Density Effect of X-Ray Emission from Porous Specimens in Quantitative Electron Probe Microanalysis
スポンサーリンク
概要
- 論文の詳細を見る
Density effect of X-ray emission was found for tablet specimens of various densities. Graphite, Cr_2O_3, CuO and ZnS, which were less than 1 μm in particle size were used as specimens. The specimen density was changed from about 1 to 4 g/cm^3. Electron probe was made into a circle with a diameter of about 10 μm by defocusing on the specimen surface. The results show that the specimen with lower density always gives lower X-ray emission than that with higher density and X-ray intensity from the specimen with the lowest density becomes 70% to 80$ of that from a single crystal. To examine the origin of this density effect, experimental F(χ) curves and a back scattering factor R were measured as functions of the specimen density. The results show that f(χ) curves and R-factors scarcely depend on the specimen density, but F(0) factors greatly depend on it. Thus it is concluded that the stopping power of electrons in porous specimens plays an important role to the density effect. Lastly, a procedure of correcting for this effect has been suggested.
- 社団法人応用物理学会の論文
- 1969-12-05
著者
-
Nakajima Masato
Department Of Cardiovascular Surgery Yamanashi Central Hospital
-
Ichinokawa Takeo
Department Of Applied Physics School Of Science And Engineering Waseda University
-
Kobayashi Hideo
Department Of Bacteriology Ii National Institute Of Infectious Diseases
-
Nakajima Masato
Department Of Applied Physics Waseda University
-
Kobayashi Hideo
Department Of Applied Physics Waseda University
関連論文
- Influence of Interlayer Thickness on the Intensity of Singular Stress Field in 3D Three-Layered Joints under an External Load
- Clinical significance of histological grading and staging for predicting the effectiveness of steroid therapy in IgA nephropathy
- Clinical assessment of serum cystatin C as a marker of glomerular filtration rate in patients with various renal diseases
- Acute renal failure in a patient with hemophagocytic syndrome
- Decreased expression of vascular endothelial growth factor in glomeruli of puromycin aminonucleoside nephrosis
- Clinicopathological study of lgA nephropathy in adults: The influence of onset age on clinical and renal histological findings and on the effect of steroid therapy
- B-20-40 Energy Consumption Evaluation for Traffic Adaptive MAC Control in IEEE 802.15.4 cluster-based WSNs
- Aortic Operation after Previous Coronary Artery Bypass Grafting : Management of Patent Grafts for Myocardial Protection
- Leaflet Folding Plasty for Mitral Valve Repair : Technical Application and Early Outcome
- Idiopathic Hypertrophic Cranial Pachymeningitis with Perifocal Brain Edema : Case Report
- Trigeminal Neuralgia Associated with Tentorial Agenesis and Temporal Lobe Herniation : Case Report
- Pineal Germinoma With a Prominent Epithelioid Cell Granuloma Component
- Electro- and Thermomigration of Metallic Islands on Si(100) Surface
- Unsupervised Structural Damage Diagnosis Based on Change of Response Surface Using Statistical Tool : Application to Damage Detection of Composite Structure
- 114 Bearing Failure Detection of Bolted Composite Joints Using Electric Resistance Change Method
- Midterm outcome of leaflet folding plasty for mitral regurgitation due to posterior leaflet prolapse
- Acute pulmonary embolism after cerebral infarction associated with a mobile thrombus in the ascending aorta
- Evaluation of Reliable Multicast Delivery in Base Station Diversity Systems
- Complexity Reduced Maximum Likelihood Detection for SDM-OFDM System(Wireless Communication Technologies)
- Primary Lung Cancer with Growth into the Lumen of the Pulmonary Artery
- Coronary-Coronary Artery Bypass for Right Coronary Revascularization in Patients Undergoing Graft Replacement of the Ascending Aorta
- Measurement of Finite Amplitude Ultrasound Wave Fields by Light Beam CT : Acoustical Measurements and Instrumentation
- Optical Observation of Finite Amplitude Ultrasonic Waveform : Acoustical Measurements and Instrumentation
- Effects of Superoxide Dismutase on the Acetylcholine-induced Relaxation Response in Cholesterol-fed and Streptozotocin-induced Diabetic Mice
- A New Normalization Method for the Electron Energy-Loss Spectrum
- Experimental Study of Inelastic Process at the Crystal Surface in Angle Resolved Low-Energy Electron Energy Loss Spectroscopy
- On Anomalous Phase Change of Ammonium Nitrate NH_4NO_3.
- Effect of Stress on Domain Structure of Tungsten Trioxide WO_3.
- Performance Evaluations of DCT Interpolation-Based Channel Estimation Method for MIMO-OFDM System(Wireless Communication Technologies)
- B-5-269 Adaptive Resource Allocation Method for OFDMA System
- Proposal of Grouping Adaptive Modulation Method for Burst Mode OFDM Transmission System(Special Issue on Multiple Access and Signal Transmission Techniques for Future Mobile Communications)
- Abdominal Aortic Grafting for Renal and Lower Extremity Hypoperfusion Due to Aortic Dissection with Progressive Thrombosis of a False Channel
- Application of Electric Potential Method to Smart Composite Structures for Detecting Delamination
- CROSS-SECTIONAL AND M-MODE ECHOCARDIOGRAPHIC EVALUATION IN THE NORMAL HUMAN FETUS AND NEW BORN : Echocardiography : FREE COMMUNICATIONS (Abstract) : 45 Annual Scientific Meeting, Japanese Circulation Society
- Holocord Astrocytoma : Case Report
- A Comparison of Biopsy Through a Parasternal Anterior Mediastinotomy Under Local Anesthesia and Percutaneous Needle Biopsy for Malignant Anterior Mediastinal Tumors
- Contralateral Neuropathic Pain and Neuropathology in Dorsal Root Ganglion and Spinal Cord Following Hemilateral Nerve Injury in Rats
- Sympathectomy Reduces Mechanical Allodynia, Tumor Necrosis Factor-Alpha Expression, and Dorsal Root Ganglion Apoptosis Following Nerve Root Crush Injury
- CROSS-SECTIONAL AND M-MODE ECHOCARDIOGRAPHIC EVALUATION IN THE NORMAL HUMAN FETUS AND NEW BORN : Electrophysiology : 46th Annual Scientific Meeting, Japanese Circulation Society
- Proposal of Clipping and Inter-Modulation Noise Mitigation Method for OFDM Signal in Non-linear Channel(Multi-carrier Signal Processing Techniques for Next Generation Mobile Communications-Part 2)
- Decision-tree sensitivity analysis for cost-effectiveness of whole-body FDG PET in the management of patients with non-small-cell lung carcinoma in Japan
- Proposal of Improved PTS Method for STBC MIMO-OFDM Systems
- Slot Assignment Method for CDMA/NC-PRMA Systems in Multi-Cell Environments(Special Section on Multi-dimensional Mobile Information Networks)
- Proposal of Symbol Timing and Carrier Frequency Synchronization Methods for Burst Mode OFDM Signal(Special Issue on Multiple Access and Signal Transmission Techniques for Future Mobile Communications)
- BS-9-6 Time Domain Maximum Likelihood Channel Estimation and Equalization Method for OFDM System Without Guard Interval(BS-9. Broadband wireless communications techniques)
- Kikuchi Patterns and Inelastic Scattering
- Reoperation in Mitral Valve Repair for Regurgitant Mitral Valve Disease
- Energy Analysis of Kikuchi Patterns
- Relationship between Regularity of Scatterers' Distribution and Speckle Appearing on Ultrasonic Echograms : Ultrasonic Imaging and Microscopy
- Charging Effect of Specimen in Scanning Electron Microscopy
- Electron Energy Analysis by a Cylindrical Magnetic Lens
- Absorbed Specimen Current Anomaly of Cu-Zn Diffusion Couple in Electron Scanning Microscope
- Observation of Crystal Defects by Pseudo-Kissed Lines on X-Ray Projection Micrograph
- Pseudo-Kikuchi Patterns in Reduced Scanning Region for Monocrystals of Silicon
- Effect of Electron Source to Energy Resolution in Electron Velocity Analysis : Interpretation of Boersch Effect
- Density Effect of X-Ray Emission from Porous Specimens in Quantitative Electron Probe Microanalysis
- Valiation of X-Ray Emission from GaAs Single Crystal with Incident Electron Beam Direction
- Contrast Reversals of Pseudo-Kikuchi Band and Lines Due to Detector Position in Scanning Electron Microscopy
- X-Ray Microdiffraction with a Scanning X-Ray Microanalyzer
- Measurements of Ratio of Abnomal to Normal Absorption Coefficients for Electrons in Crystal from Pseudo-Kikuchi Patterns
- Contrast Reversal of Kikuchi Bands in Transmission Electron Diffraction
- A Rb-Sr geochronological study on Tatehira granodiorite,Oshima Peninsula,southwest Hokkaido,Japan(短報)
- Measurements of Evaporated Film Thickness and Concentration by Electron Probe X-Ray Microanalyzer
- Asymmetric Radio Resource Assignment Scheme for Connection-less Services in CDMA/Shared-TDD Cellular Packet Communications(Wireless Communication Technology, Multi-dimensional Mobile Information Networks)
- Application of Genetic Algorithms to Stiffness Optimization of Laminated Composite Plates with Stress-Concentrated Open Holes
- Resource Allocation Based on TCP Performance in Base Station Diversity Systems
- Forty-year durability of a Smeloff-Cutter ball valve prosthesis in the mitral position
- Simple Electron Monochromator of Three-Diaphragm Einzel Lens