Efficient Generation of Cavitation Bubbles in Gel Phantom by Ultrasound Exposure with Negative-Followed by Positive-Peak-Pressure-Emphasized Waves
スポンサーリンク
概要
- 論文の詳細を見る
Cavitation bubbles have much potential for emphasizing therapeutic treatments such as high-intensity focused ultrasound (HIFU) treatment, histotripsy, and sonodynamic therapy. Their highly efficient as well as controlled generation is important to utilize them effectively as well as safely. However, producing negative pressure over the cavitation threshold by focused ultrasound is difficult because of the nonlinear propagation combined with the focal phase shift. We have suggested a dual-frequency ultrasound exposure method, in which N- and P-waves emphasizing either the peak negative or positive pressure, respectively, are synthesized by superimposing the second harmonic onto the fundamental frequency. In this study, high-speed camera observation demonstrated that the exposure with N-waves immediately followed by P-waves could generate cavitation bubbles most efficiently in gel phantom. Furthermore, the measured negative and positive pressure distributions of the N- and P-wave fields, respectively, agreed well with the optically observed distributions of cavitation inception and cavitation cloud growth.
- 2013-07-25
著者
-
Yasuda Jun
Graduate School Of Medicine Tohoku University
-
Umemura Shin-ichiro
Graduate School of Bioengineering, Tohoku University, 6-6 Aoba, Aramaki, Aoba-ku, Sendai 980-8579, Japan
-
Yoshizawa Shin
Graduate School of Engineering, Tohoku University, Sendai 980-5879, Japan
-
Asai Ayumu
Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
関連論文
- Analysis of High-Intensity Focused Ultrasound Source Using Time Reversal: Effect of Lamb-Like Waves
- Ultrasonic coagulation of large tissue region by generating multiple cavitation clouds in direction perpendicular to ultrasound propagation (Special issue: Ultrasonic electronics)
- Phase Change Nanodroplets and Microbubbles Generated from Them as Sources of Chemically Active Cavitation
- Quantitative Measurement of Focused Ultrasound Pressure Field Using Subtraction Shadowgraph
- Breathing-Mode Ceramic Element for Therapeutic Array Transducer
- Inference of microRNA transfection via target gene expression
- Staircase-Voltage Metal–Oxide–Semiconductor Field-Effect Transistor Driver Circuit for Therapeutic Ultrasound
- Sustaining Microbubbles Derived from Phase Change Nanodroplet by Low-Amplitude Ultrasound Exposure
- Acoustic Response of Microbubbles Derived from Phase-Change Nanodroplet
- Therapeutic Array Transducer Element Using Coresonance between Hemispherical Piezoceramic Shell and Water Sphere: Effect of Load Masses of Support and Electric Contact
- Enhancement of Localized Heating by Ultrasonically Induced Cavitation in High Intensity Focused Ultrasound Treatment
- Coagulation of Large Regions by Creating Multiple Cavitation Clouds for High Intensity Focused Ultrasound Treatment
- Efficient Generation of Cavitation Bubbles in Gel Phantom by Ultrasound Exposure with Negative-Followed by Positive-Peak-Pressure-Emphasized Waves
- Large Volume Coagulation Utilizing Multiple Cavitation Clouds Generated by Array Transducer Driven by 32 Channel Drive Circuits
- Optical Phase Contrast Mapping of Highly Focused Ultrasonic Fields
- Analysis of Temperature Rise Induced by High-Intensity Focused Ultrasound in Tissue-Mimicking Gel Considering Cavitation Bubbles
- Enhancement of Focused Ultrasound Treatment by Acoustically Generated Microbubbles
- Analysis of Temperature Rise Induced by High-Intensity Focused Ultrasound in Tissue-Mimicking Gel Considering Cavitation Bubbles