Similarities and differences of the thermal analysis issues between the intelligent and general AC contactors are analyzed. Heat source model of the magnet system is established according to the unique control mode of the intelligent AC contactor. Linking with the features common of the two kinds of contactors, the extension of the thermal analysis method of the general AC contactor to the intelligent AC contactor is demonstrated. Consequently, a comprehensive thermal analysis model considering heat sources of both main circuit and magnet system is constructed for the intelligent AC contactor. With this model, the steady-state temperature rise of the intelligent AC contactor is calculated and compared with the measurements of an actual intelligent AC contactor.
著者
-
JI Liang
State Key Laboratory of Electric Insulation and Power Equipment, Xian Jiaotong University
-
CHEN Degui
State Key Laboratory of Electric Insulation and Power Equipment, Xian Jiaotong University
-
LIU Yingyi
School of Electrical Engineering, Beihang University
-
LI Xingwen
State Key Laboratory of Electric Insulation and Power Equipment, Xian Jiaotong University
関連論文
- Thermal Simulation of a Contactor with Feedback Controlled Magnet System
- Investigation on the Interruption Process of Molded Case Circuit Breakers Including the Influence of Blow Open Force (国際セッションIS-EMD2005) -- (Contactors & Circuit Breakers)
- Calculation and Analysis of Dynamic Characteristics of Multilink Permanent Magnetic Actuator in Vacuum Circuit Breaker
- Analysis of the Dynamic Characteristics of the Permanent Magnetic Actuator with Multi-bar Linkage
- A Fuzzy Logic-Wavelet Transform Based Energy Management Strategy for Battery/Ultra-capacitor Composite Power Supply for Robots
- Development of Fault Modeling Platform and Inference System for Electrical Control System
- Study on Zero-Flux Application for Restraining the Remanence of High-DC-power Electromagnet
- Investigation on Dynamic Performance of Active Filter for Isolated Power System
- An Integrated Calculation Method to Predict Arc Behavior
- Analysis and Research on Electro-Dynamic Repulsion Force Acting on the Paralleled Conductors in Air Circuit Breaker(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from ICEC2006))
- Preliminary Study of the Magnetic Method Used to Measure Air Arc Behavior
- A New Method to Evaluate the Short-Time Withstand Current for Air Circuit Breaker
- Analysis and Optimization for a Contactor with Feedback Controlled Magnet System
- Effect of Back-Volume of Arc-Quenching Chamber on Arc Behavior
- Analysis and Optimization for AC Contactor with Feedback Controlled Magnet System(Session 8 -Contactors & Breakers-)
- Thermal Analysis of AC Contactor Using Thermal Network Finite Difference Analysis Method(Session 7 -Modeling-)
- Dynamic Characteristic Analysis and Optimization for the Energy-Saving and Bounce-Reducing Double-Coil Contactor(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Dynamic Characteristic Analysis and Optimization for The Energy-Saving Contactor With Double Coils (国際セッションIS-EMD2005) -- (Contactors & Circuit Breakers)
- Investigation on the Dynamic Characteristics of a Magnetic Release in Molded Case Circuit Breaker(Contactors & Circuit Breakers, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Influence of the Linkage Transfer Position on the Interruption Performance of MCCB
- Simulation of Pressure Rise in Arc Quenching Chamber of Molded Case Circuit Breaker During its Interruption Process
- Simulation and Analysis for a Permanent Contactor with and without Current-Feedback System
- Simulation of the Interruption Process of MCCB with Double Repulsive Contacts
- Simulation and Analysis for a Permanent Contactor with and without Current-feedback System
- Analysis and Optimization for the Operating Mechanism of Air Circuit Breaker
- Analysis and Optimization for the Operating Mechanism of Air Circuit Breaker(Session 8 -Contactors & Breakers-)
- Thermal Analysis of AC Contactor Using Thermal Network Finite Difference Analysis Method
- Effect of Different Vent Configurations on the Interruption Performance of Arc Chamber
- Study of the Main Factors Affecting the Potential Distribution for Porcelain Zinc Oxide Arresters
- New Method to Model the Equivalent Circuit of the Pulse Generator in Electrical Fast Transient/Burst Test
- New Method to Model the Equivalent Circuit of the Pulse Generator in EFT/B Test
- The Influence of the Insulation Baffle of Iron Splitter Plates on Arc Behavior(Session 8 -Contactors & Breakers-)
- Experimental Investigation on the Arc Motion with Different Configurations of Quenching Chamber in AC Contactor(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Simulation of SF6 arc characteristic concerning different pressure boundary condition(Session 7 -Modeling-)
- Study of the Effect of Gassing Material on Arc Behavior in Low Voltage Circuit Breaker(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from ICEC2006))
- Investigation on the Interruption Process of Molded Case Circuit Breakers Including the Influence of Blow Open Force(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Experimental Investigation on the Arc Motion with Different Configurations of Arc Chamber in AC Contactor (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Measurement of the Dielectric Recovery Strength and Reignition of AC Contactors(Contactors & Circuit Breakers, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Thermal Simulation of a Contactor with Feedback Controlled Magnet System
- Calculation and Analysis of Dynamic Characteristics of Multilink Permanent Magnetic Actuator in Vacuum Circuit Breaker