炎光および原子吸光分析法によるイットリウムの定量
スポンサーリンク
概要
- 論文の詳細を見る
In order to study the determination of yttrium by the flame emission and atomic absorption spectrometry using nitrous oxide-acetylene flame, the effects of several inorganic acids, common metal ions, and rare earth elements on the intensities of the emission and absorption of yttrium were investigated in detail. The experimental conditions are as follows: the analytical lines are 4077 Å or 4102 Å in the flame emission method, and 4102 Å in the atomic absorption method; the nitrous oxide gas flow rate, 6.7 <I>l</I>/min, and the acetylene gas flow rate, 4.6 <I>l</I>/min in both methods.<BR>The effects of several inorganic acids, common metal ions, and rare earth elements on the intensities of the emission and absorption of yttrium (200 ppm) are shown in Fig. 2, Fig. 3, and Fig. 4, respectively. As shown in Fig. 2, the intensities of the emission and absorption of yttrium decrease gradually with increasing concentration of hydrochloric acid; they increase in the presence of each of 0.31 <I>M</I> nitric acid, 10<SUP>-3</SUP>3<I>M</I> perchloric acid, 10<SUP>-3</SUP>1 <I>M</I> sulfuric acid, and 10<SUP>-3</SUP>1 <I>M</I> phosphoric acid; they decrease in the presence of each of 3 <I>M</I> sulfuric acid and 3 <I>M</I> phosphoric acid. As shown in Fig. 3, they increase in the presence of high concentration (300010000 ppm) of each of Li, Na, K, Mg, Ca, Sr, Ba, Cr, Mn, Fe, Ni, Cu, Zn, and Pb; they decrease considerably in the presence of high concentration(300010000 ppm)of aluminum. As shown in Fig. 4, they increase with increasing concentration of each of the rare earth elements.<BR>The calibration curves for yttrium in the concentration range of 20500 ppm are prepared by both methods (Fig. 5 and Fig. 6). The calibration curves for yttrium alone are not linear but concave in both methods. Those obtained by adding 10000 ppm of potassium are convex in the flame emission method, and linear in the atomic absorption method. Those obtained by adding 10000 ppm of lanthanum are convex in both methods.<BR>The determination of yttrium in synthetic samples consisting of heavy rare earth mixtures (Gd, Tb, Dy, and Ho) and 0.130% of Y<SUB>2</SUB>O<SUB>3</SUB> is performed by both methods. The found values of yttrium by both methods are in fair agreement with the theoretical values. In the determination of yttrium in real samples, the values (0.222% as Y<SUB>2</SUB>O<SUB>3</SUB>) obtained by both methods agree well, and the precision (coefficients of variation) is 0.94.9% in the flame emission method, and 1.17.1 % in the atomic absorption method.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 水素型陽イオン交換樹脂を用いるリン酸イオンのイオン排除クロマトグラフィー
- グラッシーカーボン中間体を用いる気固クロマトグラフィー
- グラッシーカーボンを用いる気固クロマトグラフィー
- 不活性ガス融解法による酸化物系セラミックス中酸素の定量 : 浴金属の効果
- ファインセラミックスの不純物分析技術
- 水素型陽イオン交換樹脂による陰イオンの電量検出型液体クロマトグラフィー
- 電量検出型液体クロマトグラフによる有機酸の定量;ブチルアルコールの活性汚でいによる分解過程への応用
- グラッシーカーボン電極の発光分光分析への応用
- Compact Atomcomterによる電極形状と再現性の検討
- 炭化ケイ素粉末中遊離炭素の定量
- 加圧酸分解 : 原子吸光分析法による窒化ケイ素中塩素の定量
- 二価イオンスペクトルを用いる二次イオン質量分析法による希土類元素の定量
- 溶存酸素の電気化学的測定法
- 隔膜電極を用いる溶存酸素の測定法
- ホウケイ酸ガラス中のホウ素の電流滴定法
- 原子吸光分析法による酸化イットリウムおよび硫化酸化イットリウム中の銅,鉄,鉛,亜鉛の定量
- 炎光および原子吸光分析法によるネオジム,ユーロピウム,ガドリニウム,エルビウムの定量
- 炎光,原子吸光分析法による酸化イットリウム中のナトリウム,マグネシウム,カルシウムの定量
- 炎光および原子吸光分析法によるイットリウムの定量
- イオンマイクロアナライザによる希土酸化物の定量分析
- レーザーマイクロプロープによる発光分析