Measurement of Cyclic Stresses in High Temperature Range Using Nickel Electroplating : 3rd Report, Application of a Sulfamate Bath
スポンサーリンク
概要
- 論文の詳細を見る
Using an electroplated nickel, a fundamental research for measurement of cyclic stresses in high temperature range is carried out. The plating used consists of two layers, namely, a preliminary deposit of alkaline copper in a copper cyanide bath and a nickel deposit in a sulfamate bath. The plating conditions suitable for the present purpose are proposed. In the high temperature range from 125℃ to 200℃, crystal grains of deposited nickel are developed by cyclic stresses above a certain magnitude. Consequently, micro-flecks occur on the surface of deposits depending on the magnitude of applied cyclic stresses. The stress concentration factors in grooved shafts under bending are obtained at 160℃ and 180℃. The results are compared with the theoretical and experimental results obtained previously.
- 一般社団法人日本機械学会の論文
著者
-
Ota Hitoshi
Nippon Steel Corporation
-
SEIKA Masaichiro
Faculty of Engineering,Nagoya University
-
HOSONO Kikuo
Faculty of Engineering,Nagoya University
-
Hosono Kikuo
Faculty Of Engineering Nagoya University
-
Seika Masaichiro
Faculty Of Engineering Nagoya University
関連論文
- Basic Research on Slip-initiation Phenomenon by Fatigue and Its Application to Stress Measurement
- Measurement of Cyclic Stresses in High Temperature Range Using Nickel Electroplating : 3rd Report, Application of a Sulfamate Bath
- On the Temperature- and cyclic speed-dependence of the Method of Stress Measurement Using Iron-foils
- Stress Measurement Using Slip-initiation Phenomenon in Iron Foil
- Basic Study on Stress Measurement Using Slip-initiation Phenomenon in Electro-deposited Iron
- Measurement of Cyclis Stresses Caused in High Temperature Range by Nickel Electroplating : 4th Report, An Application of Copper Sulfate Bath for the Basal Plating
- Basic Study on Foil Strain Gauges Made of Electrodeposited Copper or Nickel
- Fundamental Studies on the Copper and Nickel Electroplating Methods of Stress Analysis : Effects of the Ground Plating on the Proper Stress
- Dependence of the Threshold Stress of Microcrack Propagation on the Stress Ratio
- The Effect of Crack Closure on the Threshold of Micro Fatigue Crack Propagation under Mixed Mode
- Photoelastic Study of Stresses in a Cylindrical Pressure Vessel with a Nozzle : 1st Report, Flush Type Nozzle
- Examination of Fatigue Failure of Metals by Means of Electro-Plating Method
- Measurement of Stress Concentrations in Threaded Connections
- Measurement of Cyclic Stresses in High Temperature Range Using Nickel Electroplating : 2nd Report, Examination of Applicable Temperature and Accuracy of Measured Values
- Measurement of Cyclic Stresses in High Temperature Range Using Nickel Electroplating : 1st Report, Plating Conditions and Calibration Tests
- Fundamental Study on a Foil Strain Gauge of Electrodeposited Nickel
- On the Understressing Effect of the Eutectoid Steel
- A Study on the Improvement in Sensitivity of Strain Gauges Made of Copper Electrodeposited Foil
- The Threshold of Micro Crack Propagation under Mixed Mode
- The Behavior of Fatigue Cracks in Pure Iron Subjected to Rotary Bending and Cyclic Torsion : 2nd Report, Effect of Crystal Grain Size
- The Behavior of Fatigue Cracks in Pure Iron Subjected to Rotary Bending and Cyclic Torsion : 1st Report, Stress-Concentration Factor and Fatigue-Notch Factor due to Fatigue Cracks
- On the Understressing Effect of the Eutectoid Steel at -60℃
- Change of Material Properties at the Tips of Fatigue Cracks Subjected to Macroscopic Tensile and Shear Stresses for Propagation : in Rotary Bending and Cyclic Torsion
- Photoelastic Investigation of the Maximum Stress in a Plate with a Reinforced Circular Hole under Tension
- Examination of the Adaptability of the Copper Electroplating Method of Stress Analysis to the Low Temperature Range