A frequency-tuning method in the microwave region, which maintains a high unloaded Q-factor, was demonstrated using a double-sapphire-loaded cavity which operates on the Whispering Gallery mode, WGH_<9,1,0>. Two adjacent nominally identical sapphire cylinders were positioned in a copper cavity and tuned by changing their relative coupling. A frequency tuning range of 85 MHz and a maximum unloaded Q-factor of 1.3 × 10^5 was experimentally measured at room temperature. This is only 13% less than the single resonator Q-factor, which is a small compromise to pay for the increased tuning capacity.
- 社団法人電子情報通信学会の論文
- 2003-07-01
著者
-
Ikegami T
Aist
-
Ikegami Takeshi
National Metrology Institute Of Japan (nmij)/national Institute Of Advanced Industrial Science And T
-
Ohshima Shin-ichi
National Metology Institute Of Japan
-
Ohshima Shin-ichi
Time Standards Section Time And Freqency Division National Metrololgy Institute Of Japan Aist
-
Watabe Ken-ichi
National Metology Institute Of Japan
-
HARTNETT John
National Metology Institute of Japan
-
HARTNETT John
School of Physics, The University of Western Australia
-
Ikegami Takeshi
Time Standards Section Time And Freqency Division National Metrololgy Institute Of Japan Aist
-
Ikegami Takeshi
National Metology Institute Of Japan/aist
関連論文
- Optical Frequency Measurement Using Chirped-Mirror-Dispersion-Controlled Mode-Locked Ti:Al_2O_3 Laser
- Characteristics of Optical Propagation through Rain for Infrared Space Communications
- Development of an Optically Pumped Cs Frequency Standard at the NRLM
- The Optically Pumped Cs Frequency Standard at the NRLM
- Spectral Width of Saturated Absorption Spectra of Cs with a Laser Diode
- Measurement and Analysis of the Atomic Velocity Distribution and the Second-Order Doppler Shift of the Cesium Beam Frequency Standard, NRLM-II
- Velocity Distribution by Time-of-Flight Measurement in an Optically Pumped Cs Beam Frequency Standard
- Continuous-wave RbTiOAsO_4Optical Parametric Oscillator in Optical Frequency Interval Divider Scheme
- Influence of Electrochromic Damage of a KTiOPO_4 Crystal on a Phase-Locked CW Optical Parametric Oscillator
- Long Term Operation of a CW Doubly Resonant Optical Parametric Oscillator
- Accuracy of an Optical Parametric Oscillator as an Optical Frequency Divider
- A low threshold and stable optical parametric oscillator for optical frequency division
- Development of an Intensity Stabilized Laser System with Frequency Offset of 9.2 GHz
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Cesium Atomic Fountain with Two-Dimensional Moving Molasses
- Cryogenic Whispering Gallery Sapphire Oscillator for Microwave Frequency Standard Applications(Microwaves, Millimeter-Waves)
- Tunable Double-Sapphire-Loaded Microwave Cavity with High-Q Factor(Microwaves, Millimeter-Waves)
- Generation of Uniform Magnetic Field for Cs Fountain Frequency Standard
- Optical frequency link between an acetylene stabilized laser at 1542 nm and an Rb stabilized laser at 778 nm using a two-color mode-locked fiber laser
- Frequency Stabilization of Laser Diodes to the Cs-D_2 Line with the Zeeman Modulation Method
- Differential Temperature Controller for Stable Temperature Control of a Nonlinear Optical Crystal at Approximately 200℃
- Cryogenic-Sapphire-Oscillator-Based Reference Signal at 1 GHz with $10^{-15}$ Level Instability
- Short Term Frequency Stability Tests of Two Cryogenic Sapphire Oscillators
- Reference Signal Synthesized from a Cryogenic Sapphire Oscillator Improved by Power Control Servo
- Microwave Local Oscillator for a Cesium Frequency Standard Synthesized from a Cryogenic Sapphire Oscillator
- Signal with Flat Phase Noise Using a Carrier and the Power Spectral Density of White Noise for Phase Noise Standards
- Numerical Simulation of Distributed Cavity Phase Shift in Atomic Fountain Frequency Standard
- Angular Distribution Measurement of Cesium Atomic Beam from Long Tube Collimators
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation