Measurement of Reaction Current during Atomic Force Microscope Local Oxidation of Conductive Surfaces Capped with Insulating Layers
スポンサーリンク
概要
- 論文の詳細を見る
A local oxidation technique using an atomic force microscope (AFM) was studied. The reaction current passing through the AFM tip was measured in order to evaluate its dependence on the resistivity and surface condition of the samples. The current efficiency actually contributing the oxidation reaction was about 0.5 for a Si substrate. The ratio was constant regardless of the tip scan speed. As for NiFe thin films, the current was higher and the current efficiency was lower than those of the Si substrate. The Al2O3 capped layer on the NiFe thin films reduced the excess current, which did not contribute to the oxidation.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2008-01-25
著者
-
TAKEMURA Yasushi
Department of Electrical and Computer Engineering, Yokohama National University
-
Shimada Yasuyuki
Department Of Cardiothoracic Surgery Saiseikai Suita Hospital
-
Yamada Tsutomu
Department Of Cardiovascular Surgery Nihon University School Of Medicine
-
Shirakashi Jun-ichi
Department of Electrical and Electronic Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan
-
Shirakashi Jun-ichi
Department of Electrical and Electronic System Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
-
Takemura Yasushi
Department of Electrical and Computer Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya, Yokohama 240-8501, Japan
関連論文
- Papillary Fibroelastoma of the Aortic Valve : Evaluation with Transesophageal Echocardiography and Magnetic Resonance Imaging
- Strategies for a Schizophrenic Patient Who Required Aortic Valve Replacement
- A Novel Technique for Removal of Permanent Pacemaker Leads
- Impact of Myocardial Angiotensin-Converting Enzyme Activity on Coronary Vascular Resistance and Serum Brain Natriuretic Peptide Concentration in Coronary Bypass Surgery
- Elevation of Brain Natriutetic Peptide in Pericardia! Fluid in Patients with Postoperative Atrial Fibrillation Undergoing Off-Pump Coronary Artery Bypass Surgery
- Ubiquitin-Positive Pneumocytes and Inclusion Bodies are Present in Secondary Organizing Pneumonia
- Effects of Lentinus edodes mycelia on Dietary-Induced Atherosclerotic Involvement in Rabbit Aorta
- Ubiquitin-Positive Foam Cells are Identified in the Aortic and Mitral Valves with Atherosclerotic Involvement
- Magnetization Switching of Magnetic Submicron Structure Fabricated by Atomic Force Microscope
- AFM Nano-oxidation of NiFe Thin Films Capped with Al-Oxide Layers for Planar-type Tunnel Junction
- InGaP/GaAs Heterojunction Bipolar Transistors with an Ultra-High Carbon-Doped Base (p=1.5×10^cm^)
- Low Temperature Growth of Heavily Carbon-Doped GaAs by Metalorganic Molecular Beam Epitaxy with Elemental Gallium
- P-Type Carbon-Doped InGaAs Grown by Metalorganic Molecular Beam Epitaxy
- Protective Effect of N-methyl-l-deoxynojirimycin on Lung Ischemia Reperfusion Injury : An in vivo Study : MdNM Reduces Lung Ischemia Reperfusion Injury
- Left and Right Coronary Circulation in Left Ventricular Hypertrophy : Effects of Angiotensin Converting Enzyme Inhibition
- Pathological Findings of Tissue Reactivity of Gelatin Resorcin Formalin Glue : An Autopsy Case Report of the Repair of Ventricular Septal Perforation
- Large Spike in Myeloma Serum due to Retention of Dimeric Bence Jones Kappa Proteins
- Subpectoral Technique of Pacemaker Implantation : Reduction of Cost and Length of Hospital Stay
- INHIBITORY EFFECTS OF ARGATRORAN ON THROMBIN ACTIVATION AFTER PERCUTANEOUS CORONARY ANGIOPLASTY
- Biomechanical study of the development of scoliosis, using a thoracolumbar spine model
- Scratch Nanolithography on Si Surface Using Scanning Probe Microscopy: Influence of Scanning Parameters on Groove Size
- A Case of Antithrombin III Deficiency Diagnosed and Treated During Mitral Valve Replacement
- Open Heart Surgery in a Paraplegic Patient
- A Comparative Study of Cultured Smooth Muscle Cell Proliferation and Injury, Utilizing Glycated Low Density Lipoproteins with Slight Oxidation, Auto-oxidation, or Extensive Oxidation
- Self-Limitting Growth in Atomic Layer Epitaxy of ZnTe
- Entire Removal of Screw-In Pacing Leads 3 Years after Implantation
- Measurement of Reaction Current during Atomic Force Microscope Local Oxidation of Conductive Surfaces Capped with Insulating Layers
- Sub-20 nm Scratch Nanolithography for Si Using Scanning Probe Microscopy
- Semi-Nested Real-Time Reverse Transcription Polymerase Chain Reaction Methods for the Successful Quantitation of Cytokeratin mRNA Expression Levels for the Subtyping of Non-Small-Cell Lung Carcinoma Using Paraffin-Embedded and Microdissected Lung Biopsy S
- Micrometer-Scale Local-Oxidation Lithography Using Scanning Probe Microscopy
- Local Oxidation of Si Surfaces by Tapping-Mode Scanning Probe Microscopy: Size Dependence of Oxide Wires on Dynamic Properties of Cantilever
- Control of Tunnel Resistance of Nanogaps by Field-Emission-Induced Electromigration