Multiscale vessel tracking and quantification from isotropic CT volume data(Joint Session 2)
スポンサーリンク
概要
- 論文の詳細を見る
A unified multiscale filtering framework is provided for centerline detection, tracking, and diameter quantification of vessels in isotropic CT data. A method fully utilizes multiscale line filter responses for tracking vessels and estimating their diameters. The diameter estimation problem is formulated as a least square fitting of a sequence of multiscale responses obtained at each centerline point to the precomputed multiscale response curve for the ideal line model. Small-diameter structures are accurately quantitated by incorporating the estimation of the point spread function (PSF) of a CT scanner. The method was evaluated through simulations and phantom experiments and demonstrated to accurately measure small-diameter structures which are significantly overestimated by conventional methods. Experimental results using clinical CT data are also shown.
- 社団法人電子情報通信学会の論文
- 2005-09-15
著者
-
山本 修司
Research Center For Cancer Prevention And Screening National Cancer Center
-
山本 修司
国立がんセンター がん予防・検診研究センター
-
SATO Yoshinobu
Division of Image Analysis, Osaka University Graduate School of Medicine
-
TAMURA Shinichi
Division of Image Analysis, Osaka University Graduate School of Medicine
-
竹内 規之
大阪大学医学部放射線医学教室
-
中村 仁信
大阪医科大学 放射線医学教室
-
中村 仁信
りんくう総合医療センター市立泉佐野病院 放射線科
-
TOMIYAMA Noriyuki
Department of Radiology, Osaka University Graduate School of Medicine
-
NAKAMURA Hironobu
Department of Radiology, Osaka University Graduate School of Medicine
-
Yamamoto Shuji
Institute of Medical Science, University of Tokyo
-
Tomiyama Noriyuki
Department Of Radiology Graduate School Of Medicine Osaka University
-
Tomiyama Noriyuki
自治医科大学 内科学呼吸器内科学
-
Sato Yoshinobu
Division Of Image Analysis Graduate School Of Medicine Osaka University
-
Tamura S
Graduate School Of Medicine Osaka University
-
Hiraoka Nobuaki
Department Of Radiology Osaka University Graduate School Of Medicine
-
Yamamoto Shuji
Research Center For Cancer Prevention And Screening National Cancer Center
-
中村 仁信
大阪大学医学部放射線科
-
Nakamura Hironobu
自治医科大学 内科学呼吸器内科学
-
Naito Hiroaki
大阪大学 医学系研究科臨床画像解析学
-
Sato Y
Division Of Image Analysis Graduate School Of Medicine Osaka University
-
Nakamura Hironobu
Department Of Radiology
-
Yamamoto Shuji
大阪大学 医学系研究科保健学専攻
-
Sato Yoshinobu
Division Of Digestive And General Surgery Department Of Surgery Niigata University Graduate School O
-
Nagano Hiroaki
Department Of Surgery Graduate School Of Medicine Osaka University
-
Nose Takeyuki
Department Of Radiology Osaka University Medical School
-
Nakamura Hironobu
Department Of Radiology Osaka University School Of Medicine
-
Tamura S
Osaka Univ. Graduate School Of Medicine
-
Tomiyama Noriyuki
Department Of Radiology Ehime National Hospital
-
Takahashi Satoru
Department Of Clinical Informative Imageology Osaka University Graduate School Of Medicine
-
Tamura Shinichi
Division Of Image Analysis Osaka University Graduate School Of Medicine
-
Tamura Shinichi
Division Of Functional Diagnostic Imaging Biomedical Research Center Osaka University Medical School
-
Nakamura Hironobu
Department Of Radiology Osaka University Medical School.
-
Nakamura Hironobu
Department Of Materials Science Faculty Of Engineering Ibaraki University
-
Sato Yoshinobu
Division Of Image Analysis Department Of Medical Engineering Osaka University Graduate School Of Med
-
Nagano Hiroaki
Division Of Hepatobiliary And Pancreatic Medicine Department Of Internal Medicine Hyogo College Of Medicine
-
TOMIYAMA Noriyuki
Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine
関連論文
- 多階層統計的形状モデルにおける安定化項の有効性の検証(JAMITセッション)
- 209 CT Colonographyにおける専用寝台マットの考案 : 撮影体位の違いによる大腸拡張度の検討(CT検査 Colonography,第36回日本放射線技術学会秋季学術大会)
- 210 CT Colonographyにおける専用寝台マットの考案 : 補助具使用による腸管拡張改善度の検討(CT検査 Colonography,第36回日本放射線技術学会秋季学術大会)
- Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact : evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis
- Accurate Thickness Measurement of Two Adjacent Sheet Structures in CT Images(Advanced Image Technology)
- 375 内臓脂肪症候群に着目した在宅医療支援システムの構築(医療情報管理医療連携, 第35回日本放射線技術学会秋季学術大会プログラム)
- PS-126-6 Perfusion CT(Deconvolution法)による肝組織血流量測定の検討
- ISSVA分類に基づく頭頸部血管奇形の診療の実際
- CTによる心機能評価の進歩
- F-78 微小肺結節に対するパイロメトリー同期法を用いたCTガイド下肺生検の有用性の検討
- 大動脈炎症候群における time resolved multi-phase MR angiography の有用性
- 0831 Time resolved multi-phase 3D angiography:MRAかCTAか?
- BOOP,慢性好酸球性肺炎について
- 左室乳頭筋収縮能評価におけるへリカルCTの有用性
- P-217 Thin-section CTデータを用いた肺区域分割ソフトの開発,区域気管支による精度評価(縮小手術,第49回日本肺癌学会総会号)
- 181 胸部腫瘤性病変に対する超音波ガイド経皮針生検 : 124例の検討
- 成人日本人における胸部X線像上の縦隔線の検討
- 高速シネMR法を用いた冠動脈MRアンジオグラフィ -狭窄診断基準の検討-
- E-32 孤立性のbronchioloalveolar carcinomaのCT画像 : 細胞亜型からみた検討
- 非イオン性ヨード造影剤およびガドリニウム造影剤の重症副作用および死亡例の頻度調査
- HIS/RISの臨床評価のための測定方法とその一般化に関する研究
- P-381 肺腺癌の腫瘍径と予後に関するプロフィールカーブを用いた1次元定量解析(画像診断5,第49回日本肺癌学会総会号)
- A novel automatic liver surface registration method using spherical harmonics (パターン認識・メディア理解)
- A novel automatic liver surface registration method using spherical harmonics (画像工学)
- A novel automatic liver surface registration method using spherical harmonics (医用画像)
- 7.気管・気管支癌高線量率管腔内照射の適応と問題点 : 初期の経験から : 第57回日本肺癌学会関西支部会
- P-179 新しい高線量率小線源による気管・気管支癌症例に対する管腔内照射
- 34 肺がんにおける3次元CT画像処理ソフトウェアの開発(CT検査 応用技術,第36回日本放射線技術学会秋季学術大会)
- 放射線治療における CR Portal Image のCLAHE処理の検討
- 261 情報ハイディング技術を用いた医用画像に対する安全で廉価なセキュリティモデルの構築(医療情報管理教育・評価分析・他, 第35回日本放射線技術学会秋季学術大会プログラム)
- 第56回日本肺癌学会関西支部会 : 39.気管・気管支癌症例に対する新しい高線量率小線源治療
- 322 循環系数理モデルによる造影パラメータを考慮した流体力学シミュレーション(X線検査血管撮影(被ばく・アンギオCT), 第35回日本放射線技術学会秋季学術大会プログラム)
- 233 マンモグラフィ精度管理支援ソフトウェアの開発とその評価(画像工学 マンモグラフィー画像処理,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- Computational Flow Dynamics in Abdominal Aortic Aneurysm Using Multislice Computed Tomography
- サイバー空間を利用した未来の保健・福祉・医療(新春座談会)
- Evaluation of Coronary Artery Bypass Grafts Using Multidetector-row CT with Japanese Patients
- Multiscale vessel tracking and quantification from isotropic CT volume data(Joint Session 2)
- Voxel Dimensions Required for Micromorphologic Evaluation of Ground-glass Opacity on Lung High-resolution CT
- PACS for Multi-slice CT : Seamless Integration Implementing 3D and 4D Workstations
- Evaluation of Major Aortopulmonary Collateral Arteries (MAPCAs) Using Three-dimensional CT Angiography : Two Case Reports
- Real-time Estimation System for Mean Glandular Dose in Mammography
- Coronal Multiplanar Reconstruction View from Whole Lune Thin-section CT by Multidetector-row CT : Determination of Malignant or Benign Lesions and Differential Diagnosis in 68 Cases of Solitary Pulmonary Nodule
- Coronal Multiplanar Reconstruction View from Isotropic Voxel Data Sets Obtained with Multidetector-row CT : Assessment of Detection and Size of Mediastinal and Hilar Lymph Nodes
- Technical Application of Three-dimensional Visualization and Measurement for Breast Cancer Using Multidetector-row CT Scanner
- Evaluation of Compressed Lung CT Image Quality Using Quantitative Analysis
- Evaluation of Image Quality and Spatial Resolution of Low-dose High-pitch Multidetector-row Helical High-resolution CT in 11 Autopsy Lungs and a Wire Phantom
- Pitfalls in the Interpretation of Multidetector-row Helical CT Images at Window Width and Level Setting for Lung Parenchyma
- A case of nonspecific interstitial pneumonia (NSIP), which was indistinguishable from desquamative interstital pneumonia (DIP) on high-resolution CT
- Development of an Automated 3D Segmentation Program for Volume Quantification of Body Fat Distribution Using CT
- Periodic analysis of urethane-induced pulmonary tumors in living A/J mice by respiration-gated X-ray microcomputed tomography
- Optimized Control of X-ray Exposure and Image Noise Using a Particular Multislice CT Scanner
- DICOMによる超音波画像解析用ビューワの開発
- CTの自動被ばく線量表示を搭載したPET-CT画像解析ソフトウェアの開発 : CT-AEC(Auto Exposure Control)に対応した実効線量計算ソフトの実装(第63回総会学術大会放射線防護・管理関連後抄録)
- 10 CTコロノグラフィにおける炭酸ガス持続注入器の有用性(CT検査撮影技術2, 第35回日本放射線技術学会秋季学術大会プログラム)
- 動画保存におけるファイル形式の違いによる画質の物理的評価
- Technical Aspects of X-ray Micro-computed Tomography: Initial Experience of 27-μm Resolution Using Feldkamp Cone-beam Reconstruction
- 212 マルチスケール・マルチフィジックスによる医用画像処理の統合化(画像工学 画像計測,統合化,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- 211 PET-CTにおける3次元画像処理 : SUVを用いた代謝計測値マッピング法の考案(画像工学 画像計測,統合化,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- 6.気道3DヘリカルCTによる先天性気管狭窄症の画像診断法(第6回日本小児呼吸器外科研究会)
- A New Strategy for Lung Cancer Treatment : Impact of Real-Time Navigation on Thoracoscopic Surgery
- 27.肺癌のMRIによるT因子診断:肺血管浸潤、胸膜浸潤に関して : 第57回日本肺癌学会関西支部会
- Segmentation of liver in low-contrast images using K-means clustering and a priori knowledge (パターン認識・メディア理解)
- Segmentation of liver in low-contrast images using K-means clustering and a priori knowledge (画像工学)
- Segmentation of liver in low-contrast images using K-means clustering and a priori knowledge (医用画像)
- A rule based technique for liver segmentation in CT data (医用画像)
- Automated Determination of the Liver Boundary in CT Data Based on Anatomical Knowledge and Level Set Method
- Automated segmentation of the hip bones and cartilages in multi-slice CT images (医用画像)
- Automated visualization of femoral and acetabular cartilages in MR images of the hip (医用画像)
- A Knowledge Based Technique for Automatic Segmentation of the Hip Femoral Cartilage in CT Images
- Automated Segmentation of Acetabular Cartilage in MR images of the Hip(Joint Session 1)
- Evaluation of usefulness of color digital summation radiography for solitary pulmonary nodules on chest radiographs
- Evaluation of the usefulness of color digital summation radiography in temporally sequential digital radiographs : a phantom study
- Image Quality of High-resolution CT with 16-channel Multidetector-row CT : Comparison between Helical Scan and Conventional Step-shoot Scan
- Imaging of Fine Structure of Bone Sample with High Coherent X-ray Beam and High Spatial Resolution Detector
- Present status and perspectives of bioartificial kidneys
- Preoperative assessment of thymic veins on multidetector row CT : optimization of contrast material volume
- MR imaging of thymic epithelial tumors : correlation with World Health Organization classification
- Aortic Compliance in Patients with Aortic Regurgitation : Evaluation with Magnetic Resonance Imaging
- Hypervascular hepatocellular carcinoma : Combined dynamic MDCT and SPIO-enhanced MRI versus combined CTHA and CTAP
- Solitary pulmonary metastases from renal cell carcinoma : comparison of high-resolution CT with pathological findings
- Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors
- Renal Cortical Retention of Contrast Medium after Angiography as Assessed by Delayed CT: A Multivariate Analysis
- Analysis of entrance surface dose in general radiographies using body mass index classification
- A case of Type B3 thymoma in WHO classification
- A Hybrid Technique for Thickness-Map Visualization of the Hip Cartilages in MRI
- The respiratory motion analysis of the rib using 3-D images
- Sustained response to interferon-α plus ribavirin therapy for chronic hepatitis C is closely associated with increased dynamism of intrahepatic natural killer and natural killer T cells
- Response to Imatinib Mesylate in a Patient with Idiopathic Hypereosinophilic Syndrome Associated with Cyclic Eosinophil Oscillations
- Model-based Measurement of the Articular Cartilage Thickness in the Hip Joint
- Wavelet Encoded MR Imaging
- Intrahepatic Cholangiocarcinoma Arising 34 Years After Excision of a Type IV-A Congenital Choledochal Cyst : Report of a Case
- Splenic-intrahepatic left portal shunt in an adult patient with extrahepatic portal vein obstruction without recurrence after pancreaticoduodenectomy
- Management of Major Portosystemic Shunting in Small-for-Size Adult Living-Related Donor Liver Transplantation with a Left-Sided Graft Liver
- Automatic teeth recognition in multi-slice CT images (医用画像)
- Full-size Digital Storage Phosphor Chest Radiography : Effect of 4K versus 2K Matrix Size on Observer Performance in Detection of Subtle Interstitial Abnormalities
- 3D Imaging of Intraductal Spread of Breast Cancer and Its Clinical Application for Navigation Surgery
- Orientation Space Filtering for Multiple Orientation Line Segmentation
- Accuracy of feature-based 2D/3D registration for analyzing normal knee kinematics using X-ray fluoroscopy and CT images
- CT Colonographyにおける送気ガスの違いによる腸管拡張度に関する検討
- Clinicopathological analysis of CD133^+ and NCAM^+ human hepatic stem/progenitor cells in damaged livers and hepatocellular carcinomas