The purpose of this study was to evaluate the influence of air-abrasion and subsequent heat treatment on the shear bond strength of the bond between indirect composites and a zirconia material. Four surface preparations were employed; ground flat, then heated to regenerate the crystal phase (C); air-abraded with alumina for 10 s (S10), for 20 s (S20), and air-abraded for 10 s and heated (H). Disks were primed with Alloy Primer and bonded either with Estenia or with Gradia composite. XRD analysis suggested that the monoclinic zirconia content was increased by air-abrasion, and decreased by heating. The surface roughness of S10, S20 and H disks was similar. Nevertheless, H groups showed lower bond strengths than the S10 and S20 groups both before and after thermal cycling. Although alumina air-abrasion considerably enhanced bonding between zirconia and indirect composites, subsequent heat treatment had a negative effect on the durability of bond strength.
- 2012-09-01
著者
-
TANOUE Naomi
Nagasaki University Hospital
-
Tanoue Naomi
Nagasaki Univ. Hospital Nagasaki Jpn
-
Tanoue Naomi
Division Of General Dentistry Nagasaki University Hospital
-
Shimoe Saiji
Division Of Oral Health Sciences Hiroshima University Graduate School Of Biomedical Sciences
-
Satoda Takahiro
Division Of Oral Health Sciences Hiroshima University Graduate School Of Biomedical Sciences
-
Okazaki Masayuki
Department Of Biomaterial Science Division Of Molecular Medical Science Hiroshima University Graduat
-
Shimoe Saiji
Department Of Anatomy And Functional Restorations Division Of Oral Health Sciences Hiroshima University Graduate School Of Biomedical Sciences
-
Kusano Kenta
Department Of Anatomy And Functional Restorations Division Of Oral Health Sciences Hiroshima University Graduate School Of Biomedical Sciences
-
Satoda Takahiro
Department Of Anatomy And Functional Restorations Division Of Oral Health Sciences Hiroshima University Graduate School Of Biomedical Sciences
関連論文
- Effects of high-dose major components in oral disinfectants on the cell cycle and apoptosis in primary human gingival fibroblasts in vitro
- Effect of preliminary irradiation on the bond strength between a veneering composite and alloy
- Evaluation of single liquid primers with organic sulfur compound for bonding between indirect composite material and silver-palladium-copper-gold alloy
- Effects of Monomer Composition and Original Filler Content on Filler Loading in the Resulting Centrifuged Composites
- Creation of highly functional CO_3Ap-collagen scaffold biomaterials
- Effect of alumina air-abrasion on mechanical bonding between an acrylic resin and casting alloys
- Apoptotic and Necrotic Influence of Dental Resin Polymerization Initiators in Human Gingival Fibroblast Cultures
- Bond Strength to Primed Ti-6Al-7Nb Alloy of Two Acrylic Resin Adhesives
- Color Stability of Acrylic Resin Adhesives with Different Initiation Modes
- Chemical analyses of hydroxyapatite formation on SAM surfaces modified with COOH, NH_2, CH_3, and OH functions
- Analysis of Chemical Interaction of 4-MET with Hydroxyapatite Using XPS
- Effect of Presilanization Filler Decontamination on Aesthetics and Degradation Resistance of Resin Composites
- Comparative Evaluation of Thione and Phosphate Monomers on Bonding Gold Alloy and Ti-6Al-7Nb Alloy with Tri-n-butylborane initiated Resin
- Effect of Metal Priming Agents on Bond Strength of Resin-modified Glass Ionomers Joined to Gold Alloy
- Effect of single-liquid priming agents on adhesive bonding to aluminum oxide of a methacrylic resin.
- Relation between Attractive Force and Keeper Surface Characteristics of Iron-neodymium-boron Magnetic Attachment Systems
- Effect of a Metal Priming Agent on Wear Resistance of Gold Alloy-indirect Composite Joint
- Properties of an Indirect Composite Material Polymerized with Two Different Laboratory Polymerizing Systems
- A New Laboratory Polymerizing Apparatus Equipped with Halogen and Metal Halide Light Sources
- A Nine-year Follow-up of a Porcelain Laminate Veneer Restoration Applied to an Adolescent with Traumatized Dentition : A Clinical Report
- International telephone code used for citizenship identification in a denture
- Influence of Centrifugal Force on Filler Loading of Resin Composites
- Twenty-four Hour Bond Strength Between Layers of a Highly Loaded Indirect Composite
- Immobilization of Octadecyl Ammonium Chloride on the Surface of Titanium and Its Effect on Microbial Colonization In Vitro
- Effectiveness of Bonding Systems on Bonding Durability of a Prefabricated Porcelain Material
- Synthetic Osteopontin-derived Peptide SVVYGLR can Induce Neovascularization in Artificial Bone Marrow Scaffold Biomaterials
- Role of Acidic Amino Acid for Regulating Hydroxyapatite Crystal Growth
- Advantages of TOF-SIMS Analysis of Hydroxyapatite and Fluorapatite in Comparison with XRD, HR-TEM and FT-IR
- Osteopontin-derived Peptide SVVYGLR Induces Angiogenesis In Vivo
- New Type Scaffold Biomaterials with Magnesium Accelerating Osteoblast Adhesion and Bone Formation
- Morphological and Crystallographic Properties of Tooth Enameloid of Medaka (Oryzias latipes)
- Influence of Laboratory Light-curing Unit Variation on Properties of Prosthetic Composites
- Degree of immobilization of synthetic RGDS(PO_3H_2)PA peptides on titanium surfaces
- SEM Observation of Collagen Fibrils Secreted from the Body Surface of Osteoblasts on a CO_3apatite-collagen Sponge
- Bone formation ability of carbonate apatite-collagen scaffolds with different carbonate contents
- Estrogenic Activity of Phthalate Esters by In Vitro VTG Assay Using Primary-cultured Xenopus Hepatocytes
- Change in Microstructure and Solubility Improvement of HAp Ceramics by Heat-Treatment in a Vacuum
- Osteoblast Proliferation Behavior and Bone Formation on and in CO_3apatite-Collagen Sponges with a Porous Hydroxyapatite Frame
- Studies on Laser Applications to Dental Hard Tissues
- Development of Biomedical Materials Carrying Immobilized Functional Peptides and Discovery of an Angiogenic Peptide
- Detailed Consideration of Physicochemical Properties of CO_3apatites as Biomaterials in Relation to Carbonate Content Using ICP, X-ray Diffraction, FT-IR, SEM, and HR-TEM
- Evaluation of two dual-functional primers and a tribochemical surface modification system applied to the bonding of an indirect composite resin to metals
- Acceleration of bone formation with BMP2 in frame-reinforced carbonate apatite-collagen sponge scaffolds
- Immobilization of Simulated Reducing Agent at the Surface of SiO_2 Fillers in Dental Composite Resins
- The sites of origin and termination of afferent and efferent components in the lingual and pharyngeal branches of the glossopharyngeal nerve in the Japanese monkey (Macaca fuscata)
- An anterograde-retrograde labeling study of the carotid sinus nerve of the Japanese monkey (Macaca fuscata)
- Cell Adhesion and Proliferation Patterns on Mixed Self-assembled Monolayers Carrying Various Ratios of Hydroxyl and Methyl Groups
- Higher Concentrations of Fluoride Ions Dramatically Inhibit the Survival of Osteoblasts
- Current bonding systems for resin-bonded restorations and fixed partial dentures made of silver-palladium-copper-gold alloy
- Influence of laboratory light sources on the wear characteristics of indirect composites
- A novel glass ionomer cement containing MgCO_3 apatite induced the increased proliferation and differentiation of human pulp cells in vitro
- Influence of air-abrasion and subsequent heat treatment on bonding between zirconia framework material and indirect composites
- Properties of indirect composites reinforced with monomer-impregnated glass fiber
- A nine-year clinical case study of a resin-bonded fixed partial denture seated on the maxillary anterior teeth.
- Evaluation of a newly developed polymethyl methacrylate powder for brush-dip technique