Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions
スポンサーリンク
概要
- 論文の詳細を見る
This study investigated the corrosion properties of ion implanted nickel-titanium wire (Neo Sentalloy Ionguard) in artificial saliva and fluoride mouth rinse solutions (Butler F Mouthrinse, Ora-Bliss). Non ion implanted nickel-titanium wire (Neo Sentalloy) was used as control. The anodic corrosion behavior was examined by potentiodynamic polarization measurement. The surfaces of the specimens were examined with SEM. The elemental depth profiles were characterized by XPS. Neo Sentalloy Ionguard in artificial saliva and Butler F Mouthrinse (500 ppm) had a lower current density than Neo Sentalloy. In addition, breakdown potential of Neo Sentalloy Ionguard in Ora-Bliss (900 ppm) was much higher than that of Neo Sentalloy although both wires had similar corrosion potential in Ora-Bliss (450 and 900 ppm). The XPS results for Neo Sentalloy Ionguard suggested that the layers consisted of TiO2 and TiN were present on the surface and the layers may improve the corrosion properties.
- 2010-01-01
著者
-
IIJIMA Masahiro
Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Sch
-
YUASA Toshihiro
Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Sch
-
ENDO Kazuhiko
Division of Biomaterials and Bioengineering, Department of Oral Rehabilitation, School of Dentistry,
-
MUGURUMA Takeshi
Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Sch
-
OHNO Hiroki
Division of Biomaterials and Bioengineering, Department of Oral Rehabilitation, School of Dentistry,
-
MIZOGUCHI Itaru
Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Sch
-
飯嶋 雅弘
北医療大・歯・矯正
-
飯島 雅弘
北海道医療大学歯学部口腔構造・機能発育学系歯科矯正学分野
-
飯嶋 雅弘
北海道医療大学歯学部口腔構造・機能発育学系 歯科矯正学分野
-
Endo Kazuhiko
Division Of Biomaterials And Bioengineering Department Of Oral Rehabilitation School Of Dentistry He
-
Endo Kazuhiko
Silicon Systems Research Laboratories Nec Corporation
-
Endo Kazuhiko
Department Of Dental Materials Science School Of Dentistry Health Science University Of Hokkaido
-
Ohno Hiroki
北海道医療大学 歯学部歯科矯正学
-
Ohno H
Division Of Biomaterials And Bioengineering Department Of Oral Rehabilitation School Of Dentistry He
-
Ohno Hiroki
Division Of Biomaterials And Bioengineering Department Of Oral Rehabilitation School Of Dentistry He
-
Yuasa Toshihiro
Division Of Orthodontics And Dentofacial Orthopedics Department Of Oral Growth And Development Schoo
-
Mizoguchi I
Division Of Orthodontics And Dentofacial Orthopedics Department Of Oral Growth And Development Schoo
-
Iijima Masahiro
Division Of Orthodontics And Dentofacial Orthopedics Department Of Oral Growth And Development Schoo
-
Muguruma Takeshi
Division Of Orthodontics And Dentofacial Orthopedics Department Of Oral Growth And Development Schoo
関連論文
- A-7 ポルトランドセメント配合レジンの石灰化誘導能(陶材・生体用セラミックス・模型材,一般講演(口頭発表))
- Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions
- P-40 バイオガラス配合レジンによる石灰化誘導能(生体用セラミックス1,一般講演(ポスター発表),第54回日本歯科理工学会学術講演会)
- A-7 ポルトランドセメント配合レジンの石灰化誘導能(陶材・生体用セラミックス・模型材,一般講演(口頭発表),第55回日本歯科理工学会学術講演会)
- A-13 シリカ系微粒子を含むレジンの石灰化誘導能(生体用セラミックスIII,一般講演(口頭発表),第56回日本歯科理工学会学術講演会)
- ポルトランドセメント配合レジンの石灰化誘導能
- Localization of human β-defensin 3 mRNA in normal oral epithelium, leukoplakia, and lichen planus : an in situ hybridization study
- 矯正用金属製装置の異種金属接触腐食挙動に関する研究 : 生理食塩水中における腐食電位の測定
- 矯正用チタン系材料におけるレーザー溶接法の基礎的研究と臨床応用(最近のトピックス)
- 矯正用ミニスクリューインプラントの撤去トルクと破断トルクの関係(最近のトピックス)
- 外科的矯正治療患者における手術前後の口腔内管理について(北海道医療大学歯学会第25回学術大会 一般講演抄録)
- An Immunohistochemical Study of the Localization of Biglycan, Decorin and Large Chondroitin-sulphate Proteoglycan in Pleomorphic Adenoma
- Effects of application time and agitation for bonding orthodontic brackets with two self-etching primer systems
- Bond Strength Comparison and Scanning Electron Microscopic Evaluation of Three Orthodontic Bonding Systems
- P-64 生体模擬環境下でチタンおよびチタン合金の表面に生成する不動態皮膜の半導体的性質と保護性(金属,一般講演(ポスター発表),第48回日本歯科理工学会学術講演会)
- A-2 擬似体液中でNi-Ti合金表面に生成する不動態皮膜の構造と保護性に及ぼすタンパク質の影響(腐食,一般講演(口頭発表),第47回日本歯科理工学会学術講演会・総会)
- タンパク質を含む擬似体液中におけるNi-Ti合金の腐食機構(腐食, 平成17年度秋期 (長崎) 第46回日本歯科理工学会学術講演会)
- 交流インピーダンス法を用いたNi-Ti合金の生体模擬環境下における腐食機構解析
- 42.超弾性NiTi合金ワイヤーの耐食性に及ぼす第三元素の影響(一般講演)(東日本歯学会第14回学術大会(平成8年度総会))
- B-23 Cuを添加したNi-Ti合金の表面構造と腐食挙動
- 13.Cuを含有した矯正用Ni-Ti合金ワイヤーの曲げ特性と相変態(一般講演)(東日本歯学会第13回学術大会(平成7年度総会))
- PJ-125 Workplace Hypertension is Associated with Obesity and High Normal Blood Pressures at the Physical Checkup(Preventive medicine/Epidemiology/Education-7 (H) PJ21,Poster Session (Japanese),The 70th Anniversary Annual Scientific Meeting of the Japanese
- 18.矯正用卑金属合金ワイヤーの生理的食塩水中における腐食挙動(東日本歯学会第17回学術大会)
- 4.ブラケット裏面処理とディボンディングの容易さの関連性(一般講演)(東日本歯学会第12回学術大会(平成6年度総会))
- 矯正用金属材料の異種金属接触腐食挙動
- Hydroxyapatite Film Coating by Thermally Induced Liquid-phase Deposition Method for Titanium Implants
- Mechanism by which Porous Structure is Formed on the Surface of Gold Alloy Containing Only Cu as Base Metal
- Suppression of Charges in Al_2O_3 Gate Dielectric and Improvement of MOSFET Performance by Plasma Nitridation(High-κ Gate Dielectrics)
- Suppression of Charges in Al_2O_3 Gate Dielectric and Improvement of MOSFET Performance by Plasma Nitridation
- Application of Fluorinated Amorphous Carbon Thin Films for Low Dielectric Constant Interlayer Dielectrics
- Wear of opposing teeth by posterior composite resins : Evaluation of newly developed wear test methods
- Effect of dentinal water on bonding of self-etching adhesives
- In Vitro Corrosion of Dental Ag-based Alloys in Polyvinylpyrrolidone Iodine Solution
- In Vitro Corrosion Characteristics of Commercially Available Orthodontic Wires
- Corrosion Behavior and Surface Structure of Orthodontic Ni-Ti Alloy Wires
- Corrosion Characteristics of Ferric and Austenitic Stainless Steels for Dental Magnetic Attachment
- Corrosion Resistance and Biocompatibility of High Nitrogen-bearing Stainless Steels
- Effect of Cr and Cu Addition on Corrosion Behavior of Ni-Ti Alloys
- An Immunohistochemical Study of the Localization of Types I, II and III Collagen in the Temporomandibular Joint of Growing Monkeys
- Application of Plasma Immersion Ion Implantation for Surface Modification of Nickel-titanium Rotary Instruments
- Gold Alloys for Resin Bonding including Small Amount Base Metals : Structural Changes of Alloy Surface by the High-temperature Oxidation
- A review : Biodegradation of resin-dentin bonds
- Bending and torsional properties of commercial nickel-titanium orthodontic wires
- 骨格型下顎前突症における骨格性非対称の形態学的特徴 : 正面頭部X線規格写真での検討
- 上顎前方牽引装置の治療効果 : Wits分析とそれに関連する要因への影響
- 上顎前方牽引装置の治療に伴う形態変化について : Wits分析とそれに関連する要因の検討(一般講演抄録,第39回北海道矯正歯科学会大会)
- Transformation behavior of nickel-titanium orthodontic wires under tensile load
- 骨格性III級症例の顎整形治療が成長に及ぼす長期的影響について
- 10. 双生児にcombined headgearとhigh-pull headgearを用いて治療した報告(一般口演,第43回北海道矯正歯科学会大会)
- 骨格型上顎前突症におけるcombined bionator-headgear applianceとhigh-pull headgearの治療効果 : 双生児における比較検討
- Metal Organic Atomic Layer Deposition of High-$k$ Gate Dielectrics Using Plasma Oxidation
- 骨格性反対咬合症例に対する上顎前方牽引治療後の術後変化(一般講演抄録,第38回北海道矯正歯科学会大会)
- 上顎前方牽引治療の術後変化とその要因
- III級ゴムの治療効果について
- 口呼吸・鼻疾患が不正咬合者の顎態の成長発育に及ぼす影響について(一般講演抄録,第35回北海道矯正歯科学会大会)
- 口呼吸および鼻疾患が不正咬合者の顎態に及ぼす影響について
- 1. 矯正患者におけるエナメル質の脱灰とそのリスクファクター(一般口演,第49回北海道矯正歯科学会大会)
- 6. セルフエッチングシステムによるブラケットの接着特性と歯質への影響(一般口演,第48回北海道矯正歯科学会大会)
- 5. 市販ミニインプラントのねじり特性と曲げ疲労特性(一般口演,第48回北海道矯正歯科学会大会)
- 1. 上顎第一大臼歯の前後的位置と顎顔面骨格形態との関連性(一般口演,第48回北海道矯正歯科学会大会)
- 5. 矯正用金属製装置の異種金属接触腐食挙動(一般口演,第47回北海道矯正歯科学会大会)
- 6. Ti系矯正用金属材料の接合法について(一般口演,第46回北海道矯正歯科学会大会)
- Controlling Fluorine Concentration of Fluorinated Amorphous Carbon Thin Films for Low Dielectric Constant Interlayer Dielectrics
- Laser welding investigation of orthodontic titanium-based wires
- 不正咬合の簡便な難易度の評価法について(一般講演抄録,第34回北海道矯正歯科学会大会)
- Minimization of Gate-Induced Drain Leakage by Controlling Gate Underlap Length for Low-Standby-Power Operation of 20-nm-Level Four-Terminal Silicon-on-Insulator Fin-Shaped Field Effect Transistor
- 13.[figure]先天欠如を伴うアングルI級症例(症例展示抄録,第38回北海道矯正歯科学会大会)
- 10.下顎左側偏位を伴う上下顎前突症例(症例展示抄録,第38回北海道矯正歯科学会大会)
- 2. 熱可塑性樹脂製矯正装置の初期矯正力測定(一般口演,第52回北海道矯正歯科学会大会抄録)
- 1. 4種類の矯正用ワイヤーの機械的特性とクワドヘリックス装置の矯正力(一般口演,第52回北海道矯正歯科学会大会抄録)
- A-8 DLC膜をコーティングした純チタンの疑似体液中における腐食挙動(インプラント,一般講演(口頭発表),第60回日本歯科理工学会学術講演会(創立30周年記念大会))
- 7. エナメル質の脱灰抑制に対するCO_2レーザー照射およびフッ化物塗布の効果(一般口演,第53回北海道矯正歯科学会大会抄録)
- P-32 β-Ti歯科矯正用ワイヤーの静的および疲労曲げ特性(金属材料,一般講演(ポスター発表),第61回日本歯科理工学会学術講演会)
- Effects of the addition of fluoride to a 4-META/MMA-TBB-based resin adhesive on fluoride release, acid resistance of enamel and shear bond strength in vitro
- In vitro corrosion of dental Au-based casting alloys in polyvinylpyrrolidone-iodine solution
- Analysis of residual stress in the resin of metal-resin adhesion structures by scanning acoustic microscopy
- DLC膜をコーティングした純チタンの疑似体液中における腐食挙動
- Effects of the addition of fluoride to a 4-META/MMA-TBB-based resin adhesive on fluoride release, acid resistance of enamel and shear bond strength in vitro
- 6. 歯科矯正用アンカースクリューを用いてカムフラージュ治療を行った骨格性III級を呈する2症例(一般口演,第54回北海道矯正歯科学会大会)
- 5. 即時牽引した歯科矯正用アンカースクリュー周囲骨の評価(一般口演,第54回北海道矯正歯科学会大会)
- アンカースクリューの破折について(歯科矯正用アンカースクリュー-現状と未来-,シンポジウム,第54回北海道矯正歯科学会大会)
- Micromorphological cellular responses of MC3T3-E1 and RAW264.7after exposure to water-dispersible silver nanoparticles stabilized by metal-carbon σ-bonds
- Mineralization by Acrylic Resin Containing Portland Cement Powder for Long-term Water Storage Analyzed by SEM, XPS and XRD