Electric Measurement of Melting Phenomena for Breaking Relay Contacts
スポンサーリンク
概要
- 論文の詳細を見る
Using the transient current switch circuit in parallel with the energizing switching contacts for timely control of breaking operation, the increase of contact voltage is suppressed at the last stage of the breaking of electric contacts. Breaking contact voltage Vc and current Ic of electromagnetic relays with Ag contacting electrodes were measured with 12.5-50V and 0.1-20A for two hinge springs (Spring constants; 2N/mm and 0.2N/mm). The current-decreasing process was clearly measured at the melting voltage Um. After Vc = Um, the breaking time of contact current did not depend on mechanical motion controlled by the two hinge springs and energizing power-supply voltage, but depended on the contact current. The residue of melt electrode was observed optically as a white fusion spot, with radius depending on the energizing current.
- (社)電子情報通信学会の論文
- 2009-08-01
著者
-
Oikawa Masahiro
Ishinomaki Senshu University Faculty Of Science And Engineering
-
Takatsu Nobuo
Ishinomaki Senshu University Faculty Of Science And Engineering
-
Takatsu Nobuo
Faculty Of Engineering Tohoku University
-
Wakatsuki Noboru
Ishinomaki Senshu University Faculty Of Science And Engineering
-
Wakatsuki Noboru
Faculty Of Science And Engineering At Ishinomaki Senshu University
-
OIKAWA Masahiro
Faculty of Science and Engineering, Ishinomaki Senshu University
-
Oikawa Masahiro
Faculty Of Science And Engineering Ishinomaki Senshu University
関連論文
- The Bending Strength of Carburized Fine Module Gear Teeth : Carburizing Conditions and Their Effects on the Fatigue Strength
- Bending Strength of Carburized SCM420H Spur Gear Teeth
- Development of DC Current Switching Hub using a Transient Current Switch Circuit for Arc Suppression
- Fabrication Process of Nonarcing Power MEMS Switch(Relays and Switches, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Fabrication process of non arcing power MEMS relay(Session 3 : Relays)
- High-Speed Forming of Metal Sheets by Electromagnetic Force
- Basic Research on the Vibratory Travelling Element : Travelling mode and Velocity
- Measurement of Bouncing of Reed Switch Due to Coulomb's Electrostatic Force(Relays & Switches,Recent Development of Electromechanical Devices (Selected Papers from ICEC2006))
- Contacting force of a reed switch at breaking operation (国際セッションIS-EMD2005) -- (Relays and Switches)
- Influence of shear vibration over Au-Au electric contact phenomenon (国際セッションIS-EMD2002〔英文〕)
- Time-Coordinated Switching Relay for Arc Discharge Suppression(Relays and Switches, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Influence of Shear Vibration over Au-Au Electric Contact Phenomenon(Recent Development of Electro-Mechanical Devices (IS-EMD 2002))
- Influence of Shear Vibration over Au-Au Electric Contact Phenomenon
- Equivalent Circuit Analysis for Time-Coordinated Non-arcing Operation of Reed Switches(Relays & Switches,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Examination of cluster model of arc ignition at electric contacts
- Analysis of electric contacts using an electric conductive cluster and an electric field effect cluster
- Examination of a Langevin-Type Transducer Using a LiNbO_3 Single Crystal
- Measurement of Breaking Phenomena of Ag and Au Crossbar Electric Contacts Depending on Contacting Spots
- Examination of Cluster Model for Metal Melting of Electric Contacts
- Analytical Model of Melting Phenomena for Breaking Relay Contacts
- Analytical Model of Melting Phenomena with Breaking Relay Contacts
- Statistical Analysis of Dynamic Loads on Spur Gear Teeth : Experimental Study
- Statistical Analysis of Dynamic Loads on Spur Gear Teeth : Effect of Shaft Stiffness
- Dynamic Loads on Spur Gear Teeth Caused by Teeth Impact
- Approximate Solution of a Gear System Subjected to Random Excitation
- Jump Phenomena in Gear System to Random Excitation
- Dynamical Distinctive Phenomena in Gear System
- Mechanical Fracture of Piezoelectric Single Crystal Chip Resonator due to High Input Power(Special Issue on Current Electromechanical Devices and Their Materials with Recent Innovations)
- Breaking Contact Phenomena of Time-coordinated Non-arcing Relay(Session 3 -Arc Interruption-)
- Electric Measurement of Melting Phenomena for Breaking Relay Contacts
- Electric Measurement of Melting Phenomena for Breaking Relay Contacts
- Breaking Contact Phenomena of a Time-coordinated Non-arcing Relay
- FOREWORD
- Development of DC Current Switching Hub using a Transient Current Switch Circuit for Arc Suppression
- Improving the Sensitivity of H-Type LiTaO_3 Piezoelectric Crystal Gyroscopes (Special Issue on Electromechanical Devices and Their Materials)
- LiTaO3 Shear Wave Resonator for Viscosity Measurement of Polymer Liquid in MHz Range
- Experimental Analysis of Transient Phenomena from Metal Melting to Electric Discharge during Breaking Operations of Electric Contacts
- A Study on Shear Wave LiTaO3 Resonators for Viscosity Sensor
- Equivalent Circuit Analysis for the Transient Phenomena from Elastic Contact to Breaking Contact through Metal Melting