An Evaluation of High Acceleration Voltage Electron Beam Writing on X-Ray Masks
スポンサーリンク
概要
- 論文の詳細を見る
High acceleration voltage electron beam (EB) writing on X-ray masks was evaluated. Normalized dose latitudes of 100 keV for the 0.15 µm line and space (L&S), isolated lines and isolated space patterns were 3.5, 2.7 and 7.6 times larger than those of 25 keV, respectively. It was also found that the back-scattered electrons extend over a range of 10 µm in 100 keV writing. The maximum mesh size in the pattern area density method for proximity effect correction was evaluated by Monte Carlo simulation. When a ±10% pattern size error was permitted for a 0.1 µm line pattern, the 0.3 µm mesh size in 50 keV writing was markedly improved to 5 µm at a higher voltage of 100 keV. Reducing the beam size by half from 60 nm (2σ) in 100 keV writing also increases the mesh size from 0.4 to 5 µm. Moreover, the fine W–Ti patterns of 0.06–0.14 µm were formed using 100 keV Gaussian EB writing and electron cyclotron resonance (ECR) etching systems, where good linearity and linewidth deviations within 9 nm (3σ) were obtained.
- 1998-05-15
著者
-
KITAMURA Kaeko
Advanced Technology R&D Center, Mitsubishi Electric Corporation
-
Aya Sunao
Advanced Technology R&d Center Mitsubishi Electric Corporation
-
Yabe Hideki
Advanced Technology R&d Center Mitsubishi Electric Corporation
-
Marumoto Kenji
Advanced Technology R&d Center Mitsubishi Electric Corporation
-
Kise Koji
Advanced Technology R&d Center Mitsubishi Electric Corporation
-
Yabe Hideki
Advanced Technology R&D Center, Mitsubishi Electric Corporation,
-
Kitamura Kaeko
Advanced Technology R&D Center, Mitsubishi Electric Corporation,
-
Aya Sunao
Advanced Technology R&D Center, Mitsubishi Electric Corporation,
-
Kise Koji
Advanced Technology R&D Center, Mitsubishi Electric Corporation,
-
Kitamura Kaeko
Advanced Technology R&D Center, Mitsubishi Electric Corporation
関連論文
- A Principle of Deposition of Ultra Low and Uniform Stress Absorber for X-Ray Mask
- Analysis of Overlay Accuracy in 0.14μm Device Fabrication using Synchrotron Radiation Lithography
- Evaluation of Acid Diffusibility in a Chemical Amplification Resist Using Acidic Water-Soluble Film
- Pattern Resolution in X-ray Lithography Using Pattern Replication Technique on a Mask
- 50 nm Pattern Printing by Narrowband Proximity X-Ray Lithography
- A New Cleaning Technique for X-Ray Masks in Alkaline Solutions by Direct Control of Electrochemical Potential
- Proximity Effect Correction for 1:1 X-Ray Mask Fabrication
- Stress Stability of W-Ti X-Ray Absorber in Patterning Process
- An Evaluation of High Acceleration Voltage Electron Beam Writing on X-Ray Masks
- Validity of Double and Triple Gaussian Functions for Proximity Effect Correction in X-ray Mask Writing
- Influence of Optical Parameters of Synchrotron Radiation Lithography Beamline on Pattern Replication
- Electron Beam Writing Techniques for Fabricating Highly Accurate X-Ray Masks
- Control of X-Ray Beam Fluctuation in Synchrotron Radiation Lithography Beamline
- An Ultralow Stress Ta_4B Absorber for X-Ray Masks
- Estimation of Trabecular Bone Axis for Characterization of Cancellous Bone Using Scattered Ultrasonic Wave
- Ultrasonic Scattering Study of Cancellous Bone for Osteoporosis Diagnosis
- Transport Properties of a Resistively-Coupled Single-Electron Transistor
- Transport Properties of a Resistively-Coupled Single-Electron Transistor
- Transport Properties of Resistively-Coupled Single-Electron Transistor
- An Evaluation of High Acceleration Voltage Electron Beam Writing on X-Ray Masks
- Theoretical Analysis on Mechanical Deformation of Membrane-Based Photomask Blanks
- High Aspect Pattern Fabrication by Nano Imprint Lithography Using Fine Diamond Mold
- A Principle of Deposition of Ultra Low and Uniform Stress Absorber for X-Ray Mask