Characterization and Improvement of a Laser-Assisted Pulsed Plasma Thruster
スポンサーリンク
概要
- 論文の詳細を見る
To investigate mechanisms of high-specific impulse characteristics, or high speed plasma generation, of a laser-assisted pulsed plasma thruster, speeds of ions of plasma plumes exhausted from the thruster were measured with the time-of-flight (TOF) measurement. In the measurement, temporal variations of ion currents exhausted from the thruster were measured with a Faraday cup. From the results of single Faraday cup measurement, placed at 400 mm away from the thruster, the maximum speed of ions of 169 km/sec at charge voltage of 2000 V (or charge energy of 14 J) was obtained. On the other hand, with double Faraday cup measurement, installed at 400 mm and 600 mm, the maximum ion speed was 220 km/sec at charge voltage of 2000 V.
- THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCESの論文
著者
-
Yamada Osamu
Department Of Cardiovascular Dynamics National Cardiovascular Center Research Institute
-
Kobayashi Haruki
Department Of Mechanical Engineering Tokyo Instit
-
Horisawa Hideyuki
Department Of Aeronautics And Astronautics
-
Hosokawa Hiroshi
Department Of Dermatology Kansai Medical University
-
HORISAWA Hideyuki
Department of Aeronautics and Astronautics, Tokai University
関連論文
- Primary adrenal lymphoma discovered as an incidentaloma: case report and review of the literature
- Severity Indices of Right Coronary Cusp Prolapse and Aortic Regurgitation Complicating Ventricular Septal Defect in the Outlet Septum : Which Defect Should Be Closed?
- Intravenous Indomethacin Therapy in Infants With a Patent Ductus Arteriosus Complicating Other Congenital Heart Defects
- Eccentric Aortic Regurgitation in Patients With Right Coronary Cusp Prolapse Complicating a Ventricular Septal Defect
- Great artery dimensions late after the Fontan operation : The optimal stent size for dilating stenotic lesions after the Fontan
- Life-Threatening Pulmonary Edema Following Unilateral Stent Implantation for Bilateral Branch Pulmonary Stenosis : Recovery After Contralateral Stent Implantation
- Long-Term Results of Saphenous Vein Graft for Coronary Stenosis Caused by Kawasaki Disease(Cardiovascular Surgery)
- -115- CHANGES OF CARDIAC PERFORMANCE BEFORE AND AFTER BLALOCK-TAUSSIG SHUNT IN TETRALOGY OF FALLOT : Congenital Heart Disease, Kawasaki Disease : FREE COMMUNICATIONS(I) : PROCEEDINGS OF THE 51th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIET
- Pulmonary Valve Replacement in Adult Patients With a Severely Dilated Right Ventricle and Refractory Arrhythmias After Repair of Tetralogy of Fallot
- Efficacy and Safety of Sotalol for Refractory Tachyarrhythmias in Congenital Heart Disease