Measurement and analysis of neutron spectrum in a molybdenum pile.
スポンサーリンク
概要
- 論文の詳細を見る
In order to assess the neutron cross section for Mo, the angular neutron spectrum at r=15 cm and μ=0 in a spherical Mo pile of 60 cm I.D. was measured by the linac timeofflight method. The result was compared with the theoretical calculations which were predicted by making use of group constants produced from JENDL-1 (MAT=1420) and ENDF/B-IV (MAT=1287).<BR>The predicted spectrum from the ENDF/B-IV data gives higher flux by about 30% than the measured one in the energy region above 500 keV, while the spectrum calculated from the JENDL-1 data is in better agreement with the measured one.<BR>Substitution of four kinds of partial cross sections from JENDL-1 into ENDF/B-IV was tried and the results were compared with each other. These calculations show that the discrepancy between the measured spectrum and the predicted one from the ENDF/B-IV data is mainly due to the fact that the ENDF/B-IV data has no discrete levels of inelastic scattering of neutrons for Mo.
- 一般社団法人 日本原子力学会の論文
著者
-
Mori Takamasa
Department Of Molecular Design And Engineering Graduate School Of Engineering Nagoya University
-
Yamamoto Shuji
Research Center For Cancer Prevention And Screening National Cancer Center
-
Kobayashi Katsuhei
Research Reactor Institute Kyoto Uninversity
-
Kimura Itsuro
Research Reactor Institute Kyoto University
-
Nakagawa Masayuki
Japan Atomic Energy Research Institute
-
Nishihara Hiroshi
Department Of Chemistry Faculty Of Science And Technology Keio University
-
HAYASHI Shu
Research Reactor Institute, Kyoto University
関連論文
- 209 CT Colonographyにおける専用寝台マットの考案 : 撮影体位の違いによる大腸拡張度の検討(CT検査 Colonography,第36回日本放射線技術学会秋季学術大会)
- 210 CT Colonographyにおける専用寝台マットの考案 : 補助具使用による腸管拡張改善度の検討(CT検査 Colonography,第36回日本放射線技術学会秋季学術大会)
- Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact : evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis
- Accurate Thickness Measurement of Two Adjacent Sheet Structures in CT Images(Advanced Image Technology)
- 375 内臓脂肪症候群に着目した在宅医療支援システムの構築(医療情報管理医療連携, 第35回日本放射線技術学会秋季学術大会プログラム)
- A novel automatic liver surface registration method using spherical harmonics (パターン認識・メディア理解)
- A novel automatic liver surface registration method using spherical harmonics (画像工学)
- A novel automatic liver surface registration method using spherical harmonics (医用画像)
- 34 肺がんにおける3次元CT画像処理ソフトウェアの開発(CT検査 応用技術,第36回日本放射線技術学会秋季学術大会)
- 放射線治療における CR Portal Image のCLAHE処理の検討
- 261 情報ハイディング技術を用いた医用画像に対する安全で廉価なセキュリティモデルの構築(医療情報管理教育・評価分析・他, 第35回日本放射線技術学会秋季学術大会プログラム)
- 233 マンモグラフィ精度管理支援ソフトウェアの開発とその評価(画像工学 マンモグラフィー画像処理,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- Computational Flow Dynamics in Abdominal Aortic Aneurysm Using Multislice Computed Tomography
- サイバー空間を利用した未来の保健・福祉・医療(新春座談会)
- Evaluation of Coronary Artery Bypass Grafts Using Multidetector-row CT with Japanese Patients
- Multiscale vessel tracking and quantification from isotropic CT volume data(Joint Session 2)
- Voxel Dimensions Required for Micromorphologic Evaluation of Ground-glass Opacity on Lung High-resolution CT
- PACS for Multi-slice CT : Seamless Integration Implementing 3D and 4D Workstations
- Evaluation of Major Aortopulmonary Collateral Arteries (MAPCAs) Using Three-dimensional CT Angiography : Two Case Reports
- Real-time Estimation System for Mean Glandular Dose in Mammography
- Coronal Multiplanar Reconstruction View from Whole Lune Thin-section CT by Multidetector-row CT : Determination of Malignant or Benign Lesions and Differential Diagnosis in 68 Cases of Solitary Pulmonary Nodule
- Coronal Multiplanar Reconstruction View from Isotropic Voxel Data Sets Obtained with Multidetector-row CT : Assessment of Detection and Size of Mediastinal and Hilar Lymph Nodes
- Technical Application of Three-dimensional Visualization and Measurement for Breast Cancer Using Multidetector-row CT Scanner
- Evaluation of Compressed Lung CT Image Quality Using Quantitative Analysis
- Evaluation of Image Quality and Spatial Resolution of Low-dose High-pitch Multidetector-row Helical High-resolution CT in 11 Autopsy Lungs and a Wire Phantom
- Pitfalls in the Interpretation of Multidetector-row Helical CT Images at Window Width and Level Setting for Lung Parenchyma
- A case of nonspecific interstitial pneumonia (NSIP), which was indistinguishable from desquamative interstital pneumonia (DIP) on high-resolution CT
- Development of an Automated 3D Segmentation Program for Volume Quantification of Body Fat Distribution Using CT
- Periodic analysis of urethane-induced pulmonary tumors in living A/J mice by respiration-gated X-ray microcomputed tomography
- Optimized Control of X-ray Exposure and Image Noise Using a Particular Multislice CT Scanner
- DICOMによる超音波画像解析用ビューワの開発
- CTの自動被ばく線量表示を搭載したPET-CT画像解析ソフトウェアの開発 : CT-AEC(Auto Exposure Control)に対応した実効線量計算ソフトの実装(第63回総会学術大会放射線防護・管理関連後抄録)
- 10 CTコロノグラフィにおける炭酸ガス持続注入器の有用性(CT検査撮影技術2, 第35回日本放射線技術学会秋季学術大会プログラム)
- 動画保存におけるファイル形式の違いによる画質の物理的評価
- Technical Aspects of X-ray Micro-computed Tomography: Initial Experience of 27-μm Resolution Using Feldkamp Cone-beam Reconstruction
- 212 マルチスケール・マルチフィジックスによる医用画像処理の統合化(画像工学 画像計測,統合化,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- 211 PET-CTにおける3次元画像処理 : SUVを用いた代謝計測値マッピング法の考案(画像工学 画像計測,統合化,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- Segmentation of liver in low-contrast images using K-means clustering and a priori knowledge (パターン認識・メディア理解)
- Segmentation of liver in low-contrast images using K-means clustering and a priori knowledge (画像工学)
- Segmentation of liver in low-contrast images using K-means clustering and a priori knowledge (医用画像)
- A rule based technique for liver segmentation in CT data (医用画像)
- Automated Determination of the Liver Boundary in CT Data Based on Anatomical Knowledge and Level Set Method
- Automated segmentation of the hip bones and cartilages in multi-slice CT images (医用画像)
- Automated visualization of femoral and acetabular cartilages in MR images of the hip (医用画像)
- A Knowledge Based Technique for Automatic Segmentation of the Hip Femoral Cartilage in CT Images
- Automated Segmentation of Acetabular Cartilage in MR images of the Hip(Joint Session 1)
- Hypervascular hepatocellular carcinoma : Combined dynamic MDCT and SPIO-enhanced MRI versus combined CTHA and CTAP
- Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors
- Analysis of entrance surface dose in general radiographies using body mass index classification
- Measurement of Neutron Capture Cross Section of ^Np from 0.02 to 100eV
- Enhanced Diffusion and Lattice Location of Indium and Gallium Implanted in Silicon
- A Hybrid Technique for Thickness-Map Visualization of the Hip Cartilages in MRI
- Development of a novel slurry condensation method by applying dispersant instead of flocculant
- Model-based Measurement of the Articular Cartilage Thickness in the Hip Joint
- Measurements of Neutron-induced Fission Cross Section of Protactinium-231 from 0. 1eV to 10keV with Lead Slowing-down Spectrometer and at 0. 0253eV with Thermal Neutron Facility
- Measurements of Neutron-induced Fission Cross Section of Americium-243 from Thermal Neutron Energy to 15keV Using Lead Slowing-down Spectrometer and Thermal Neutron Facility
- Neutron Capture Cross Section Measurement of Praseodymium in the Energy Region from 0.003eV to 140keV
- Measurement of Neutron Capture Cross Section of ^Np by Linac Time-of-Flight Method and with Linac-driven Lead Slowing-down Spectrometer
- Application of BGO Scintillators to Absolute Measurement of Neutron Capture Cross Sections between 0. 01 eV and 10 eV
- Behavior of Excess Te Atoms in Undoped p-type CdTe Annealed under Te Vapor Pressures
- Anodic Oxidation of CdTe as a Thin-Layer Removal Technique
- Production of Pure ^Pu Tracer for the Assessment of Plutonium in the Environment
- Benchmark Analysis of Experiments in Fast Critical Assemblies Using a Continuous-Energy Monte Carlo Code MVP
- Validation of a Continuous-Energy Monte Carlo Burn-up Code MVP-BURN and Its Application to Analysis of Post Irradiation Experiment
- CT Colonographyにおける送気ガスの違いによる腸管拡張度に関する検討
- Ion-Implanted Arsenic Profiles in GaAs Encapsulated by SiO_2 and Si_3N_4
- Comparison between Concentration Profiles of Arsenic Implanted in Silicon Measured by Means of Neutron Activation Analysis and Radioactive Ion Implantation
- Concentration Profiles of Room Temperature Ion Implanted Indium in Silicon
- Enhanced Diffusion of Ion Implanted Sb in Silicon
- Halogen and Mercury Lamp Annealing of Arsenic Implanted into Silicon
- Radioactive Analysis of Palladium Used for an Explosive Cold Fusion Experiment
- Determination of Thermal and Intermediate Neutron Spectrum at UTR-KINKI Using Cd-Ratio Measurements by Activation Method
- Annealing Behavior of Arsenic and Gallium Implanted in Silicon with Thin Native-Oxide Films
- Effects of Neutron Resonance Interference between Ta and Au
- Effects of particle concentration and additive amount of dispersant on adsorption behavior of dispersant to alumina particles
- Solidification mechanism of the sediment formed by particle settling - Analysis of the formation of the solidified layer
- Solidification Mechanism of the Sediment Formed by Particle Settling - Analysis of the Final State of the Sediment
- A new slurry evaluation technique by using ultrasonic attenuation
- Slurry characterization by hydrostatic pressure measurement : analysis based on apparent weight flux ratio
- Flux Distribution in Phantom for Biomedical Use of Beam-Type Thermal Neutrons
- Neutron Capture Cross Section Measurement of Praseodymium in the Energy Region from 0.003eV to 140keV
- Measurement and analysis of neutron spectra in lithium fluoride and polytetrafluoroethylene piles.
- Cross section measurement for 199Hg(n,n')199mHg reaction from 0.78 to 6.3MeV.
- Measurement and analysis of fast neutron spectra in iron, nickel and chromium.
- Measurement of neutron capture cross sections with Fe-filtered beam.
- Precision Neutron Total Cross Section Measurements Near 24 keV
- Measurement of Cross Section for the 103Rh(n, n')103mRh Reaction and Its Application to Fast Neutron Flux Measurements
- Measurement of Fission Cross Section of Neptunium-237 in Resonance Region with Electron Linac-Driven Lead Spectrometer.
- Assessment of neutron cross sections for titanium with neutron spectrum in titanium pile.
- Neutron capture cross section measurements of Nb-93, I-127, Ho-165, Ta-181 and U-238 between 3.2 and 80keV.
- Experimental study about the agglomeration behavior in slurry prepared by adding excess polyelectrolyte dispersant
- Fission spectrum averaged cross sections of some threshold reactions measured with fast reactor "YAYOI".
- Measurement and analysis of neutron spectrum in spherical pile of thoria.
- Measurement and analysis of neutron spectrum in a molybdenum pile.
- Some relations of neutronic noise with fluctuation of inlet coolant temperature and vibration of a control rod obtained by simultaneous measurements at KUR.
- Neutron spectrum in small iron pile surrounded by lead reflector.
- Measurement and covariance analysis of californium-252 spectrum averaged cross sections.
- Measurement of neutron capture cross section of thorium-232 from 1 keV to 408 keV.
- Measurement of neutron total cross section of silicon at 146- and 53.5-keV windows.
- Preparation of Uranium-233 with Low Uranium-232 Content