Cesium Atomic Fountain with Two-Dimensional Moving Molasses
スポンサーリンク
概要
- 論文の詳細を見る
In this paper we describe a cesium atomic fountain with two-dimensional moving molasses. This method is applicable for multipulse operation of the cesium atomic fountain frequency standard, which will improve the frequency stability and reduce the frequency shift due to spin exchange collisions of atomic fountain frequency standards. Multipulse launching is demonstrated experimentally, and the frequency shift due to the fluorescent light from the loaded atoms is estimated.
- 社団法人応用物理学会の論文
- 1995-09-01
著者
-
Ikegami T
Aist
-
Ikegami Takeshi
National Research Laboratory Of Metrology
-
Ikegami Takeshi
National Metrology Institute Of Japan (nmij)/national Institute Of Advanced Industrial Science And T
-
Ohshima Shin-ichi
National Research Laboratory Of Metrology
-
Ohshima Shin-ichi
National Metology Institute Of Japan
-
Ohshima Shin-ichi
Time Standards Section Time And Freqency Division National Metrololgy Institute Of Japan Aist
-
NAKADAN Yasuhiro
National Research Laboratory of Metrology
-
KUROSU Takayuki
National Metrology Institute of Japan AIST
-
Kurosu Takayuki
Time Standards Section Time And Freqency Division National Metrololgy Institute Of Japan Aist
-
Kurosu Takayuki
National Metrology Institute Of Japan (nmij)/aist
-
Ikegami Takeshi
Time Standards Section Time And Freqency Division National Metrololgy Institute Of Japan Aist
-
Ikegami Takeshi
National Metology Institute Of Japan/aist
関連論文
- Optical Frequency Measurement Using Chirped-Mirror-Dispersion-Controlled Mode-Locked Ti:Al_2O_3 Laser
- Development of an Optically Pumped Cs Frequency Standard at the NRLM
- The Optically Pumped Cs Frequency Standard at the NRLM
- Spectral Width of Saturated Absorption Spectra of Cs with a Laser Diode
- Measurement and Analysis of the Atomic Velocity Distribution and the Second-Order Doppler Shift of the Cesium Beam Frequency Standard, NRLM-II
- Velocity Distribution by Time-of-Flight Measurement in an Optically Pumped Cs Beam Frequency Standard
- Continuous-wave RbTiOAsO_4Optical Parametric Oscillator in Optical Frequency Interval Divider Scheme
- Influence of Electrochromic Damage of a KTiOPO_4 Crystal on a Phase-Locked CW Optical Parametric Oscillator
- Long Term Operation of a CW Doubly Resonant Optical Parametric Oscillator
- Accuracy of an Optical Parametric Oscillator as an Optical Frequency Divider
- A low threshold and stable optical parametric oscillator for optical frequency division
- Measurement of a Weak Magnetic Field Using Cold Atoms : Atoms, Molecules, and Chemical Physics
- Velocity Selective Absorption by a Long Lifetime Transition in a Ca Atomic Beam
- Development of an Intensity Stabilized Laser System with Frequency Offset of 9.2 GHz
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Cesium Atomic Fountain with Two-Dimensional Moving Molasses
- Cryogenic Whispering Gallery Sapphire Oscillator for Microwave Frequency Standard Applications(Microwaves, Millimeter-Waves)
- Tunable Double-Sapphire-Loaded Microwave Cavity with High-Q Factor(Microwaves, Millimeter-Waves)
- Generation of Uniform Magnetic Field for Cs Fountain Frequency Standard
- Optical frequency link between an acetylene stabilized laser at 1542 nm and an Rb stabilized laser at 778 nm using a two-color mode-locked fiber laser
- Frequency Stabilization of Laser Diodes to the Cs-D_2 Line with the Zeeman Modulation Method
- Differential Temperature Controller for Stable Temperature Control of a Nonlinear Optical Crystal at Approximately 200℃
- Improvement of the Frequency Stability of the Cs Frequency Standard NRLM-I
- Cryogenic-Sapphire-Oscillator-Based Reference Signal at 1 GHz with $10^{-15}$ Level Instability
- Short Term Frequency Stability Tests of Two Cryogenic Sapphire Oscillators
- Reference Signal Synthesized from a Cryogenic Sapphire Oscillator Improved by Power Control Servo
- Microwave Local Oscillator for a Cesium Frequency Standard Synthesized from a Cryogenic Sapphire Oscillator
- Signal with Flat Phase Noise Using a Carrier and the Power Spectral Density of White Noise for Phase Noise Standards
- Numerical Simulation of Distributed Cavity Phase Shift in Atomic Fountain Frequency Standard
- High-Sensitive Spectroscopy of Molecular Iodine by Means of Power-Stabilized Light from a Diode Laser Spectrometer
- Angular Distribution Measurement of Cesium Atomic Beam from Long Tube Collimators
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation