連続水素化物発生-誘導結合プラズマ発光分析法による銀めっき液中のセレンの定量
スポンサーリンク
概要
- 論文の詳細を見る
Determination of selenium in silver plating solution was studied by automated hydride generation-ICP-AES (HG-ICP-AES). The sample was decomposed with nitric and sulfuric acids. Loss of selenium by volatilization during decomposition was not observed. Selenium was seperated prior to the analysis by distillation as the bromide in order to eliminate the effect of coexisting elements. Both selenium (IV) and (VI) were quantitatively recovered by this distillation. In the plating solution, there were large amounts of coexisting elements, but these elements did not interferece with the distillation of selenium. Selenium in the distillate was determined by HG-ICP-AES. This method was applied to the determination of selenium in actual silver plating solutions. The recoveries of this method were 96〜104% and the analytical results were in good agreement with those from the spectrophotometric method. The relative standard deviations were 1.5〜4.3%.
- 1987-01-05
著者
関連論文
- テルル共沈・イオン交換分離/黒鉛炉原子吸光法による銅, 鉄, ニッケル含有鉱石中の貴金属の定量
- 加圧酸分解/誘導結合プラズマ発光分析法による触媒中の白金,パラジウム,ロジウムの定量
- 連続水素化物発生-誘導結合プラズマ発光分析法による銀めっき液中のセレンの定量
- 加圧酸分解 : 誘導結合プラズマ発光分析法による触媒中のイリジウムの定量
- ヨウ化カリウムを用いた電位差滴定法による触媒中のパラジウム(II)の定量
- 内標準を用いる誘導結合プラズマ発光分析法による触媒中の白金族元素の定量
- 誘導結合プラズマ発光分析法による触媒中の白金,ロジウムの定量
- 連続水素化物発生/誘導結合プラズマ発光分析法による石炭及びフライアッシュ中のヒ素及びセレンの定量
- 塩化物イオンと共存するパラジウム(II)の金めっき白金電極を用いた電位差滴定
- 硝酸銀を用いた電位滴定法によるシアン化物イオンとジシアノ銀酸イオンの逐次定量
- 塩素定量のための貴金属化合物の分解法の検討