Stabilization of a Laser Diode with an Intracavity Cesium Cell
スポンサーリンク
概要
- 論文の詳細を見る
The frequency of a laser diode (LD) with an intracavity cesium cell was stabilized optically by the nature of the atoms in the cell. The injection current and the position of the reflecting mirror were simultaneously controlled to maintain the optimum condition by modulating the injection current and using the phase sensitive detection. The experimental setup was simple and the linewidth became narrower than 100 kHz.
- 社団法人応用物理学会の論文
- 1997-12-15
著者
-
Ohshima Shin-ichi
National Research Laboratory Of Metrology
-
Ohshima Shin-ichi
National Metology Institute Of Japan
-
Ohshima Shin-ichi
Time Standards Section Time And Freqency Division National Metrololgy Institute Of Japan Aist
-
KOGA Yasuki
National Research Laboratory of Metrology
-
Koga Yasuki
National Metrology Institute Of Japan Aist
-
HAGIMOTO Ken
National Research Laboratory of Metrology
-
AKULSHIN Alexander
Lebedev Physical Institute
-
Hagimoto K
Nagoya Inst. Technol. Nagoya Jpn
-
Koga Yasuki
National Metology Institute Of Japan/aist
-
Koga Yasuki
National Institute of Materials and Chemical Research
-
Hagimoto Ken
National Metrology Institute of Japan (NMIJ), AIST, Tsukuba, Ibaraki 305-8563, Japan
関連論文
- Development of an Optically Pumped Cs Frequency Standard at the NRLM
- The Optically Pumped Cs Frequency Standard at the NRLM
- Spectral Width of Saturated Absorption Spectra of Cs with a Laser Diode
- Measurement and Analysis of the Atomic Velocity Distribution and the Second-Order Doppler Shift of the Cesium Beam Frequency Standard, NRLM-II
- Velocity Distribution by Time-of-Flight Measurement in an Optically Pumped Cs Beam Frequency Standard
- Spectral Profiles of Cs-D Lines
- Absorption of Rb-D Limes by Rb Filter Cell
- Spectral Profiles of Rb-D Lines
- Continuous-wave RbTiOAsO_4Optical Parametric Oscillator in Optical Frequency Interval Divider Scheme
- Influence of Electrochromic Damage of a KTiOPO_4 Crystal on a Phase-Locked CW Optical Parametric Oscillator
- Long Term Operation of a CW Doubly Resonant Optical Parametric Oscillator
- Accuracy of an Optical Parametric Oscillator as an Optical Frequency Divider
- A low threshold and stable optical parametric oscillator for optical frequency division
- Measurement of a Weak Magnetic Field Using Cold Atoms : Atoms, Molecules, and Chemical Physics
- Spatial Profiles of a Deflected Cesium Atomic Beam
- Development of an Intensity Stabilized Laser System with Frequency Offset of 9.2 GHz
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Stabilization of a Laser Diode with an Intracavity Cesium Cell
- Cesium Atomic Fountain with Two-Dimensional Moving Molasses
- Solution Growth of CuGaS_2 Using In as a Solvent under Controlled S Vapor Pressure
- Cryogenic Whispering Gallery Sapphire Oscillator for Microwave Frequency Standard Applications(Microwaves, Millimeter-Waves)
- Tunable Double-Sapphire-Loaded Microwave Cavity with High-Q Factor(Microwaves, Millimeter-Waves)
- Generation of Uniform Magnetic Field for Cs Fountain Frequency Standard
- Frequency Stabilization of Laser Diodes to the Cs-D_2 Line with the Zeeman Modulation Method
- Construction of an Improved Cesium Frequency Standard (NRLM-II)
- Improvement of the Frequency Stability of the Cs Frequency Standard NRLM-I
- Cryogenic-Sapphire-Oscillator-Based Reference Signal at 1 GHz with $10^{-15}$ Level Instability
- Short Term Frequency Stability Tests of Two Cryogenic Sapphire Oscillators
- Reference Signal Synthesized from a Cryogenic Sapphire Oscillator Improved by Power Control Servo
- Microwave Local Oscillator for a Cesium Frequency Standard Synthesized from a Cryogenic Sapphire Oscillator
- An Improved Method of Measuring the Zeeman Shift in Cesium Beam Frequency Standards
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation
- Analysis of Truncation Error for Dual-Mixer Time-Difference Measurement System Using Discrete Fourier Transformation