Observation of Crystal Defects by Pseudo-Kissed Lines on X-Ray Projection Micrograph
スポンサーリンク
概要
- 論文の詳細を見る
When divergent X-rays from the source of size below 1 μ are diffracted from Fe-Si (Si 3%) single crystals of about 0.05 mm thickness, a pseudo-Kossel pattern superimposed with the X-ray projection micrograph is obtained. Distortion of absorption lines in the pseudo-Kossel pattern shows the change in orientation or spacing of the crystal planes at their locations on the X-ray projection micrograph. By traversing the X-ray source on a target film, pseudo-Kossel lines change their locations on the X-ray projection micrograph. Thus, two-dimensional stress distribution in the neighborhood of the crystal defect can be revealed. The detectable limit of distortion is about 10^<-4> in order and the resolution of the X-ray projection micrograph is about 1 μ.
- 社団法人応用物理学会の論文
- 1966-01-15
著者
-
ICHINOKAWA Takeo
Department of Applied Physics, Waseda University
-
Ichinokawa Takeo
Department Of Applied Physics School Of Science And Engineering Waseda University
関連論文
- Electro- and Thermomigration of Metallic Islands on Si(100) Surface
- A New Normalization Method for the Electron Energy-Loss Spectrum
- Experimental Study of Inelastic Process at the Crystal Surface in Angle Resolved Low-Energy Electron Energy Loss Spectroscopy
- On Anomalous Phase Change of Ammonium Nitrate NH_4NO_3.
- Effect of Stress on Domain Structure of Tungsten Trioxide WO_3.
- Kikuchi Patterns and Inelastic Scattering
- Energy Analysis of Kikuchi Patterns
- Charging Effect of Specimen in Scanning Electron Microscopy
- Electron Energy Analysis by a Cylindrical Magnetic Lens
- Absorbed Specimen Current Anomaly of Cu-Zn Diffusion Couple in Electron Scanning Microscope
- Observation of Crystal Defects by Pseudo-Kissed Lines on X-Ray Projection Micrograph
- Pseudo-Kikuchi Patterns in Reduced Scanning Region for Monocrystals of Silicon
- Effect of Electron Source to Energy Resolution in Electron Velocity Analysis : Interpretation of Boersch Effect
- Density Effect of X-Ray Emission from Porous Specimens in Quantitative Electron Probe Microanalysis
- Valiation of X-Ray Emission from GaAs Single Crystal with Incident Electron Beam Direction
- Contrast Reversals of Pseudo-Kikuchi Band and Lines Due to Detector Position in Scanning Electron Microscopy
- X-Ray Microdiffraction with a Scanning X-Ray Microanalyzer
- Measurements of Ratio of Abnomal to Normal Absorption Coefficients for Electrons in Crystal from Pseudo-Kikuchi Patterns
- Contrast Reversal of Kikuchi Bands in Transmission Electron Diffraction
- Measurements of Evaporated Film Thickness and Concentration by Electron Probe X-Ray Microanalyzer
- Simple Electron Monochromator of Three-Diaphragm Einzel Lens