Investigation about Data Reduction and Sedimentation Distance of Sedimentation Balance Method
スポンサーリンク
概要
- 論文の詳細を見る
The Sedimentation balance type particle size analyzer is improved. The slurry supply device was automated and the height of peripheral wall of the detective tray was raised. As a result we can acquire data of the sedimentation mass change accurately. Moreover, the ratio of measured total sedimentation mass to the theoretical total sedimentation mass was kept constant ranging from 1.00 to 1.02 independent of particle size. By the above improvement, we can develop a more precious sedimentation balance.Twomey’s non-linear iteration method was applied to retrieve a particle size distribution from the sedimentation curve measured with a sedimentation balance method. It is found that the non-linear iteration method can calculate size distributions accurately.Furthermore, the influence of the thickness at the base of the detective tray on the sedimentation distance was also investigated. As a result, it is clarified that the change in detected mass did not depend on thickness at the base of the tray. Therefore, it is concluded that the sedimentation distance in the sedimentation balance method should be defined as the distance between the lower surface of the base of the tray and suspension surface.
- 社団法人 化学工学会の論文
著者
-
Yoshida Hideto
Department Of Chemical Engineering Graduate School Of Engineering Hiroshima University
-
Fukui Kunihiro
Department Of Chemical Engineering Hiroshima University
-
Fukui Kunihiro
Department Of Applied Physics Faculty Of Science Tokyo University Of Education
-
Yoshida Hideto
Department Of Chemical Engineering Hiroshima University
-
SHIBA Mitsuya
Department of Chemical Engineering, Hiroshima University
-
TOKUNAGA Yuusuke
Department of Chemical Engineering, Hiroshima University
-
Shiba Mitsuya
Department Of Chemical Engineering Hiroshima University
-
Tokunaga Y
Department Of Chemical Engineering Hiroshima University
関連論文
- Effect of Inlet Duct Shape on Particle Separation Performance of Cyclone Separator
- Particle size measurement of standard reference particle candidates and theoretical estimation of uncertainty region
- Enhancement of the Classification Performance of Electrical Field-Flow Fractionation Using Horizontal Electrophoresis
- Influence of inlet flow rate, pH, and beads mill operating condition on separation performance of sub-micron particles by electrical hydrocyclone
- Rapid and simultaneous determination of multi-element abundances and U-Pb age for zircon crystal using UV laser ablation ICP-MS technique: critical evaluation of the technique with 91500 zircon standard
- Particle size measurement of standard reference particle candidates with improved size measurement devices
- Effects of initial slurry concentration distribution on the particle size distribution measured with a sedimentation balance method
- Synthesis of indium tin oxide powder by solid-phase reaction with microwave heating
- Continuous fine particle classification by water elutriator with applied electro-potential
- Utilization of NaCl for phillipsite synthesis from fly ash by hydrothermal treatment with microwave heating
- Classification of Particles Dispersed by Bead Milling Using Electrical Field-Flow Fractionation
- Effect of Multi-Inlet Flow on Particle Classification Performance of Hydro-Cyclones and New Estimating Equation
- Effects of microwave irradiation on the crystalline phase of zeolite synthesized from fly ash by hydrothermal treatment
- Effect of particle properties on the morphological change induced by impaction against a solid surface for tristearin powder mixed with hard particles
- Fluorine-Doped Indium Oxide Thin Films Prepared by Chemical Vapor Deposition
- Investigation about Data Reduction and Sedimentation Distance of Sedimentation Balance Method
- Phillipsite synthesis from fly ash prepared by hydrothermal treatment with microwave heating
- Effect of apex cone height on particle classification performance of a cyclone separator
- Influence of wall properties on the morphological change of Sb_2O_3 fine particles induced by impaction against a wall
- Particle size measurement with an improved sedimentation balance method and microscopic method together with computer simulation of necessary sample size
- Particle Separation with a Hydro-Cyclone Separator in a Wet Limestone Gypsum FGD Process
- Separation of Unburned Carbon in Fly Ash Particles Using Special Louver Separator
- Classification of Particles Dispersed by Bead Milling Using Electrical Field-Flow Fractionation
- Meteor Storm Activity and Average Size of Meteoroids for the 2001 Leonids by FM Broadcasting Radio Observation
- Effect of Blade Angle on Crystallinity Change in a Mechanical Impact Mill
- Comparison of separation performance between single and two inlets hydrocyclones
- Theoretical calculation of fundamental uncertainty region based on the maximum and/or the minimum size in the preparation of standard reference particles for particle size measurement
- Enhancement of the Classification Performance of Electrical Field-Flow Fractionation Using Horizontal Electrophoresis
- Radial Modes of Plasma Waves
- Classification of particles by centrifugal separator and analysis of the fluid behavior
- Environmental Transmission Electron Microscopy Observations of Swinging and Rotational Growth of Carbon Nanotubes
- Separation of Unburned Carbon in Fly Ash Particles Using Special Louver Separator
- Carbon Beads on Semiconductor Nanowires
- Size classification of submicron powder by air cyclone and three-dimensional analysis.
- The effect of initial parameters on particle size distribution inverted using the laser diffraction technique and a non-linear iterative method
- Theoretical calculation of uncertainty region based on the general size distribution in the preparation of standard reference particles for particle size measurement