Calculation and Analysis of Dynamic Characteristics of Multilink Permanent Magnetic Actuator in Vacuum Circuit Breaker
スポンサーリンク
概要
- 論文の詳細を見る
The dynamic characteristics are the key issues in the optimum design of a permanent magnetic actuator (PMA). A new approach to forecast the dynamic characteristics of the multilink PMA is proposed. By carrying out further developments of ADAMS and ANSOFT, a mathematic calculation model describing the coupling of mechanical movement, electric circuit and magnetic field considering eddy current effect, is constructed. With this model, the dynamic characteristics of the multilink PMA are calculated and compared with the experimental results. Factors that affect the opening time of the multilink PMA are analyzed with the model as well. The method is capable of providing a reference for the design of the PMA.
- (社)電子情報通信学会の論文
- 2010-09-01
著者
-
CHEN Degui
State Key Laboratory of Electric Insulation and Power Equipment, Xian Jiaotong University
-
LIU Yingyi
School of Electrical Engineering, Beihang University
-
YUAN Haiwen
School of Automation Science and Electrical Engineering, Beihang University
-
ZHANG Qingjie
School of Automation Science and Electrical Engineering, Beihang University
-
YUAN Haibin
School of Automation Science and Electrical Engineering, Beihang University
-
Liu Yingyi
Xi'an Jiaotong Univ. Chn
-
Liu Yingyi
School Of Automation Science And Electrical Engineering Beihang University
-
Yuan Haiwen
School Of Automation Science And Electrical Engineering Beihang University
-
Chen Degui
State Key Laboratory Of Electric Insulation And Power Equipment Xi'an Jiaotong University
-
Yuan Haibin
School Of Automation Science And Electrical Engineering Beihang University
-
Zhang Qingjie
School Of Automation Science And Electrical Engineering Beihang University
関連論文
- Thermal Simulation of a Contactor with Feedback Controlled Magnet System
- Investigation on the Interruption Process of Molded Case Circuit Breakers Including the Influence of Blow Open Force (国際セッションIS-EMD2005) -- (Contactors & Circuit Breakers)
- Calculation and Analysis of Dynamic Characteristics of Multilink Permanent Magnetic Actuator in Vacuum Circuit Breaker
- Analysis of the Dynamic Characteristics of the Permanent Magnetic Actuator with Multi-bar Linkage
- A fuzzy logic-wavelet transform based energy management strategy for battery/ultra-capacitor composite power supply for robots (Electromechanical devices)
- A Fuzzy Logic-Wavelet Transform Based Energy Management Strategy for Battery/Ultra-capacitor Composite Power Supply for Robots
- Development of Fault Modeling Platform and Inference System for Electrical Control System
- Development of fault modeling platform and inference system for electrical control system (Electromechanical devices)
- Study on Zero-Flux Application for Restraining the Remanence of High-DC-power Electromagnet
- Investigation on Dynamic Performance of Active Filter for Isolated Power System
- An Integrated Calculation Method to Predict Arc Behavior
- Analysis and Research on Electro-Dynamic Repulsion Force Acting on the Paralleled Conductors in Air Circuit Breaker(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from ICEC2006))
- Preliminary Study of the Magnetic Method Used to Measure Air Arc Behavior
- A New Method to Evaluate the Short-Time Withstand Current for Air Circuit Breaker
- Analysis and Optimization for a Contactor with Feedback Controlled Magnet System
- Effect of Back-Volume of Arc-Quenching Chamber on Arc Behavior
- Analysis and Optimization for AC Contactor with Feedback Controlled Magnet System(Session 8 -Contactors & Breakers-)
- Thermal Analysis of AC Contactor Using Thermal Network Finite Difference Analysis Method(Session 7 -Modeling-)
- Dynamic Characteristic Analysis and Optimization for the Energy-Saving and Bounce-Reducing Double-Coil Contactor(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Dynamic Characteristic Analysis and Optimization for The Energy-Saving Contactor With Double Coils (国際セッションIS-EMD2005) -- (Contactors & Circuit Breakers)
- Investigation on the Dynamic Characteristics of a Magnetic Release in Molded Case Circuit Breaker(Contactors & Circuit Breakers, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Influence of the Linkage Transfer Position on the Interruption Performance of MCCB
- Simulation of Pressure Rise in Arc Quenching Chamber of Molded Case Circuit Breaker During its Interruption Process
- Simulation and Analysis for a Permanent Contactor with and without Current-Feedback System
- Simulation of the Interruption Process of MCCB with Double Repulsive Contacts
- Simulation and Analysis for a Permanent Contactor with and without Current-feedback System
- Analysis and Optimization for the Operating Mechanism of Air Circuit Breaker
- Analysis and Optimization for the Operating Mechanism of Air Circuit Breaker(Session 8 -Contactors & Breakers-)
- Thermal Analysis of AC Contactor Using Thermal Network Finite Difference Analysis Method
- Effect of Different Vent Configurations on the Interruption Performance of Arc Chamber
- New Method to Model the Equivalent Circuit of the Pulse Generator in Electrical Fast Transient/Burst Test
- New Method to Model the Equivalent Circuit of the Pulse Generator in EFT/B Test
- The Influence of the Insulation Baffle of Iron Splitter Plates on Arc Behavior(Session 8 -Contactors & Breakers-)
- Experimental Investigation on the Arc Motion with Different Configurations of Quenching Chamber in AC Contactor(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Study of the Effect of Gassing Material on Arc Behavior in Low Voltage Circuit Breaker(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from ICEC2006))
- Investigation on the Interruption Process of Molded Case Circuit Breakers Including the Influence of Blow Open Force(Contactors & Circuit Breakers,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Experimental Investigation on the Arc Motion with Different Configurations of Arc Chamber in AC Contactor (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Measurement of the Dielectric Recovery Strength and Reignition of AC Contactors(Contactors & Circuit Breakers, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Thermal Simulation of a Contactor with Feedback Controlled Magnet System
- Calculation and Analysis of Dynamic Characteristics of Multilink Permanent Magnetic Actuator in Vacuum Circuit Breaker
- Effect of Different Vent Configurations on the Interruption Performance of Arc Chamber
- Investigation on Dynamic Performance of Active Filter for Isolated Power System
- The Static and Dynamic Analyses of actuator with Branch Magnetic circuit for Electronic trip of Low-Voltage Circuit Breaker
- Analysis of the Characteristics of an AC Solenoid Magnetic Release with Permanent Magnet
- The Influence of Back Gas Flow on the Interruption Performance of Low-Voltage Circuit Breaker
- Study of the Optimization Design of Low Voltage Circuit Breakers : A Systematic Review
- Study of the Interruption Process of the Selective Miniature Circuit Breaker