タイロンを用いる微量チタン(IV)のメンブランフィルター予備濃縮 : 吸光光度定量
スポンサーリンク
概要
- 論文の詳細を見る
A simple and rapid preconcentation technique, based on collecting trace elements on a membrane filter and dissolving the membrane filter with them in an organic solvent, has been applied to the spectrophotometric determination of titanium (IV). Titanium (IV), 0.5〜10μg in 30〜500 ml of sample solution, is collected as titanium (IV)/Tiron/Zephiramine ion pair on a polyethersulfone membrane filter, the membrane filter with the ion pair is dissolved in 5 ml of dimethylsulfoxide (DMSO), and the absorbance of the DMSO solution is measured at 382 nm against a reagent blank. A calibration graph is linear over the range 0.50〜10.0μg of titanium (IV) in 5 ml of the final DMSO solution. The molar absorptivity is 1.45×10^4l mol^<-1>cm^<-1>. Six replicate determinations for a sample containing 10.0μg of titanium (IV) give a mean absorbance of 0.606 with a relative standard deviation of 2.1%. The detection limit, defined as three times the standard deviation of the reagent blank, is 0.1μg l^<-1> of titanium with 100-fold preconcentration. Fe (III), V (V), Mo (VI) and W (VI) interfere, but Fe (III) is masked with EDTA.
- 社団法人日本分析化学会の論文
- 1993-09-05
著者
関連論文
- 山形県米沢市における降水中の主要イオン成分の経年変化
- Seasonal Variation of Sulfur Isotope Ratios of Non-Sea Salt Sulfate in Wet Deposits in Northern Part of Japan
- 降水に含まれる無機成分の化学的特徴(第六報)
- アルギン酸固定化水和酸化チタンへの各種リン酸イオンの吸着
- 降水に含まれる無機成分の化学的特徴(第五報)
- 均一粒径イオン交換樹脂直接挿入/黒鉛炉原子吸光法によるガリウムの定量
- 山形県米沢市の湿性降下物に含まれる硫酸イオンの起源
- 山形県における降水の化学的および地域的特徴
- 降水に含まれる無機成分の化学的特徴(第四報)
- タイロンを用いる微量チタン(IV)のメンブランフィルター予備濃縮 : 吸光光度定量