Time-Coordinated Switching Relay for Arc Discharge Suppression(Relays and Switches, <Special Section>IS-EMD2004-Recent Development of Electro-Mechanical Devices)
スポンサーリンク
概要
- 論文の詳細を見る
We propose a new electric contact device for arc discharge suppression. The functions of conventional electric contacts are categorized into energizing switch contacts and transient current switch contacts. A capacitor is connected in series to a transient current switch. Suppression of power consumption and arc discharge at breaking contacts are proposed, experimentally measured, and theoretically analyzed. The transient V-I characteristics at breaking contacts are controlled by the transient current switch and the capacitor. The transient responses at contacts were numerically derived by SPICE, and the energizing switch contacts voltage could be controlled to less than the minimum arc voltage. Using 2 conventional relays, no arc ignition at breaking contacts was confirmed for 50 V/25 A.
- 社団法人電子情報通信学会の論文
- 2005-08-01
著者
-
YONEZAWA Yu
Ishinomaki Senshu University
-
WAKATSUKI Noboru
Ishinomaki Senshu University
-
Yonezawa Yu
Fujitsu Media Device Ltd. Akashi‐shi Jpn
-
AKIBA Yuuich
Ishinomaki Senshu University
-
Wakatsuki Noboru
Ishinomaki Senshu University Faculty Of Science And Engineering
-
Wakatsuki Noboru
Ishinomaki Senshu Univ. Miyagi Jpn
関連論文
- Development of DC Current Switching Hub using a Transient Current Switch Circuit for Arc Suppression
- Fabrication Process of Nonarcing Power MEMS Switch(Relays and Switches, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Fabrication process of non arcing power MEMS relay(Session 3 : Relays)
- Contacting force of a reed switch at breaking operation (国際セッションIS-EMD2005) -- (Relays and Switches)
- Time-Coordinated Switching Relay for Arc Discharge Suppression(Relays and Switches, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Equivalent Circuit Analysis for Time-Coordinated Non-arcing Operation of Reed Switches(Relays & Switches,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Examination of cluster model of arc ignition at electric contacts
- Analysis of electric contacts using an electric conductive cluster and an electric field effect cluster
- Measurement of Breaking Phenomena of Ag and Au Crossbar Electric Contacts Depending on Contacting Spots
- Examination of Cluster Model for Metal Melting of Electric Contacts
- Analytical Model of Melting Phenomena for Breaking Relay Contacts
- Analytical Model of Melting Phenomena with Breaking Relay Contacts
- Electric Measurement of Melting Phenomena for Breaking Relay Contacts
- Electric Measurement of Melting Phenomena for Breaking Relay Contacts
- Development of DC Current Switching Hub using a Transient Current Switch Circuit for Arc Suppression
- Melting and Discharge Phenomena of Breaking Ag Contacts Using a Precisely Controlled Piezoelectric Actuator