Purpose: To evaluate the effects of tube current and slice thickness on CTC, CAD performance for polyp detection using pig phantoms. Conclusion: CAD performance for polyp detection on CTC is highly dependent on z-axis resolution. However, tube current is not an influencing factor on CAD performance at a given z-axis resolution.
- 社団法人電子情報通信学会の論文
- 2007-01-20
著者
-
Kim Hyo
Seoul National University College Of Medicine
-
Kim Jong
Seoul National Univ. Seoul Kor
-
Choi Byung
Seoul National Univ. Seoul Kor
-
Lee Jae
Seoul National Univ. Seoul Kor
-
Lee Jeong
Seoul National University Bundang Hospital
-
Kim Se
Seoul National Univ. Hospital Seoul Kor
-
Lee Jeong
Seoul National University Hospital Department Of Radiology:the Institute Of Radiation Medicine Ewha
-
Choi Jin
Seoul National University Hospital Department Of Radiology
-
Lee Jae
Seoul Children's Dental Center
-
Han Joon
Seoul National University Hospital Department Of Radiology:the Institute Of Radiation Medicine Ewha
-
Shin Cheong-Il
Seoul National University Hospital Department of Radiology
-
Lee Joon-Goo
Department of Medical Engineering, Ewha Womans University Hospital
-
Eun Hyo
Seoul National University, Ewha Womans University Hospital
-
Eun Hyo
Seoul National University Ewha Womans University Hospital
-
Kim Se
Seoul National University Hospital Department Of Radiology
-
Choi Byung
Seoul National University Hospital Department Of Radiology:the Institute Of Radiation Medicine Ewha
-
Kim Hyo
Seoul National University Hospital Department Of Radiology
-
Kim Jong
Seoul National University Hospital Department Of Radiology:the Institute Of Radiation Medicine Ewha
関連論文
- Multiscale Polyp Segmentation Algorithm in CT Colonography(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Intracoronary Continuous Adenosine Infusion : A Novel and Effective Way of Inducing Maximal Hyperemia for Fractional Flow Reserve Measurement
- DPE-003 Effects of Pitavastatin on High Density Lipoprotein Cholesterol and Cholesterol Ester Transfer Protein in Patients with Metabolic Syndrome(DPE01,Metabolic Syndrome (H),Digital Poster Session (English),The 73rd Annual Scientific Meeting of The Japa
- Automatic joint space measurement on the hand radiographs for rheumatoid arthritis(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Classification in Dynamic Contrast-enhanced Breast MRI : Comparison of Cluster-based approach and BI-RADS Criteria
- Comparative evaluation of segmentation methods for bronchial tree in the lung parenchyma
- Classification of urinary stone and vascular calcification in noncontrast CT using morphological analysis
- Optimal Selection of Operating Point for Hessian-based Polyp Detection Method in CT Colonography
- Improvement of Diagonally Weighted Space-Time Trellis Codes with Two Transmit Antennas by Using Unitary Rotation(Wireless Communication Technologies)
- 01P3-170 Status of Management for High-Alert Medications
- Morphometry of 4D Eigen Spectral Images for Characterizing Spatio-temporal Properties of Intratumoral Enhancement Patterns in Dynamic Contrast-enhanced Breast MRI(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Disparity of Perfusion and Glucose Metabolism of Epileptogenic Zones in Temporal Lobe Epilepsy Demonstrated by SPM/SPAM Analysis on ^O Water PET, [^F]FDG-PET, and [^Tc]-HMPAO SPECT
- Special Section on Multi-dimensional Mobile Information Networks
- Active Blood Detection in a High Resolution Capsule Endoscopy using Auto Parameter Compensation method(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- ICONE11-36230 Analysis of steam line break of SMART using RETRAN-3D/INT
- 招待講演 Effect of Tube Current and Slice Thickness on CT Colonography, Computer-aided Detection Performance for Polyp Detection
- Dental Service for Children with Disability in Seoul Children's Dental Center