Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation
スポンサーリンク
概要
- 論文の詳細を見る
For the dual-mixer time-difference method using the discrete Fourier transformation, the formulation of the truncation error to determine the time difference between two oscillators is derived. It is found that serious error occurs due to the truncation error with a larger frequency difference between two oscillators. The condition of the discrete Fourier transformation to determine the frequency difference between two oscillators with sufficiently high accuracy for atomic clocks is obtained.
- The Japan Society of Applied Physicsの論文
- 2013-03-25
著者
-
Ikegami Takeshi
National Metology Institute Of Japan/aist
-
Yanagimachi Shinya
National Metrology Institute of Japan (NMIJ), AIST, Tsukuba, Ibaraki 305-8563, Japan
-
Hagimoto Ken
National Metrology Institute of Japan (NMIJ), AIST, Tsukuba, Ibaraki 305-8563, Japan
関連論文
- Optical Frequency Measurement Using Chirped-Mirror-Dispersion-Controlled Mode-Locked Ti:Al_2O_3 Laser
- Continuous-wave RbTiOAsO_4Optical Parametric Oscillator in Optical Frequency Interval Divider Scheme
- Influence of Electrochromic Damage of a KTiOPO_4 Crystal on a Phase-Locked CW Optical Parametric Oscillator
- Long Term Operation of a CW Doubly Resonant Optical Parametric Oscillator
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Cesium Atomic Fountain with Two-Dimensional Moving Molasses
- Cryogenic Whispering Gallery Sapphire Oscillator for Microwave Frequency Standard Applications(Microwaves, Millimeter-Waves)
- Tunable Double-Sapphire-Loaded Microwave Cavity with High-Q Factor(Microwaves, Millimeter-Waves)
- Frequency Stabilization of Laser Diodes to the Cs-D_2 Line with the Zeeman Modulation Method
- Cryogenic-Sapphire-Oscillator-Based Reference Signal at 1 GHz with $10^{-15}$ Level Instability
- Short Term Frequency Stability Tests of Two Cryogenic Sapphire Oscillators
- Reference Signal Synthesized from a Cryogenic Sapphire Oscillator Improved by Power Control Servo
- Microwave Local Oscillator for a Cesium Frequency Standard Synthesized from a Cryogenic Sapphire Oscillator
- Signal with Flat Phase Noise Using a Carrier and the Power Spectral Density of White Noise for Phase Noise Standards
- Numerical Simulation of Distributed Cavity Phase Shift in Atomic Fountain Frequency Standard
- Angular Distribution Measurement of Cesium Atomic Beam from Long Tube Collimators
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation