Clarification of Enhanced Hydroxyl Radical Production in Fenton Reaction with ATP/ADP Based on Luminol Chemiluminescence
スポンサーリンク
概要
- 論文の詳細を見る
Enhanced hydroxyl radical production in the Fenton reaction with ATP or ADP based on luminol chemiluminescence was clarified. Luminol chemiluminescence intensity increases with the concentration of ATP or ADP due to their influence on the Fenton reagents which produce hydroxyl radicals. Fenton reagents containing hydrogen peroxide and ferrous ion produce hydroxyl radicals which attack luminol and this emits light. The effect of ATP and ADP on the Fenton reaction is detected as luminol CL intensity with a photon counting system. This method allows measurement of ATP or ADP concentration ranging from 0 to 15 mM, which covers the physiological concentration range.
- 社団法人 化学工学会の論文
著者
-
SAKAI Kiyotaka
Department of Chemical Engineering, Waseda University
-
YAMAZAKI Makoto
Department of Animal Physiology and Nutrition, National Institute of Livestock and Grassland Science
-
Sakai Kiyotaka
Department Of Chemical Engineering Waseda University
-
Miyasaka Takehiro
Department of Health Care Science, Himeji Dokkyo University
-
Sakai K
Department Of Chemical Engineering Waseda University
-
Miyasaka Takehiro
Department Of Medical Engineering Himeji Dokkyo University
-
Aoyagi Satoka
Department Of Chemical Engineering Waseda University
-
Miyasaka Takehiro
Department Of Cardiovascular Physiology Olayama Graduate School Of Medicine Dentistry And Pharmaceut
-
Miyasaka Takehiro
Department Of Chemical Engineering Waseda University
-
Yamazaki M
Department Of Chemical Engineering Waseda University
-
Miyasaka Takehiro
Department Of Cardiovascular Physiology Okayama University Graduate School Of Medicine And Dentistry
-
SAKAI KIYOTAKA
Department of Applied Chemistry, Faculty of Science and Engineering, Waseda University
関連論文
- Carbonylation of oxyhemoglobin solution (HbO_2→HbCO) using a membrane oxygenator
- Effects of Fasting and Refeeding on Expression of Proteolytic-Related Genes in Skeletal Muscle of Chicks
- OE-201 Increasing Heart Rate Increased Residual Actin-Myosin Interaction without Raising End-diastolic Left Ventricular Pressure in Beating Rat Heart(OE34,Cardiac Function (Basic) (M),Oral Presentation (English),The 73rd Annual Scientific Meeting of The J
- FRS-114 Increasing preload attenuates crossbridge formation under hypoxia(New Concepts for Assessing Cardiac Function(M),Featured Research Session,The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- OE-202 Higher Heart Rate Attenuates the Actin-Myosin Interaction in LV Free Wall(Cardiac function, basic/clinical-1, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Transmurally Difference in Crossbridge Dynamics and Sarcomere Shortening during Relaxation of Isovolumic Beat(Cardiac Function, Basic/Clinical 3 (M), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- OE-194 Harmonized Transmural Crossbridge Formation during Contraction, but Discordant Crossbridge Decay during Relaxation Analyzed in Beating Rat Heart at SPring-8(Cardiac Function, Basic/Clinical 1 (M) : OE24)(Oral Presentation (English))
- Effects of Fasting and Refeeding on Expression of Atrogin-1 and Akt/FOXO Signaling Pathway in Skeletal Muscle of Chicks
- Effects of Orally Administrated Amino Acids on Myofibrillar Proteolysis in Chicks
- PJ-382 Real-time Monitoring of Cultured Myocytes Acidification at Different Temperature with Microsensor System Based on Ion-sensitive Field Effect Transistor(Metabolism/Biochemistry/Energetics 2 (IHD) : PJ64)(Poster Session (Japanese))
- PE-137 Comparison of Age-matched Endothelium-derived Relaxation Factors in Coronary Microcirculation between Normotensive and Spontaneously Hypertensive Rats : Direct In Vivo Visualization(Coronary Circulation, Basic/Clinical 1 (IHD) : PE24)(Poster Sessio
- OE-258 Land-mine explosion in capillary : direct in vivo observation of microbubble destruction with ultrasound(Echo/Doppler 12 (I) : OE32)(Oral Presentation (English))
- Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces
- MASS TRANSFER IN LAMINAR FLOWS AROUND SINGLE HOLLOW-FIBER MEMBRANES FOR HEMODIALYSIS
- FRS-085 Development of a Catheter-type Nitric Oxide Sensor for Coronary Sinus(NO and Cardiovascular System (H) : FRS10)(Featured Research Session (English))
- Visualisation of In-Vivo Renal Glomerular Microcirculation under DIC and Its Treatment by a PAF Inhibition and Heparin
- A trial to Evaluate Experimentally Induced Delayed Onset Muscle Soreness and Its Modulation by Vibration
- Development of a device for chemiluminescence determination of superoxide generated inside a dialysis hollow-fiber membrane
- A new reagentless immunosensor for measuring IgG concentration in human plasma based on fluorescence-enhancement immunoassay
- Clarification of Enhanced Hydroxyl Radical Production in Fenton Reaction with ATP/ADP Based on Luminol Chemiluminescence
- タンパク質吸着時の酵素固定化電極を用いた過渡電流による測定
- Technical evaluation of dialysate flow in a hollow-fiber dialyzer
- A biological role of the glycocalyx for shear-induced endothetium-derived nitric oxide production
- The First Alkali Metal Selenothioates: Synthesis and Molecular Structure
- Gate Effect of Cellulosic Dialysis Membrane Grafted with Molecularly Imprinted Polymer
- Transient Measurement of Glucose Using On-Off Controllable Enzyme Electrode with Polypyrrole Membrane
- ELECTROLUMINESCENCE OF INDIUM-TIN OXIDE IN AN ALKALINE SOLUTION OF HYDROGEN PEROXIDE
- CATHODIC ELECTROCHEMILUMINESCENCE OF LUMINOL ENHANCED BY ANTIBODY-ANTIGEN REACTION
- Development of an enzyme-free glucose sensor using the gate effect of a molecularly imprinted polymer
- Analysis of Reaction of Luminol at an Indium-Tin Oxide Anode by Cyclic Voltammetry
- Hollow-fiber blood-dialysis membranes : superoxide generation, permeation, and dismutation measured by chemiluminescence
- Electrochemiluminescent measurement of human serum albumin concentration in dialysate
- Optimum control of oxygen addinity of hemoglobin as an oxygen carrier solution for an artificial gill
- Computer-aided design of hollow-fiber dialyzers
- Feasibility of wearable artificial kidney using presently commercially available hollow-fiber membrane
- ACCUMULATION OF FRAZIL SLUSH AND VELOCITY DISTRIBUTION UNDER THE ICE COVER
- Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities
- Filtration characteristics of membranes for plasma separation and changes in membrane structure after blood contact.
- Structural analysis of hollow fiber dialysis membranes for clinical use.
- Determination of pore radius of hollow-fiber dialysis membranes using tritium-labeled water.
- Effects of Hematocrit on Filtrate Flux of Microporous Glass Membranes for Bovine Blood
- Removal estimation of middle molecular substances (MM) with high speed liquid chromatography.
- Therapeutic parameters for solute removal in hemodialysis.