Dose Estimation of Human Fetus Exposed in Utero to Radiations from Atomic Bombs in Hiroshima and Nagasaki
スポンサーリンク
概要
- 論文の詳細を見る
The absorbed dose in the head of human fetus exposed in utero to gamma-rays and neutrons from the 1945 atomic bombs in Hiroshima and Nagasaki has been estimated as a function of distance from the hypocenter. The ratios of the absorbed dose in the fetal head to the inair tissue absorbed dose was determined using a depth-dose curve and a dose build-up factor experimentally determined with simulated radiation sources of the atomic bombs. The ratio was corrected for the angular distribution of the atomic bomb radiations. The results showed that the ratios varied depending on a distance from the hypocenter, a posture of mother and her stage of pregnancy at the time of exposure, and ranged from the minimum value of 0.56 to the maximum value of 0.70 for initial gamma-rays; 0.072 to 0.16 for recoil protons; 0.075 to 0.11 for gamma-rays from ^1H(n,γ)^2D reaction; 0.0030 to 0.0082 for protons from ^<14>N(n,p)^<14>C reaction. The absorbed dose in the fetal head at the end of first month of gestation and at 1,000 m from the Hiroshima hypocenter was 194 rads for initial gamma-rays; 22.2 rads for recoil protons; 15.8 rads for gamma-rays from the ^1H(n,γ)^2D reaction, and 1.22 rads for proton from the ^<14>N(n,p)^<14>C reaction.
- 日本放射線影響学会の論文
著者
-
丸山 隆司
放射線医学総合研究所
-
丸山 隆司
放射線医学総合研究所医学物理部
-
西澤 かな枝
放射線医学総合研究所重粒子医科学センター医学物理部
-
西澤 かな枝
日本大学 歯学部歯科放射線学教室
-
西沢 かな枝
放射線医学総合研究所
-
西村 明久
放射線医学総合研究所物理研究部
-
橋詰 雅
放射線医学総合研究所物理研究部
-
西沢 かな江
放医研
-
西澤 かな枝
独立行政法人 放射線医学総合研究所 医学物理部
-
橋詰 雅
放医研物理研究部
-
Maruyama T
Division Of Physics National Institute Of Radiological Sciences
-
橋詰 雅
放射線医学総合研究所
関連論文
- 歯科用コーンビームCTによる患者の臓器・組織線量と実効線量の推定
- 多機能歯科用CTによる患者の臓器・組織線量と実効線量の推定
- 乳房撮影時の平均乳腺線量; ガラス線量計による全国調査
- 肺がんCT検診の低線量化と画質のシミュレーションによる検討
- CT肺癌検診の被曝線量と画質 -シミュレーションによる検討
- Dose Estimation of Human Fetus Exposed in Utero to Radiations from Atomic Bombs in Hiroshima and Nagasaki
- 乳房X線撮影線量の全国調査 : 線量に影響を与える因子の解析
- 歯科X線撮影における実態調査, 集団実効線量の推定, 1999
- 各社CT装置のX線スペクトル測定と実効エネルギー評価
- 肺癌検診用MDCT(Multidetector-row CT)撮影マニュアル作成研究班報告(学術調査研究班報告)
- 肺がん検診用MDCT (Multidetector-row CT)撮影マニュアル作成研究班報告(学術調査研究班報告)
- 国内で起きた放射線治療装置設置中の作業従事者への放射線被ばく事故の特徴と線量評価
- X線診断による臓器・組織線量, 実効線量および集団実効線量
- X線診断における撮影および透視,1986年
- Estimations of Population Doses and Risk Estimates from Occupational Exposures in Japan, 1978 Part 2. Population Doses and Risk Estimates
- Estimations of Population Doses and Risk Estimates from Occupational Exposures in Japan, 1978 Part 1. Determinations of Organ or Tissue Doses and Effective Dose Equivalents
- 歯科X線撮影における集団実効線量の推定 : 1994年
- CT検査による被検者の被曝線量
- 小児CTガイドライン : 被ばく低減のために(ガイドライン)
- CT画像系において測定された line spread function (LSF) および point spread function (PSF) の精度評価法に関する研究
- 胸部CT検診撮影精度管理マニュアル作成班報告(学術調査研究班報告)
- 核医学における年間診療件数及び集団実効線量の推定
- UAEに対する被ばく及び被ばく軽減の検討(第59回総会学術大会放射線防護管理関連演題発表後抄録)
- マンモグラフィによる被曝線量評価のための平均乳房厚の検討
- Four Cases of Thorotrast Injury and Estimation of Absorbed Tissue Dose in Critical Organs
- Determinations of Organ or Tissue Doses to Survivors in Hiroshima and Nagasaki
- 広島・長崎の原爆γ線量の推定T65D、DS86そしてDS02
- 第22回放医研環境セミナー「生活と放射線」について
- Determination of Specific Activity of Cobalt (^Co/Co) in Steel Samples Exposed to the Atomic Bomb in Hiroshima
- 放射線障害防止関係法令の改正に伴う技術的対応--実効線量当量等の評価
- Effects of Ionizing Radiation on the Early Development of Oryzias Eggs
- Absorbed Dose Estimates in a Prolonged Caesium-137 Gamma Irradiation Facility for Mice
- IV.サイクロトロンによる速中性子線治療
- 胸部集団検診による国民線量の推定
- A Simulated Neutron Activation Experiment : Dose Estimation from Residual and Fallout Radioactivity
- Physical Dose Estimates for A-bomb Survivors-Studies at Chiba, Japan
- Effects of X-lrradiation of a Part of the Body on Mortality Rate and on Histological Changes in the Goldfish, Carassius auratus
- コーンビームCT装置による検査時の被曝線量
- 核医学診断・治療による国民線量およびリスクの評価(1) -件数, 年齢分布, および放射性医薬品に関する検討-
- Mammography装置の線量測定
- PET検査の時のトランスミッションスキャンによる被ばく線量の評価
- Evaluation of Radiation Risks from Medical Exposures in Japan
- Preliminary study on evaluation of medical exposures for atomic bomb survivors in Hiroshima and Nagasaki.
- わが国における職業被曝による集団実効線量当量,国民線量およびリスクの推定
- 小照射野コーンビームCT撮影における実効線量
- 歯科X線撮影に関する実態調査, 1994
- 歯軸方向撮影における被曝線量
- 歯科X線撮影に関する実態調査、1994
- 放射線治療における^Coガンマ線および高エネルギーX線の吸收線量の標準測定法
- Dose Estimation of Non-occupational Persons Accidentally Exposed to ^Ir Gamma-Rays
- 歯科領域におけるマルチスキャンCTによる被験者の実効線量の検討
- CT検査件数及びCT検査による集団実効線量の推定
- 核医学診断・治療による国民線量の評価(2) : 放射性医薬品別の年齢分布および集団実効線量
- 高感度X線像記録系と解像力
- 2MeVおよび30MeV速中性子線照射をうけたアルテミア卵のRBE
- 獣医学領域における放射画像診断に関する基礎的研究-1-馬胸部ファントムに対するCTおよびスキャノグラフィ-の解像力〔英文〕
- Reassessment of Gamma-ray Doses in Hiroshima and Nagasaki : I. DOSIMETRY
- 医療用密封小線源の管理-3-密封小線源治療における安全管理-2-医療担当者の安全管理
- 医療用密封小線源の管理-3-密封小線源治療における安全管理-1-臨床における安全管理
- 可搬式工業X線装置における放射線防護について
- 診断用X線による国民線量の推定(1974)第四報 胎児の被爆線量
- 診断用X線による国民線量の推定(1974) 第一報 撮影照射回数,透視件数および診断件数について
- (3)生殖腺防護を考慮して乳幼児の股関節撮影について(関東部会)
- X線透視診断による骨髄線量の推定
- (2)受検者の被ばくの観点から(ワークショップ-より良い撮影技術を求めて(その89)-健康診断画像をデジタル化した際の問題点と解決策,テーマA:一般「がん検診画像のデジタル化について」)
- 被ばく管理(よりよい撮影技術を求めて(その65))
- 医療被ばくに関する特集に当たって
- 医療被曝のリスクと低減
- 遠隔放射線治療による国民線量の推定 第3報 がんの有意線量とリスク
- 診断用X線によるリスクの推定 第3報 X線診断による国民線量と集団のリスク
- 診断用X線によるリスクの推定 第2報 X線診断による個人のリスク
- 医療被曝のリスク推定方法について
- 診断用X線によるリスクの推定 第1報 撮影回数,診断件数および透視件数について
- 密封小線源治療による国民線量の推定
- がん有意因子について
- 診断用放射線被曝における個人のリスクの定量的評価
- X線診断によるリスクの推定
- 胸部集団検診による国民線量の推定
- 4.CT受診者の実効線量評価
- CT検査によるリスクの推定(1979)-3-国民線量,個人のリスクおよび集団のリスク
- CT検査によるリスクの推定(1979)-2-CT検査による臓器・組織の線量
- CT検査によるリスクの推定(1979)-1-スキャン回数及び検査件数
- 速中性子線治療用コリメ-タの設計およびその特性
- サイクロトロン中性子線照射によるマウスの白内障誘発
- ヒトのリンパ球における染色体異常誘発に関するサイクロトロン速中性子線の効果
- マウスの骨髄障害死ならびに精巣重量減少にたいするサイクロトロン中性子線の生物効果
- 放医研サイクロトロン速中性子線の深部照射に関する細胞致死効果
- 事故時における被曝線量の推定 1. ヒューマンカウンタによる全身 24Na 量の測定
- EMI5005による生殖線,甲状腺,水晶体及び骨髄線量の測定
- 放射線高感受性群に対するスクリーニングMMGのリスク
- マンモグラフィの診断精度の相違が乳癌検診のリスク/ベネフィット関係に及ぼす影響
- コーンビームCT用ヒール効果補償フィルタの開発 : 被ばく線量低減に威力
- 国際会議・学会レポート 国際標準化機構/原子力領域/放射線防護(ISO/TC85/SC2)の国際会議に出席して
- 密封小線源治療による国民線量の推定
- 骨密度測定における被検者の被曝線量
- 日本人のMIRD表の作表プログラム
- 高感度X線像記録系と解像力
- メバトロンX線治療室における中性子線量当量の測定
- 吸収線量計算のための人体ファントムの画像化
- 顎顔面CT撮影時の被曝線量