ICONE11-36230 Analysis of steam line break of SMART using RETRAN-3D/INT
スポンサーリンク
概要
- 論文の詳細を見る
RETRAN-3D has been modified to be suitable to safety analysis for integral type marine reactor with modular helical-coiled steam generator cassettes. The modified RETRAN-3D, RETRAN-3D/INT, has helical coil heat conductor model and heat transfer coefficient models for tube and shell sides of helical-coiled steam generator. In addition, moving models are added to simulate the effect of ship motions such as inclination, heaving, rolling and so on. RETRAN-3D/INT has been verified with natural circulation experiment conducted in Seoul National University and the analysis results for the first Japanese nuclear ship, MUTSU. In this study, the safety analysis for SMART, which has been developed by Korea Atomic Energy Research Institute, is performed to examine the applicability of RETRAN-3D/INT to the safety analysis of SMART. The steam line break is selected as a reference case. The break type is assumed to the guillotine break. The loss of offsite power is considered as a coincident event and the failure of single train of passive residual heat removal system is assumed as single failure. From the results, it is found that RETRAN-3D/INT can appropriately simulate the transient of SMART and the improvement of non-condensable gas model is required.
- 一般社団法人日本機械学会の論文
著者
-
Kim Jong
Seoul National Univ. Seoul Kor
-
Kim Jong
Seoul National University
-
Kim Tae
Seoul National University
-
Park Goon
Seoul National University
関連論文
- Multiscale Polyp Segmentation Algorithm in CT Colonography(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Automatic joint space measurement on the hand radiographs for rheumatoid arthritis(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Classification in Dynamic Contrast-enhanced Breast MRI : Comparison of Cluster-based approach and BI-RADS Criteria
- Comparative evaluation of segmentation methods for bronchial tree in the lung parenchyma
- Classification of urinary stone and vascular calcification in noncontrast CT using morphological analysis
- Optimal Selection of Operating Point for Hessian-based Polyp Detection Method in CT Colonography
- Morphometry of 4D Eigen Spectral Images for Characterizing Spatio-temporal Properties of Intratumoral Enhancement Patterns in Dynamic Contrast-enhanced Breast MRI(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- PE-215 The Proteinuria in the Hypertensive Patients with Previous Exposure to Agent Orange(PE036,Hypertension, Clinical 2 (H),Poster Session (English),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- Active Blood Detection in a High Resolution Capsule Endoscopy using Auto Parameter Compensation method(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- ICONE11-36230 Analysis of steam line break of SMART using RETRAN-3D/INT
- 招待講演 Effect of Tube Current and Slice Thickness on CT Colonography, Computer-aided Detection Performance for Polyp Detection
- ICONE11-36567 STUDY OF EARLY-PHASE THERMOHYDRAULIC CAPABILITIES OF MAAP4 THROUGH SIMULATION OF THETA EXPERIMENTS
- ICONE11-36271 The Verification of Subcooled Boiling Models in CFX-4.2 at Low Pressure in Annulus Channel Flow