Therapeutic parameters for solute removal in hemodialysis.
スポンサーリンク
概要
- 論文の詳細を見る
This paper discusses a new quantitative evaluation of the removal dynamics in the artificial kidney system. New therapeutic parameters (KC/V and CL/V) were introduced into the evaluation. By means of these parameters, which can be determined by simulation analysis, concentration-time profiles of each patient could be drawn during dialysis and off-dialysis periods. The newly defined concept of "CSMAX", which means a maximum solute concentration in stable periods, is presented as the characterization parameter in long-term treatment.
- 公益社団法人 化学工学会の論文
著者
関連論文
- Carbonylation of oxyhemoglobin solution (HbO_2→HbCO) using a membrane oxygenator
- Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces
- MASS TRANSFER IN LAMINAR FLOWS AROUND SINGLE HOLLOW-FIBER MEMBRANES FOR HEMODIALYSIS
- Development of a device for chemiluminescence determination of superoxide generated inside a dialysis hollow-fiber membrane
- A new reagentless immunosensor for measuring IgG concentration in human plasma based on fluorescence-enhancement immunoassay
- Clarification of Enhanced Hydroxyl Radical Production in Fenton Reaction with ATP/ADP Based on Luminol Chemiluminescence
- Technical evaluation of dialysate flow in a hollow-fiber dialyzer
- The First Alkali Metal Selenothioates: Synthesis and Molecular Structure
- Gate Effect of Cellulosic Dialysis Membrane Grafted with Molecularly Imprinted Polymer
- Transient Measurement of Glucose Using On-Off Controllable Enzyme Electrode with Polypyrrole Membrane
- ELECTROLUMINESCENCE OF INDIUM-TIN OXIDE IN AN ALKALINE SOLUTION OF HYDROGEN PEROXIDE
- CATHODIC ELECTROCHEMILUMINESCENCE OF LUMINOL ENHANCED BY ANTIBODY-ANTIGEN REACTION
- Development of an enzyme-free glucose sensor using the gate effect of a molecularly imprinted polymer
- Hollow-fiber blood-dialysis membranes : superoxide generation, permeation, and dismutation measured by chemiluminescence
- Electrochemiluminescent measurement of human serum albumin concentration in dialysate
- Optimum control of oxygen addinity of hemoglobin as an oxygen carrier solution for an artificial gill
- Feasibility of wearable artificial kidney using presently commercially available hollow-fiber membrane
- Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities
- Filtration characteristics of membranes for plasma separation and changes in membrane structure after blood contact.
- Structural analysis of hollow fiber dialysis membranes for clinical use.
- Determination of pore radius of hollow-fiber dialysis membranes using tritium-labeled water.
- Effects of Hematocrit on Filtrate Flux of Microporous Glass Membranes for Bovine Blood
- Removal estimation of middle molecular substances (MM) with high speed liquid chromatography.
- Therapeutic parameters for solute removal in hemodialysis.