Measurement of Effective Renal Plasma Flow (ERPF) with 123I - Orthoiodohippurate (I - 123 - OIH)
スポンサーリンク
概要
著者
-
古嶋 昭博
熊本大学生命資源研究支援センター
-
TOMIGUCHI Seiji
Department of Diagnostic Radiology, School of Health Sciences, Kumamoto University
-
Kojima Akihiro
Institute Of Resource Development And Analysis Kumamoto University
-
Kojima Akihiro
Department Of Radiology Kumamoto Unviersity School Of Medicine
-
Kojima Akihiro
Department Of Cardiology Takamatsu Municipal Hospital
-
TAKAHASHI Mutsumasa
Department of Radiology, Kumamoto Unviersity School of Medicine
-
TSUJI Akinori
Department of Radiology, Kumamoto University School of Medicine
-
Tsuji Akinori
Department Of Radiology Kumamoto University School Of Medicine
-
Tomiguchi Seiji
Department Of Diagnostic Radiology School Of Health Sciences Kumamoto University
-
Tomiguchi Seiji
Department Of Radiology Kumamoto University School Of Medicine
-
Takahashi Mutsumasa
Department Of Radiology Kumamoto Unviersity School Of Medicine
-
Takahashi Mutsumasa
Department Of Pharmacy Kumamoto University Hospital:first Department Of Surgery Kumamoto University
-
Takahashi Mutsumasa
Department Of Radiology Kumamoto University School Of Medicine
-
Takaki Yoshikazu
Departments Of Radiology Kumamoto University School Of Medicine
-
Nakashima Rumi
Department Of Radilogy Kumamoto University School Of Medicine
-
Takahashi Mutsumasa
Department Of Radilogy Kumamoto University School Of Medicine
-
Tomiguchi Seiji
Department Of Radilogy Kumamoto University School Of Medicine
-
Tomiguchi Seiji
Department Of Radiology Kumamoto Unviersity School Of Medicine
関連論文
- 核医学イメージング実験のための面線源ファントムの作製に関する研究 : 第1報 : ラミネート加工した紙面線源作製法とその有効性に関する検討
- 心筋SPECT検査におけるcollimator detector response(CDR)補正とeffective scatter source estimation(ESSE)法による散乱線補正の有用性
- 多施設による ^Tc-MAG_3 腎機能定量解析精度の検討
- 座談会 遠隔画像診断
- 141 高エネルギー電子線と光子による平行平板電離箱の校正定数の評価
- 139 電子線の吸収線量測定における平行平板形電離箱の擾乱補正係数の評価
- 136 乳房温存療法における接線照射の線量評価
- 62 非対称照射野のモニタユニットの計算
- 放射線治療における非対称照射野の線量評価
- 423 DSAにおける被曝線量と画質について : 第2報 皮膚入射線量一定での管電圧と画質の関係
- 422 DSAにおける被曝線量と画質について : 第1報 管電圧一定でのI.I.入射線量と画質の関係
- ^Tl 心筋 SPECT におけるトランスミッション・エミッションデータ同時収集法の評価
- 19.胸部単純撮影で検出し得なかった肺高分化型腺癌の2例(第35回日本肺癌学会九州支部会)
- エネルギースペクトルとイメージによる二核種同時収集における crosstalk 率の測定
- 加齢, 喫煙が肺に及ぼす影響 -^I-IMP dynamic scintigraphy による検討 -
- 定量的な放射性タリウムイメージングのためのコリメータ選択
- 虚血性心疾患における^Tc-tetrofosmin (PPN 1011) 心筋 SPECT の検討
- 5. CTガイド下肺生検の検討(第33回 日本肺癌学会九州支部会)
- 胃憩室の検討
- 急速に進展した胃粘膜下腫瘍(angiosarcoma)の1例
- 最近2年間の間接胃集検フィルムの示現能・読影能
- 高濃度バリウム(180W/V%)の胃集検への使用試み
- 頭頸部腫瘍の放射線治療効果判定におけるT1-201 SPECTの有用性について
- PS-096-4 CT/SPECT combined systemによるsentinel lymph nodeの3次元的Navigation
- 低線量ラセンCTによる肺癌検診にて発見された肺葉内肺分画症の一例
- Role of cardiac computed tomography in patients with suspected coronary artery disease : interaction with nuclear cardiology
- Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
- Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source
- Attenuation correction using asymmetric fanbeam transmission CT on two-head SPECT system
- 31 Ga-67イメージングにおける散乱線補正に関する検討(核医学検査 レジストレーション・他,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- 補正組み込み型OS-EM法の再構成条件が左室内腔容積算出に及ぼす影響
- Tl-201腫瘍 Scintigraphy における off-peak Window の有用性 : Phantom 実験による検討(核医学検査 SPECT収集, 一般研究発表予稿集, 日本放射線技術学会第33回秋季学術大会)
- 減弱(吸収)補正 : TCT法を中心に(第45回核医学分科会プログラム)
- 経時的造影ハーモニックイメージガイド脈内エタノール注入療法 : Dynamic PEIT
- SPECT/CTにおける画像補正法
- SPECT/CTの役割
- PET/CT時代における骨、^Tl, ^Gaシンチの意義 : 司会の言葉
- 核医学装置の動向
- SPECT/CT融合画像の臨床応用(第51回核医学分科会)
- 心筋SPECT
- Azelnidipine, a long-acting calcium channel blocker, could control hypertension without decreasing cerebral blood flow in post-ischemic stroke patients. A ^I-IMP SPECT follow-up study
- Management of sentinel lymph nodes in malignant skin tumors using dynamic lymphoscintigraphy and the single-photon-emission computed tomography/computed tomography combined system
- Development of a collimator blurring compensation method using fine angular sampling projection data in SPECT
- Optimum energy window setting on Hg-201 x-rays photopeak for effective Tl-201 imaging
- Accurate scatter correction for transmission computed tomography using an uncollimated line array source
- 45.当科における肺野小型末梢異常陰影に対する最近の胸腔鏡下手術の検討(一般演題)(第24回 日本気管支学会九州支部総会)
- Hyperoxia-induced Acute Lung Injury Using a Pig Model: Correlation between MR Imaging and Histologic Results
- Phantom Evaluation of Scatter and Attenuation Correction in Thallium-201/Technetium-99m Acquisition in Myocardial Perfusion Single-photon Emission Computed Tomography
- Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source thallium-201 myocardial SPECT
- Evaluation of persistence of ductus venosus with Tc-99m DTPA galactosyl human serum albumin liver scintigraphy and I-123 iodoamphetamine per-rectal portal scintigraphy
- 44.肺末梢性カルチノイド腫瘍の1例 : 第39回日本肺癌学会九州支部会
- A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123
- B-72. Diagnostic Value of the Thalamic Veins
- 18.Screlosing hemangiomaの1例 : 第38回日本肺癌学会九州支部会
- 呼吸停止下心電図同期 black-blood 法による心臓の高速 MR imaging
- 第37回日本肺癌学会九州支部会 : 1.Bronchioloalveolar carcinomaのCT,MRI所見
- ^Tl心筋SPECTにおける transmission 法による減弱補正
- Differential Diagnosis of Small Round Cervical Lymph Nodes: Comparison of Power Doppler US with Contrast-enhanced CT and Pathologic Results
- PJ-231 Plasma Brain Natriuretic Peptide is a Novel Predictive Factor of Carotid Atherosclerosis in Patients with Hypertension(Atherosclerosis,clinical(10)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society
- PJ-308 Plasma Heparin Cofactor II Activity is Associated with Plaque Vulnerability in Patients with Stable Angina Pectoris(Atherosclerosis, clinical-10, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- EFFECTS OF PROPRANOLOL AND NIFEDIPINE ON EXERCISE-INDUCED ATTACK IN PATIENTS WITH VARIANT ANGINA : ASSESSMENT BY EXERCISE T1-201 ECT USING BULL'S-EYE METHOD : Ischemic Heart Disease : PROCEEDINGS OF THE 50th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCU
- ^Tl SPECTにおける散乱線補正に関する研究
- Sequential Changes in Ischemic Edema Following Transient Focal Cerebral Ischemia in Rats: Magnetic Resonance Imaging Study
- MR Imaging of the Anterior Cruciate Ligament: Value of Thin Slice Direct Oblique Coronal Technique
- Correlation of ^Tc-GSA Hepatic Scintigraphy with Liver Biopsies in Patients with Chronic Active Hepatitis Type C
- Small Cell Carcinoma of the Stomach: A case Report
- Percutaneous Microwave Coagulation Therapy: An Experimental Study
- 第32回日本肺癌学会九州支部会 : 6.肺野小型病変に対するThin-slice CT診断能
- Metastatic Liver Tumor from Cystic Ovarian Carcinomas:CT and MRI Appearance
- Improvement of image quality using interpolated projection data estimation method in SPECT
- The Value of Fast and Ultrafast T2-weighted MR Imaging Sequences in Hepatic Enhancement with Ferumoxides:Comparison with Conventional Spin-echo Sequence
- Calculation of T2 Relaxation Time from Ultrafast Single Shot Sequences for Differentiation of Liver Tumors:Comparison of Echo-planar, HASTE, and Spin-echo Sequences
- ^TlイメージングでのTEW法による散乱線補正のためのエネルギーウィンドウ設定に関する基礎的検討
- ^Tlイメージングにおけるoff-peak triple energy window 収集による散乱線補正
- ^Tl イメージングのための ^Hg 特性X線ピーク領域におけるエネルギースペクトル解析
- Determination of overall perturbation factors for plane-parallel ionization chambers in electron beams
- Determination of overall perturbation factors for parallel-plate ionization chambers in electron beams
- Totally Occluded Iliac Arteries: Long-term Results of Pecutaneous Transluminal Angioplasty
- Determination of the Optimal Pulses in MR Imaging with Magnetization Transfer Contrast at 7 Tesla
- Value of Magnetization Transfer Contrast in Intracranial Enhancing and Nonenhancing Lesions with Paramagnetic Contrast Agents
- PREPARATION AND EVALUATION OF W/O TYPE AND W/O/W TYPE EMULSIONS CONTAINING AN ANTICANCER DRUG
- 異型狭心症発作時^Tl心筋シンチグラムにおける不完全再分布像の検討 : ポスター発表 : 第57回日本循環器学会学術集会
- Measurement of Effective Renal Plasma Flow (ERPF) with 123I - Orthoiodohippurate (I - 123 - OIH)
- Quantitative evaluation of the regional hepatic reserve by ^Tc-GSA dynamic SPECT before and after chemolipiodolization in patients with hepatocellular carcinoma
- Azelastine : Its Clinical Application for Radiation Dermatitis
- External Radiation Therapy of Prostatic Carcinoma and Its Relationship to Hormonal Therapy
- Quantitative renography with the organ volume method and interporative background subtraction technique
- 心筋 SPECT における半側臥位撮像法の検討
- Transjugular Intrahepatic Portosystemic Shunt: Initial Clinical Experience and Three-Year Follow-up
- Functional Evaluation of Transplanted Kidneys by Gd-DTPA Enhanced Turbo FLASH MR Imaging
- 核医学装置の動向 (特集 核医学装置の現状と将来)
- MRA
- MR Imaging of Lingual Carcinoma : Comparison with Surgical Staging
- Estimation of 123I-IMP arterial blood activity from dynamic planar imaging of the chest using a graph plot method for the quantification of regional cerebral blood flow
- Intraarterial Catheter Thrombolytic Therapy for Acute Peripheral Arterial Occlusions
- Carbon-13 Magnetic Resonance Spctroscopy of Glucose Metabolism in SCC-VII Tumors
- Clinical usefulness of a collimator distance dependent resolution recovery in myocardial perfusion SPECT : a clinical report from a single institute
- Secretion of Human Atrial Natriuretic Peptide in Response to Atrial Pacing and Its Function in Patients with Ventricular Septal Defect
- Improvement of the ^Tc-ECD brain uptake ratio (BUR) method for measurement of cerebral blood flow
- FDG-PET/CT-based Gross Tumor Volume Contouring for Radiation Therapy Planning: An Experimental Phantom Study