Formation Mechanism of Dark Bridge between Contacts with Very Slow Opening Speed(Contact Phenomena,<Special Section>Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
スポンサーリンク
概要
- 論文の詳細を見る
The mechanism of dark bridge formed with very slow contact separating speed was empirically shown with some discussions from the experimental results which the authors have obtained by using the cantilever system for controlling contact gap. By analyzing the obtained results, we will assume some concept of formation mechanism of dark bridge. Since the thermal effect is inevitable in the bridge formation, this will be inferred from two points; one is the a-spot change at initial state of bridge forming, and another one is the thermal expansion due to bridge current that affects the shape of bridge. This paper will show from these two points the conceptual bridge formation mechanism in case of non-melting state of contact bridge which is called here dark bridge.
- 社団法人電子情報通信学会の論文
- 2006-08-01
著者
-
Ishida H
Tohoku Bunka Gakuen Univ. Sendai Jpn
-
Suzuki Shosuke
Tohoku Bunka Gakuen University
-
Inoue Hiroshi
Akita University
-
Sone Hideaki
Tohoku University
-
ISHIDA Hiroyuki
Tohoku Bunka Gakuen University
-
TANIGUCHI Masanari
Tohoku Bunka Gakuen University
-
TAKAGI Tasuku
Tohoku Bunka Gakuen University
-
Sone Hideaki
Cyberscience Center Tohoku University
-
Takagi Tasuku
Tohoku University
-
Inoue Hiroshi
Akita Univ. Jpn
-
Inoue Hiroshi
Akita Univ. Akita Jpn
-
Inoue Hiroshi
Akita Univ.
関連論文
- A novel measurement method of electric field by using spherical dielectric scatterer (特集 2009年環境電磁工学国際シンポジウム)
- A Study on Generation and Break of Bridge at Different Material Contact Pairs
- B-4-48 A Study on EM Radiation from Stripline Structure with a Thin Wire
- Pulse Response Characteristic of Connector Contact Failure on a Coaxial Cable
- An Analysis of EM Radiation from Transmission Line with Loose Contact of Connector
- Effect of Contact Point Distribution to the High-Frequency Impedance on a Coaxial Connector
- Computation of Electromagnetic Field Distribution in a Cross-Section of Connector with Contact Failure
- Formation Mechanism of Dark Bridge between Contacts with Very Slow Opening Speed(Contact Phenomena,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Formation Mechanism of Dark Bridge between Contacts with Very Slow Opening Speed (国際セッション IS-EMD2005) -- (Contact Phenomena)
- Relationship between Length and Diameter of Contact Bridge Formed under Thermal Equilibrium Condition(Contact Phenomena, IS-EMD2004-Recent Development of Electro-Mechanical Devices)