Active Blood Detection in a High Resolution Capsule Endoscopy using Auto Parameter Compensation method(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
スポンサーリンク
概要
- 論文の詳細を見る
Capsule Endoscopy(CE) is a new endoscopic system for convenient and accurate investigation of small bowel pathology including obscure gastrointestinal bleeding without invasive surgery. We have developed a technique to detect the bleeding automatically utilizing color spectrum transformation(CST). The detection method in this paper include parameter compensation step which compensate irregular image condition using color balance index. The feature value is extracted from each image and used in CST method as parameter compensation constant. Experimental results show the proposed method achieves (before patient adaptive method: 80.87%, 74.25% after patient adaptive method: 96.48%, 98.05%) of sensitivity and specificity.
- 社団法人電子情報通信学会の論文
- 2009-01-12
著者
-
Kim Jong
Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Me
-
Kim Jong
Inter-university Semiconductor Research Center Seoul National University:school Of Electrical Engine
-
Kim Jong
Seoul National Univ. Seoul Kor
-
Park Jung
Interdisciplinary Program In Radiation Applied Life Science Major Seoul National University
-
Lee Sang
Interdisciplinary Program in Radiation Applied Life Science, Seoul National University
-
Jung Yun
Interdisciplinary Program in Radiation Applied Life Science, Seoul National University
-
Lee Sang
Seoul National Univ. Seoul Kor
-
Lee Sang
Interdisciplinary Program In Radiation Applied Life Science Major Seoul National University
-
SONG Jeong
Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Me
-
Jung Yun
Interdisciplinary Program In Radiation Applied Life Science Major Seoul National University
-
Lee Dong
R & D Division Intromedic
-
Song Jeong
Interdisciplinary Program In Radiation Applied Life Science Major Seoul National University
-
Kim Young
R & D Division, IntroMedic
-
Lee Dong
R & D Division, IntroMedic
-
Yang Je
Dept. of Electronics and Computer Engineering, Hanyang University
-
Yang Je
Dept. Of Electronics And Computer Engineering Hanyang University
-
Kim Young
R & D Division Intromedic
-
Kim Jong
Inter-University Semiconductor Research Center and School of Electrical Engineering and Computer Science, Seoul National University, San 56-1, Sillim-dong, Gwanak-ku, Seoul 151-742, Republic of Korea
関連論文
- Multiscale Polyp Segmentation Algorithm in CT Colonography(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Automatic joint space measurement on the hand radiographs for rheumatoid arthritis(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Classification in Dynamic Contrast-enhanced Breast MRI : Comparison of Cluster-based approach and BI-RADS Criteria
- Comparative evaluation of segmentation methods for bronchial tree in the lung parenchyma
- Classification of urinary stone and vascular calcification in noncontrast CT using morphological analysis
- Optimal Selection of Operating Point for Hessian-based Polyp Detection Method in CT Colonography
- Analyses on Current Characteristics of 3-D MOSFET Determined by Junction Doping Profiles for Nonvolatile Memory Devices(Novel MOSFET Structures,Fundamentals and Applications of Advanced Semiconductor Devices)
- Analyses on Current Characteristics of 3-D MOSFET Nonvolatile Memory Devices Determined by Junction Doping Profiles(Session 7A Silicon Devices IV,AWAD2006)
- Analyses on Current Characteristics of 3-D MOSFET Nonvolatile Memory Devices Determined by Junction Doping Profiles(Session 7A Silicon Devices IV,AWAD2006)
- Analyses on Current Characteristics of 3-D MOSFET Nonvolatile Memory Devices Determined by Junction Doping Profiles
- Morphometry of 4D Eigen Spectral Images for Characterizing Spatio-temporal Properties of Intratumoral Enhancement Patterns in Dynamic Contrast-enhanced Breast MRI(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- 1-1) NEUROTOXICITY AND LONG LASTING ANALGESIA INDUCED BY CAPSAICINOIDS
- Design and Simulation of Asymmetric MOSFETs(Junction Formation and TFT Reliability,Fundamentals and Applications of Advanced Semiconductor Devices)
- Novel Gate-All-Around MOSFETs with Self-Aligned Structure
- Multi-Functionality of Novel Structured Tunneling Devices
- Design and Simulation of Asymmetric MOSFETs(Session 7A Silicon Devices IV,AWAD2006)
- Design and Simulation of Asymmetric MOSFETs(Session 7A Silicon Devices IV,AWAD2006)
- Design and Simulation of Asymmetric MOSFETs
- Active Blood Detection in a High Resolution Capsule Endoscopy using Auto Parameter Compensation method(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Classification of Benign/Malignant PNGGOs using K-means algorithm in MDCT Images : A Preliminary Study(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- ICONE11-36230 Analysis of steam line break of SMART using RETRAN-3D/INT
- 招待講演 Effect of Tube Current and Slice Thickness on CT Colonography, Computer-aided Detection Performance for Polyp Detection
- Fin and Recess-Channel Metal Oxide Semiconductor Field Effect Transistor for Sub-50 nm Dynamic Random Access Memory Cell
- Chemotherapy for Osteosarcoma in Korea
- Fabrication of Highly Scaled Silicon Nanowire Gate-All-Around Metal–Oxide–Semiconductor Field Effect Transistors by Using Self-Aligned Local-Channel V-gate by Optical Lithography Process
- Configuration estimation method for preliminary cost of ships based on engineering bills of materials
- Self-Aligned Asymmetric Metal–Oxide–Semiconductor Field Effect Transistors Fabricated on Silicon-on-Insulator
- Novel Gate-All-Around Metal–Oxide–Semiconductor Field Effect Transistors with Self-Aligned Structure