steel rollers and gears were cavitation -peened under a processing time of 1 minute, and were fatigue-tested using a roller testing machine and a gear testing machine. The hardness and the compressive residual stress of the test specimens were increased by the cavitation peening. While, the surface roughness of the cavitation-peened test specimens was almost the same to that of the non-peened ones. In the fatigue tests, the fatigue life of the cavitation-peened test specimens was longer than that of the non-peened ones. Moreover, the fatigue strength of the test specimens was increased by the cavitation peening. This study revealed that the fatigue strength of steel gear was improved by the cavitation peening under a processing time of 1 minute.
- 一般社団法人日本機械学会の論文
- 2009-05-13
著者
-
YOSHIDA AKIRA
Department of Radiological Sciences, Hiroshima Prefectural College of Health Science
-
SOYAMA Hitoshi
Department of Nanomechanics Tohoku University
-
SEKI Masanori
Department of Mechanical Engineering, Okayama University
-
Seki Masanori
Department Of Mechanical Engineering Okayama University
-
Seki Masanori
Department Of Bacteriology Faculty Of Medical Sciences Kyushu University
-
Yoshida Akira
Department Of Mechanics And Robotics Hiroshima International University
-
Yoshida Akira
Department Of Agricultural Chemistry Nagoya University
-
SOYAMA Hitoshi
Department of Nanomechanics, Tohoku University
関連論文
- The Forefront for Novel Therapeutic Agents Based on the Pathophysiology of Lower Urinary Tract Dysfunction: Bladder Selectivity Based on In Vivo Drug–Receptor Binding Characteristics of Antimuscarinic Agents for Treatment of Overactive Bladder
- Physical Imaging Properties and Low-contrast Performance of a Newly Developed Flat-panel Digital Radiographic System
- PJ-464 Delayed Relaxation Detected by Regional Contraction Curve of Real-Time 3D Echocardiography Accurately Reflects Local Ischemia(Angina Pectoris, Clinical 2 (IHD) : PJ77)(Poster Session (Japanese))
- PE-462 Real-Time 3D Echocardiography Provides an Index of LV Diastolic Property : max dV/dt(Cardiac Function, Basic/Clinical 3 (M) : PE79)(Poster Session (English))
- PE-124 Real-Time 3D Echocardiography is a New Modality that Provides Accurate LV Volumetry : Comparisons with Conventional 2D-Echo Measurements(Echo/Doppler 5 (I) : PE21)(Poster Session (English))
- OJ-272 Quantitative Analysis of Regional Ventricular Motion by Real-Time 3D Echocardiography : Comparative Study to Semi-Quantifications by Conventional 2D-Echo Measurements and LVG(Echo/Doppler 10 (I) : OJ32)(Oral Presentation (Japanese))
- Surface Modification of Alloy Tool Steel for Forging Dies by Cavitation Peening
- Secondary Malignant Fibrous Histiocytoma Following Refractory Langerhans Cell Histiocytosis
- Fludarabine-Mediated Circumvention of Cytarabine Resistance Is Associated with Fludarabine Triphosphate Accumulation in Cytarabine-Resistant Leukemic Cells
- Cavitation Shotless Peening for Surface Modification of Alloy Tool Steel