Dust particles in hospital pharmacy were reduced to 1/10 to 1/50 by an electric vacuum cleaner placed near the source of dust. The dust removal rate in the area away from the cleaner was lower : 1/3 to 1/15. Dust particles produced in drug dispensing consisted of relatively large ones (1.0-5.0μm in diameter), and most of those due to other factors such as smoking and working personnel were smaller (0.3-0.5μm). Consequently, the ratio of large dust particles of 1.0-5.0μm was higher in pharmacy than in other places, and the ratio of small ones of 0.3-0.5μm was not so higher. When the vacuum cleaner was placed near the source of dust, most of the large particles parotids over 1.0-5.0μm were removed. Consequently, the particles of this size were reduced in any part of pharmacy. However, smaller particles of 0.3-0.5μm were not efficiently removed in the area distant from the cleaner : particles left unremoved in such area were 3 to 6 folds as many as in the place around the cleaner.
- 日本医療薬学会の論文
- 1980-11-20
著者
-
須原 清治
名古屋大学医学部付属病院薬剤部
-
須原 清治
名古屋大学医学部附属病院薬剤部
-
秋田 昌宏
名古屋大学医学部附属病院薬剤部
-
林 弘祐
名古屋大学医学部附属病院薬剤部
-
近藤 源作
名古屋大学医学部付属病院薬剤部
-
秋田 昌宏
名古屋大学医学部医療薬学・附属病院薬剤部
関連論文
- 血中テオフィリン動態の解析
- Homogeneous Enzyme Immunoassay法と高速液体クロマトグラフ法との対比
- 高速液体クロマトグラフ法による血漿中テオフィリンの測定
- 血漿中フェノバルビタール濃度に及ぼすゾニサミドの影響
- Pharmaceutical Evaluation of Carbamazepine Suppositories in Rats
- 血漿中ゾニサミド濃度に及ぼす併用薬の影響
- 14 カルバマゼピン坐剤の試製と薬剤学的評価
- アミノフィリン坐剤の直腸吸収
- パントシン注10%の配合変化試験
- 血漿中カルバマゼピン波度測定におけるSLFIA法の評価 : EMIT法およびHPLC法との比較
- 血漿中抗てんかん薬の測定におけるSLFIA法の臨床への適用 : HPLC法との比較
- 調剤による手指への微生物汚染
- 注射薬管理におけるカードセレクターの利用について
- 内用液剤の安定性におよぼす水質の影響
- グルタミン酸脱水素酵素の活性におよぼすトリエタノールアミンなどの影響
- 粗粒子添加による炭酸水素ナトリウムの粉体物性と混合性
- 各種機器稼動による調剤室内空中細菌への影響
- 調剤機器の騒音による調剤室職員への影響
- 粒子径等により物性を変えた医薬品に対する軽質無水ケイ酸の添加効果
- バレイショデンプンの諸物性におよぼす軽質無水ケイ酸の疎水化物並びに含有水分の影響
- 除塵機導入による調剤室内塵埃数の変化
- 硫酸ジベカシンの軟膏製剤化における安定性
- 調剤に用いる常水(薬剤をめぐる水の問題点とその対策)
- 各種滑沢剤を添加したバレイショデンプンの粉体物性に及ぼす含有水分の影響
- 錠剤の硬度および崩壊度の吸湿による経日変化