Gate Effect of Cellulosic Dialysis Membrane Grafted with Molecularly Imprinted Polymer
スポンサーリンク
概要
- 論文の詳細を見る
Graft copolymerization of ethyleneglycol dimethacrylate and merthacrylic acid onto cellulosic membrane was performed in the presence and absence of theophylline as the template for imprinting the copolymer molecularly. The effect of the presence of the template on the diffusive permeability of the grafted membrane was estimated by batch-wise dialysis of creatinine. The permeability of the theophylline-imprinted membrane was increased by the presence of theophylline, but was virtually unaffected by caffeine, which is an analogue of theophylline. The permeability of the non-imprinted grafted membrane decreased in the presence of theophylline or caffeine without discrimination. These results indicate that the diffusive permeability of the cellulosic membrane grafted with molecularly imprinted copolymer discriminates between the template and its analogue.
- 社団法人 化学工学会の論文
著者
-
SAKAI Kiyotaka
Department of Chemical Engineering, Waseda University
-
Hattori Koji
Department Of Cardiovascular Surgery Osaka City University Graduate School Of Medicine
-
Sakai K
Waseda Univ. Tokyo Jpn
-
Sakai Kiyotaka
Department Of Chemical Engineering Waseda University
-
Sakai Kiyotaka
Waseda University
-
YOSHIMI Yasuo
Department of Industrial Chemistry, Shibaura Institute of Technology
-
Hattori K
Department Of Chemical Engineering Waseda University
-
Yoshimi Yasuo
Department Of Industrial Chemistry Shibaura Institute Of Technology
-
Yoshimi Yasuo
Department Of Applied Chemistry Shibaura Institute Of Technology
-
Hattori Koji
Department Of Chemical Engineering Nagoya University
-
Hattori Koji
Department Of Applied Biological Sciences Saga University
-
SAKAI KIYOTAKA
Department of Applied Chemistry, Faculty of Science and Engineering, Waseda University
関連論文
- Carbonylation of oxyhemoglobin solution (HbO_2→HbCO) using a membrane oxygenator
- PJ-163 Automated Assessment of Left Ventricular Volume and Ejection Fraction by Real-time 3-dimensional Echocardiography with a New Automated Analysis Software(Echo/Doppler-12 (I) PJ28,Poster Session (Japanese),The 70th Anniversary Annual Scientific Meeti
- Bioabsorbable thread for tight tying of bones
- Mesenteric venous thrombosis associated with protein C deficiency
- Saccular True Aneurysm of the Ascending Aorta 19 Years After Aortic Cannulation : Report of a Case
- Off-pump coronary artery bypass surgery in a renal transplant patient
- Rapamycin as an inhibitor of osteogenic differentiation in bone marrow-derived mesenchymal stem cells
- Mycotic Aneurysm of the Distal Aortic Arch Caused by Aspergillus
- Orally Administered Benidipine and Manidipine Prevent Ischemia-Reperfusion Injury in the Rat Heart
- Early and Long-Term Results of Coronary Artery Bypass Grafting in Dialysis Patients
- Effectiveness and Toxicity Screening of Various Absorption Enhancers Using Caco-2 Cell Monolayers
- Raloxifene : its ossification-promoting effect on female mesenchymal stem cells
- Treatment of Kienbock's disease with cultured stem cell-seeded hybrid tendon roll interposition arthroplasty : experimental study
- Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces
- MASS TRANSFER IN LAMINAR FLOWS AROUND SINGLE HOLLOW-FIBER MEMBRANES FOR HEMODIALYSIS
- Unruptured Aneurysm of the Sinus of Valsalva With Behcet's Disease
- Aortic Aneurysm with Severe Aortic Regurgitation in a Patient with Systemic Lupus Erythematosus
- Anesthetic management of apicoaortic bypass in patients with severe aortic stenosis
- Autoimmune Pancreatitis Developing Remarkable Collateral Circulation Around the Pancreas
- Development of a device for chemiluminescence determination of superoxide generated inside a dialysis hollow-fiber membrane
- A new reagentless immunosensor for measuring IgG concentration in human plasma based on fluorescence-enhancement immunoassay
- Clarification of Enhanced Hydroxyl Radical Production in Fenton Reaction with ATP/ADP Based on Luminol Chemiluminescence
- タンパク質吸着時の酵素固定化電極を用いた過渡電流による測定
- Technical evaluation of dialysate flow in a hollow-fiber dialyzer
- Use of Heparin-coated Cardiopulmonary Bypass Circuit with Low-dose Heparin Reduces Postoperative Bleeding
- The First Alkali Metal Selenothioates: Synthesis and Molecular Structure
- Antibiotic Concentration of Shed Mediastinal Blood for Possible Reinfusion Following Cardiac Surgery
- Development of an artificial synapse using an electrochemical micropump
- Isolation of Plasmids from Brevibacterium(Microbiology & Fermentation Industry)
- Gate Effect of Cellulosic Dialysis Membrane Grafted with Molecularly Imprinted Polymer
- Transient Measurement of Glucose Using On-Off Controllable Enzyme Electrode with Polypyrrole Membrane
- ELECTROLUMINESCENCE OF INDIUM-TIN OXIDE IN AN ALKALINE SOLUTION OF HYDROGEN PEROXIDE
- CATHODIC ELECTROCHEMILUMINESCENCE OF LUMINOL ENHANCED BY ANTIBODY-ANTIGEN REACTION
- Development of an enzyme-free glucose sensor using the gate effect of a molecularly imprinted polymer
- BM-O6 A glucose sensor using gate effect of molecularly imprinted polymer grafted on electrode(Section III Biomedical Engineering)
- Analysis of Reaction of Luminol at an Indium-Tin Oxide Anode by Cyclic Voltammetry
- Hollow-fiber blood-dialysis membranes : superoxide generation, permeation, and dismutation measured by chemiluminescence
- Electrochemiluminescent measurement of human serum albumin concentration in dialysate
- Optimum control of oxygen addinity of hemoglobin as an oxygen carrier solution for an artificial gill
- Computer-aided design of hollow-fiber dialyzers
- Chiral-Discriminative Gate Effect in Self-Supporting Phenylalanine-Imprinted Poly(Methacrylic Acid-co-2-Vinylpyridine-co-Triethyleneglycol Dimethacrylate) Membrane
- Feasibility of wearable artificial kidney using presently commercially available hollow-fiber membrane
- SEDIMENTATION BEHAVIOR OF PROTEIN SOLUTIONS IN ULTRACENTRIFUGATION FIELD
- EVALUATION OF DEAD-END ULTRAFILTRATION PROPERTIES BY ULTRACENTRIFUGATION METHOD
- Endovascular Repair of Sealed Rupture of a Thoracic Inflammatory Aneurysm that Developed after Corticosteroid Therapy
- Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities
- Left Coronary Ostial Stenosis after the Modified Bentall Using a Long Interposed Coronary Graft in a Patient with Pectus Excavatum
- Mitral Valve Repair in a Patient with Mesocardia
- Filtration characteristics of membranes for plasma separation and changes in membrane structure after blood contact.
- Structural analysis of hollow fiber dialysis membranes for clinical use.
- Determination of pore radius of hollow-fiber dialysis membranes using tritium-labeled water.
- Effects of Hematocrit on Filtrate Flux of Microporous Glass Membranes for Bovine Blood
- Removal estimation of middle molecular substances (MM) with high speed liquid chromatography.
- Therapeutic parameters for solute removal in hemodialysis.