Influence on retentive force of negative pressure generated between an electroformed telescope outer crown and improved zirconia inner crown
スポンサーリンク
概要
- 論文の詳細を見る
This study was performed to clarify the effect on retentive force of negative pressure generated between the improved inner zirconia crown and outer electroformed crown during vertical dislodgement. Inner crowns with 2° taper and a combination taper (0° taper for the cervical 1.5 mm and 2° taper above that) were made of zirconia, and five outer crowns were made by electroforming on the inner crowns. We measured the retentive force and the negative pressure generated between the inner and outer crowns with 20%, 40% and 60% glycerin solution substituted for saliva. There was no difference in peak retentive force between the 2° taper crowns and the combination taper crowns. The retentive force generating distance with the combination taper was significantly greater than with the 2° taper, and increased with the glycerin concentration of the solution in the combination taper type. The negative pressure generated between the double crowns using a zirconia inner crown with a combination taper increased with the glycerin concentration of the solution. The above findings suggest that the negative pressure generated between zirconia inner crowns and electroformed outer crowns increases the retentive force generating distance as the saliva viscosity increases.
- 大阪歯科学会の論文
著者
-
Okazaki Joji
Department Of Geriatric Dentistry Osaka Dental University
-
Nishizaki Hiroshi
Department Of Fermentation Technology Faculty Of Engineering Hiroshima University
-
Yamamoto Satsuki
Department Of Removable Prosthodontics And Occlusion Osaka Dental University
-
Tabata Katsuhiko
Department Of Removable Prosthodontics And Occlusion Osaka Dental University
-
Hara Yukari
Graduate School of Dentistry (Department of Removable Prosthodontics and Occlusion), Osaka Dental University
関連論文
- Inhibitory effects of four Chinese herbal medicines on oral squamous cancer cell lines
- Improved inner crown form in an electroformed telescope denture for the protection of abutment teeth
- Influence of Adipocytokines on Differentiation of Pro-osteoblastic Cells
- Statin Enhances Osteoblast Differentiation by Suppression of Runx2 Overexpression
- Measuring Sulfated Glycosaminoglycans in Gingival Crevicular Fluid Based on Dimethylmethylene Blue
- Statin Promotes Mineralization Potential in MC3T3-E1 Nonmineralizing Subclone
- Effect of an Inflammatory Mediator on the Syndecan Family Expression in Human Osteoblasts
- Alteration of Decorin Synthesis in Gingival Fibroblasts Induced by Interleukin-1β
- Matrix metalloproteinase-3 (MMP-3) in synovial fluid with temporomandibular joint disorders
- Expression of decorin mRNA and protein in human gingival fibroblasts induced by interleukin-1β
- Complete denture patients with ingestion and swallowing difficulties
- Gnathohexagraphic evaluation of ingestion and swallowing in elderly
- Expression of decorin in inflamed human gingival tissue
- Changes in Synovial Fluid N-Acetyl-β-Glucosaminidase Activity in the Human Temporomandibular Joint with Dysfunction
- High-Performance Liquid Chromatography Analysis of Chondroitin Sulfate Isomers in Human Periodontium
- Causes of cracks in laser welded cobalt-chromium alloys for dental use
- Bone Healing of Tooth Extraction Socket in Type 2 Diabetes
- Effect on mastication of experimental occlusal interferences in rats
- Activity changes in the open-field test related to loss of rat molar occlusal support
- Effect of Height of Occlusal Interference on Dopamine Release in the Prefrontal Cortex of Rats
- Bone Response after Tooth Extraction in Ovariectomized Rats
- Generation of retentive force by electroformed telescope crowns
- Changes in retention of electroformed telescope crowns over long-term use
- Retentive force characteristics of electroformed telescope crowns related to protection of abutment teeth
- Retentive force characteristics of electroformed telescope crowns
- Metallurgical Effects on Titanium by Laser Welding on Dental Stone
- Synthesis of Bitter Peptides Composed of Aspartic Acid and Glutamic Acid(Food & Nutrition)
- Retentive force characteristics of various partial denture retainers
- Thickness of oral mucosa under occlusal force
- How changes in localized pressure under an experimental acrylic plate covering the palatal mucosa affect salivary cortisol concentration and α-amylase activity
- Sjogren's Syndrome Complicated with Autoimmune Hepatitis and Antiphospholipid Antibody Syndrome
- Stability of beta tricalcium phosphate-coated mini-implants in rat tooth sockets
- Morphology of Lateral Pterygoid Muscle by Magnetic Resonance Imaging
- Influences of molar loss of rat on learning and memory
- Effect of application of calcium phosphate cement on titanium screw mini-implants in the cortical bone of dog femurs
- Generation of retentive force by an electroformed telescope crown on a zirconia inner crown
- Implants in mandibular incisor extraction sockets of diabetic aged rats
- Influence of decline of occlusal support on bilateral striatal dopamine release in rats
- Influence of different setting positions of maxillary major connectors on salivary stress markers
- Influence of different setting positions of maxillary major connectors on salivary stress markers
- Studies on N-glycopeptides. II. Separation of .ALPHA.- and .BETA.-amide of N-(L-aspartyl)-.BETA.-D-glucopyranosylamine obtained via N-(benzyloxycarbonyl)-L-aspartic anhydride.
- Adsorption of platelet-rich plasma on the surface of titanium and zirconia measured with QCM sensors
- Influence on retentive force of negative pressure generated between an electroformed telescope outer crown and improved zirconia inner crown
- In vivo behavior of surface-modified titanium implants after chemical processing at room temperature
- Influences of molar loss of rat on learning and memory