ネオクプロイン-銅(I)錯陽イオンを用いたレニウムの溶媒抽出吸光光度定量法と間接原子吸光定量法
スポンサーリンク
概要
- 論文の詳細を見る
Perrhenate anion forms ion-pair compound with neocuproin copper(I) chelate cation and is extracted into ethyl acetate. The extractcd species shows orange color and an absorption maximum exists at 456 nm. The measurement of the species in the organic phase by spectrophotometric method as well as the measurement of extracted copper by atomic absorption spectrophotometric method allow determination of microamount of rhenium. The recommended procedures are as follows: To the sample solution (pH 3 to 5), add 3ml of 0.11% cupric sulfate solution, 5ml of 3.4% potassium dihydrogen phosphate solution and 2ml of 5% hydroxylamine sulfate solution. Adjust the volume to about 25ml with water, shake the solution for 3min with 10ml of ethyl acetate containing 0.042% of neocuproin. Separate the organic phase and dehydrate it with sodium sulfate anhydride. Determine rheuium concentration by either spectrophotometry or indirect atomic absorption spectrophotometry. The molar extinction coefficient of the species in ethyl acetate is 7.3×10^3. Both methods are applicable to determination of more than 5μg of rhenium. More than 1mg of molybdenum interfere with the determination.
- 社団法人日本分析化学会の論文
- 1977-04-05
著者
関連論文
- 炎光分析法による希土混合物中のイットリウムの定量
- 逆浸透膜裏打ち材による圧力損失について
- メチルバイオレットによるレニウムの抽出吸光光度定量法
- 炎光分析法による酸化イットリウム中の希土類元素の定量
- ネオクプロイン-銅(I)錯陽イオンを用いたレニウムの溶媒抽出吸光光度定量法と間接原子吸光定量法
- 溶液法けい光X線分析による希土類元素の定量
- 溶液法ケイ光X線分析によるイットリウムの迅速定量法
- 逆相クロマトグラフィー-紫外吸光光度法によるレニウムの定量
- リン酸トリブチル逆相クロマトグラフィーによるレニウムとモリブデンの分離
- レニウム・タングステン合金中のレニウムの定量
- チオ尿素によるレニウムの吸光光度定量法
- トリフェニルメタン色素によるレニウムの抽出吸光光度定量法
- 鉄鋼および鋳鉄中の亜鉛の定量