We describe a 1 GHz reference signal with $10^{-15}$ level fractional frequency stability for averaging times longer than 1 s, synthesized from a 10.8 GHz oscillation frequency of a cryogenic-sapphire-resonator-based ultra-stable oscillator and phase locked to a hydrogen maser with a time constant of about 1000 s. The degradation of the short term stability of the reference signal by phase locking to the hydrogen maser was evaluated. We also report on the implementation of the 1 GHz signal down converted to 5 MHz as a reference oscillator for a cesium atomic fountain frequency standard.
- 2008-09-25
著者
-
Ohshima Shin-ichi
National Metology Institute Of Japan
-
Watabe Ken-ichi
National Metology Institute Of Japan
-
HARTNETT John
School of Physics, The University of Western Australia
-
Ikegami Takeshi
National Metology Institute Of Japan/aist
-
Locke Clayton
School of Physics, University of Western Australia, 35 Stirling Hwy, Crawley, WA 6009, Australia
-
Locke Clayton
School of Physics, University of Western Australia, 35 Stirling Hwy, Crawley, Western Australia 6009, Australia
-
Yanagimachi Shinya
National Metrology Institute of Japan (NMIJ), AIST, Tsukuba, Ibaraki 305-8563, Japan
-
Yanagimachi Shinya
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan
-
Santarelli Giorgio
Laboratoire National d'Essais-Système de Références Temps-Espace (LNE-SYRTE), Observatoire de Paris, 61 avenue de l'Observatoire, 75014 Paris, France
-
Takamizawa Akifumi
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan
-
Watabe Ken-ichi
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan
-
Ohshima Shin-ichi
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan
-
Ikegami Takeshi
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan
-
Hartnett John
School of Physics, University of Western Australia, 35 Stirling Hwy, Crawley, Western Australia 6009, Australia
関連論文
- Optical Frequency Measurement Using Chirped-Mirror-Dispersion-Controlled Mode-Locked Ti:Al_2O_3 Laser
- Characteristics of Optical Propagation through Rain for Infrared Space Communications
- Measurement and Analysis of the Atomic Velocity Distribution and the Second-Order Doppler Shift of the Cesium Beam Frequency Standard, NRLM-II
- Velocity Distribution by Time-of-Flight Measurement in an Optically Pumped Cs Beam Frequency Standard
- Continuous-wave RbTiOAsO_4Optical Parametric Oscillator in Optical Frequency Interval Divider Scheme
- Influence of Electrochromic Damage of a KTiOPO_4 Crystal on a Phase-Locked CW Optical Parametric Oscillator
- Long Term Operation of a CW Doubly Resonant Optical Parametric Oscillator
- Development of an Intensity Stabilized Laser System with Frequency Offset of 9.2 GHz
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Cesium Atomic Fountain with Two-Dimensional Moving Molasses
- Cryogenic Whispering Gallery Sapphire Oscillator for Microwave Frequency Standard Applications(Microwaves, Millimeter-Waves)
- Tunable Double-Sapphire-Loaded Microwave Cavity with High-Q Factor(Microwaves, Millimeter-Waves)
- Generation of Uniform Magnetic Field for Cs Fountain Frequency Standard
- Frequency Stabilization of Laser Diodes to the Cs-D_2 Line with the Zeeman Modulation Method
- Cryogenic-Sapphire-Oscillator-Based Reference Signal at 1 GHz with $10^{-15}$ Level Instability
- Short Term Frequency Stability Tests of Two Cryogenic Sapphire Oscillators
- Reference Signal Synthesized from a Cryogenic Sapphire Oscillator Improved by Power Control Servo
- Microwave Local Oscillator for a Cesium Frequency Standard Synthesized from a Cryogenic Sapphire Oscillator
- Signal with Flat Phase Noise Using a Carrier and the Power Spectral Density of White Noise for Phase Noise Standards
- Numerical Simulation of Distributed Cavity Phase Shift in Atomic Fountain Frequency Standard
- Angular Distribution Measurement of Cesium Atomic Beam from Long Tube Collimators
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation