Change in Double Product during Stepwise Incremental Exercise
スポンサーリンク
概要
- 論文の詳細を見る
The purpose of this study was to observe the change in double product with increases in the intensity of bicycle exercise. Eleven young male adults participated in this study. The subjects performed graded bicycling exercise increasing 20 watts every 2 min from 0 watts until the heart rate (HR) reached 170beats-min^<-1>. During exercise systolic blood pressure (SBP) and HR were continuously measured. Initially SBP gradually increased with the increase in workload, but when the intensity of exercise became even higher, the rate of increase slowed. On the other hand, the increase in HR was very small during the initial 5 min of exercise and when the intensity of exercise increased, the rate of increase of HR became higher. The polygonal regression analyses on the relation of double product to elapsed time revealed clear break-points. On average, the break-point of double product was 6.6 min (56 watts). These results clearly showed that the break-point of double product with an increase in workload appeared even though the workload was relatively low.
- 日本生理人類学会の論文
著者
-
Yamasaki M
Hiroshima Univ.
-
Yamasaki Masahiro
Department Of Bioregulation. Institute For Medical Genetics Kumamoto University Medical School
-
Choi Seung
Department of Medicine, Cardiac and Vascular Center, Cardiovascular Imaging Center, Samsung Medical
-
Choi S
Department Of Sports Science Sungshin Women's University Seoul Korea
-
Takahashi Kazufumi
Graduate School Of Education Hiroshima University
-
Kim K
Graduate School Of Biosphere Science Hiroshima University
-
Yamasaki Masahiro
Graduate School Of Biosphere Science Hiroshima University
-
Kim Kyu
Graduate School of Biosphere Science, Hiroshima University
-
Kurokawa Takashi
Graduate School of Education, Hiroshima University
-
Kurokawa T
Hiroshima Univ.
-
Choi Seung
Department Of Applied Chemistry Konkuk University
-
YAMAZAKI M
Graduate School of Biosphere Science, Hiroshima University
関連論文
- Molecular Characteristics of Bovine Serum Albumin-Dextran Conjugates
- Characteristics of people with challenge using two different sports facilities in Japan
- Three-Dimensional Quantitative Volumetry of Chronic Total Occlusion Plaque Using Coronary Multidetector Computed Tomography
- Effect of a Simulated Saturation Dive to 31 ATA on Pulmonary Function
- 14 Postural and Intentional Tremor during a Simulated Oxygen-helium Dive to 300m
- 11 Influence of Hyperbaric Heliox Environment (31 ATA and He-0_2) on Microvibration and Electroencephalogram
- Influence of Hyperbaric Heliox Environment at 31ATA on Microvibration and Electroencephalogram in Four Divers
- Power Spectral Analysis of Intentional and Postural Tremor During a Simulated Heliox Dive to 31ATA
- IS-16 The clinical relevance of the Survivin expression and the Loss of Heterozygosity in Neuroblastoma
- Effects of Upper Limb Exercise on Thermoregulatory Responses in Patients with Spinal Cord Injury
- Usefulness of a simple device to measure aural canal temperature
- A Statistical Approach to Error Compensation in Spectral Quantization(Speech and Hearing)
- Work Efficiency of Paraplegics during Arm Cranking Exercise
- Relationship between Heart Rate and Oxygen Uptake during Submaximal Arm Cranking in Paraplegics and Quardriplegics
- Effects of aerobic and resistance training on the health-related physical fitness and serum lipids in elderly women
- Change in Double Product during Stepwise Incremental Exercise
- Characteristics of Body Heat Balance of Paraplegics during Exercise in a Hot Environment
- Effect of Wearing Clothes on Oxygen Uptake and Ratings of Perceived Exertion while Swimming
- Relationship of Sports Participation to Formation of pressure Sore in Spinai Cord injured Persons
- Synthesis and Characterization of Branched Sulfonated Poly(ether sulfone ketone) as Proton Exchange Membrane
- The results of antegrade continence enema using a retubularized sigmoidostomy
- Waveform Measurement of Ultra-Short Optical Pulses Based on Two-Photon Absorption in Si-Image Sensor
- VW12. One-stage Soave Operation during the Last Seven Years : Results and Operative Technique
- 14-12.The study of comparison of first and second trimester screening for fetal anomalies (Session 15 Perinatology 4)
- Isoflavones Found in Korean Soybean Paste as 3-Hydroxy-3-methylglutaryl Coenzyme A Reductase Inhibitors
- 3A13 ESOPHAGEAL ATRESTA WITH DISTAL TRACHESOPHAGEAL FISTULA : SHORT EXPERIENCE
- Three-Dimensional Quantitative Volumetry of Chronic Total Occlusion Plaque Using Coronary Multidetector Computed Tomography
- Fiber Transmission Characteristics of Parabolic Pulses Generated by Optical Pulse Synthesizer
- Generation of Phase Only Pulses Using Optical Pulse Synthesizer
- I-4 Redo-pull through operation for Hirschsprung's disease
- Fiber Transmission Characteristics of Optical Short Pulses Generated by Optical Pulse Synthesizer
- Supercontinuum Comb Generation Using Optical Pulse Synthesizer and Highly Nonlinear Dispersion-Shifted Fiber
- Power Line Monitoring System Using Fiber Optic Power Supply
- Intestinal Tritrichomonas suis (= T. foetus) Infection in Japanese Cats
- Daily Energy Expenditure in Active and Inactive Persons with Spinal Cord Injury
- Effect of pre-exercise caffeine ingestion on cardiovascular and metabolic responses in persons with spinal cord injury
- Health-Related Quality of Life in Active Persons with Spinal Cord Injury
- Correlation Between Circulating Angiogenic Cell Mobilizations and Recovery of Coronary Flow Reserve in Patients With Acute Myocardial Infarction
- Fiber transmission characteristics of phase only pulse and its dispersion compensation in high power regime
- 3A19 THE USE OF ENZYME REPLACEMENT THERAPY IN THE TREATMENT OF GAUCHER'S DISEASE
- Resolution and Noise Factor of Distance Measurement Using Two-Photon Absorption Process in Photodetector
- 1 MHz-Resolution Spectroscopy Based on Light Frequency Sweeping Using a Single-Sideband Optical Modulator
- Multicarrier Light Source with 50 GHz Spacing and Its Application in Dense Wavelength Division Multiplexing System
- Frequency-Comb-Based Interference Microscope with a Line-Type Image Sensor
- Application of Faraday Rotator Reflector and Faraday Rotator Transmitter to Profilometry and Tomography
- Qualitative and Quantitative Contrast Enhanced Ultrasonography of the Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal Dogs
- HOW THE NUMBER OF YEARS OF SPORTS EXPERIENCE AND THE FREQUENCY OF SPORTS ACTIVITIES CAN INFLUENCE THE QUALITY OF LIFE OF PEOPLE WITH CHALLENGES
- Synthesis and Characterization of Y2O3:Eu Phosphor Derived by Solution-Combustion Method
- Health-Related Quality of Life in Active Persons with Spinal Cord Injury