Analysis of Reaction of Luminol at an Indium-Tin Oxide Anode by Cyclic Voltammetry
スポンサーリンク
概要
- 論文の詳細を見る
In the present study, cyclic voltammograms obtained with an indium-tin oxide (ITO) anode were compared with those obtained with a platinum anode. The peak currents generated by luminol oxidation at the platinum anode showed convex curves facing upwards with increasing luminol concentration, as the result of the prevention of the oxidation of the platinum electrode by the presence of luminol. With the ITO anode, no current due to electrode oxidation or reduction was detected. The peak current intensity of luminol oxidation was proportional to the luminol concentration, but the peak current was also in a linear relationship with the square root of the scan rate. However, the intercept current was largely deviated from zero. The deviation suggests radial diffusion of luminol at the ITO anode which has a small active point density. In conclusion, the ITO anode is useful for accurate measurement of the rate of luminol oxidation, but radial diffusion of luminol in the vicinity of the ITO surface should be taken into consideration in analysis of luminol oxidation.
- 社団法人 化学工学会の論文
著者
-
SAKAI Kiyotaka
Department of Chemical Engineering, Waseda University
-
Sakai Kiyotaka
Department Of Chemical Engineering Waseda University
-
Yoshimi Yasuo
Department Of Applied Chemistry Shibaura Institute Of Technology
関連論文
- Carbonylation of oxyhemoglobin solution (HbO_2→HbCO) using a membrane oxygenator
- Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces
- MASS TRANSFER IN LAMINAR FLOWS AROUND SINGLE HOLLOW-FIBER MEMBRANES FOR HEMODIALYSIS
- Development of a device for chemiluminescence determination of superoxide generated inside a dialysis hollow-fiber membrane
- A new reagentless immunosensor for measuring IgG concentration in human plasma based on fluorescence-enhancement immunoassay
- Clarification of Enhanced Hydroxyl Radical Production in Fenton Reaction with ATP/ADP Based on Luminol Chemiluminescence
- タンパク質吸着時の酵素固定化電極を用いた過渡電流による測定
- Technical evaluation of dialysate flow in a hollow-fiber dialyzer
- The First Alkali Metal Selenothioates: Synthesis and Molecular Structure
- Development of an artificial synapse using an electrochemical micropump
- Gate Effect of Cellulosic Dialysis Membrane Grafted with Molecularly Imprinted Polymer
- Transient Measurement of Glucose Using On-Off Controllable Enzyme Electrode with Polypyrrole Membrane
- ELECTROLUMINESCENCE OF INDIUM-TIN OXIDE IN AN ALKALINE SOLUTION OF HYDROGEN PEROXIDE
- CATHODIC ELECTROCHEMILUMINESCENCE OF LUMINOL ENHANCED BY ANTIBODY-ANTIGEN REACTION
- Development of an enzyme-free glucose sensor using the gate effect of a molecularly imprinted polymer
- Analysis of Reaction of Luminol at an Indium-Tin Oxide Anode by Cyclic Voltammetry
- Hollow-fiber blood-dialysis membranes : superoxide generation, permeation, and dismutation measured by chemiluminescence
- Electrochemiluminescent measurement of human serum albumin concentration in dialysate
- Optimum control of oxygen addinity of hemoglobin as an oxygen carrier solution for an artificial gill
- Computer-aided design of hollow-fiber dialyzers
- Chiral-Discriminative Gate Effect in Self-Supporting Phenylalanine-Imprinted Poly(Methacrylic Acid-co-2-Vinylpyridine-co-Triethyleneglycol Dimethacrylate) Membrane
- Feasibility of wearable artificial kidney using presently commercially available hollow-fiber membrane
- Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities