Simplex Optimization of Reaction Conditions with an Automated System
スポンサーリンク
概要
- 論文の詳細を見る
An automated system for the optimization of experimental conditions was applied to the reaction of carboxylic acid. This system consists of a laboratory robotic system, a spectrophotometer, and a personal computer which are interfaced with each other. The optimum conditions were obtained according to the super modified simplex algorithm. This model reaction involved 3 or 4 parameters, and was optimized after 28 experiments at most. The effects of the initial simplex as well as the feasibility and efficiency of the system are discussed.
- 社団法人日本薬学会の論文
- 1988-09-25
著者
-
松田 りえ子
国立衛生試験所
-
武田 寧
National Institute of Hygienic Sciences
-
松田 りえ子
Division of Drugs, National Institute of Hygienic Sciences
-
石橋 無味雄
Division of Drugs, National Institute of Hygienic Sciences
-
武田 寧
Division of Drugs, National Institute of Hygienic Sciences
-
石橋 無味雄
国立衛生試験所
-
武田 寧
衛試
関連論文
- Application of Synthetic Hydrated Aluminum Silicates as Orally Administered Absorbents of Ammonium Ion
- Statistical Evaluation of Accelerated Stability Data Obtained at a Single Temperature. II. : Estimation of Shelf-Life from Remaining Drug Content
- Statistical Evaluation of Accelerated Stability Data Obtained at a Single Temperature. I. : Effect of Experimental Errors in Evaluation of Stability Data Obtained
- Epimerization and Racemization of Some Chiral Drugs in the Presence of Human Serum Albumin
- Relase Rates on Indomethacin from Commercial Witepsol Suppositories and the Bioavailabilities in Rabbits and Pigs
- CHARACTERIZATION OF CONTAMINANTS IN EMS-ASSOCIATED L-TRYPTOPHAN SAMPLES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
- Protein Denaturation in Dosage Forms Measured by Differential Scanning Calorimetry
- デプレニールとメタンフェタミンの尿中代謝物の比較に関する研究(第1報)サル尿中代謝物について
- Enzyme Linked Immunosorbent Assay (ELISA) Using Monoclonal Antibody to Detect Methamphetamine in Urine and Hair
- Epimerization and Racemization of Some Chiral Drugs in the Presence of Cyclodextrin and Liposomes
- FORMULATION-ASSISTED BIODEGRADABLE POLYMER MATRICES
- Epimerization and Hydrolysis of Etoposide Analogues in Aqueous Solution
- Application of Gel Permeation chromatograph-Low Angle Laser Light Scattering System to Kinetic Study on Degradation of Bioerodible Polymers
- ラボラトリーロボットによるアジマリン錠含量均一性試験の自動化の試み(品質管理・工程管理のための分析化学)
- Simplex Optimization of Reaction Conditions with an Automated System
- カルボキシル基を持つ医薬品のジシクロヘキシルカルボジイミドによる吸光光度定量(医薬品の分析)
- Formation of a Direct Mutagen, Diazo-N-nitrosoetilefrin, by Interaction of Etilefrin with Nitrite
- A Screening Procedure for the Formation of Nitroso Derivatives and Mutagens by Drug-Nitrite Interaction
- ラボラトリーロボットシステムを用いたSimplex法による反応条件の最適化
- Synthetic Hydrated Aluminum Silicates as Oral Adsorbents of Potassium Ion
- 高速液体クロマトグラフ法による体液中のテオフィリンの定量
- 高速液体クロマトグラフ法による混合製剤の分析(第6報)解熱鎮痛剤配合製剤の高速液体クロマトグラフィーによる定量
- 高速液体クロマトグラフ法による混合製剤の分析(第5報)総合感冒剤中の解熱鎮痛剤および抗ヒスタミン剤の高速液体クロマトグラフィーによる定量
- 英国農水産食糧省の「残留農薬分析のための品質管理-第2版」の紹介
- 1 酸と塩基 : Bronsted 説を中心に(化学反応 : その本質にせまる)
- とうもろこしの保存及びコーンスターチ製造による収穫後使用農薬の減衰
- 医薬品分析におけるエキスパートシステム
- 電量滴定による医薬品の分析(第3報)スルファメチゾール, スルファメトキシピリダジンおよびスルファフェナゾールの臭素化反応
- 電量滴定による医薬品の分析(第2報) : スルファメトキシピラジンの電量滴定
- 電量滴定による医薬品の分析(第1報) : スルホンアミド類の電量滴定
- 非水溶媒滴定によるバルビツール酸類および市販製品の定量法
- 分析に用いる溶媒の選択について : 日本薬局方での考え方
- 医薬品に残留する有機溶媒のクラス分け及び限度値について
- カシューナッツ中の2-アルキルシクロブタノン類の同定