補正組み込み型OS-EM法の再構成条件が左室内腔容積算出に及ぼす影響
スポンサーリンク
概要
- 論文の詳細を見る
The aim of this study was to evaluate the effect of reconstruction parameters on the measurement of global left ventricular (LV) volume and define the appropriate reconstruction parameters when using the ordered subsets expectation maximization (OS-EM) method and 3D OS-EM (AstonishTM) method including the collimator distance response (CDR) recovery (RC) for myocardial perfusion SPECT study. Method: An anthropomorphic torso phantom with a 56 ml LV part was used. The LV volume was calculated with QPS software by the Update number (iteration number×subsets number) of OS-EM and 3D OS-EM (AstonishTM). Results and Conclusion: LV volumes calculated with OS-EM and AstonishTM without attenuation and scatter corrections corresponded to the true obtained by the Update number about 32 times and 24 times when using the OS-EM and AstonishTM method with attenuation and scatter corrections, respectively. However, LV volumes have changed greatly in the AstonishTM method according to the change in the Update number. Appropriate numbers of iterations and subsets are the measurement of global LV volumes, especially when using the OS-EM algorithm with RC.
- 2009-07-20
著者
-
中村 祐也
熊本大学大学院保健学教育部
-
冨口 静二
熊本大学医学部保健学科
-
勝田 昇
熊本大学医学部附属病院医療技術部
-
冨口 静二
熊本大学放射線科
-
冨口 静二
熊本大学医学部 保健学科
-
冨口 静二
熊本大学医学部附属病院 放射線科
-
冨口 静二
熊本大学 大学院医学薬学研究部放射線診断学部門
-
Katsuda Noboru
Department Of Radiology Kumamoto University School Of Medicine
-
鷹本 慶子
日立メディコアプリケーション部
-
冨口 静二
熊本大学 医学部神経内科
-
Tomiguchi Seiji
Department Of Radiology Kumamoto University School Of Medicine
-
Tomiguchi Seiji
Department Of Radilogy Kumamoto University School Of Medicine
-
勝田 昇
熊本大学医学部附属病院中央放射線部
関連論文
- 屋内ラドンの高濃度化の要因調査 : 熊本市の場合
- 心筋SPECT検査におけるcollimator detector response(CDR)補正とeffective scatter source estimation(ESSE)法による散乱線補正の有用性
- 196. 国内の施設における増感紙-フィルム系の MTF の測定精度の比較 (第 2 報)(第 46 回総会学術大会会員研究発表予稿)
- 胸部病室撮影のための新しいグリッドの評価 : ミスアライメントの効果について
- 胸部ポータブル撮影時における平行孔グリッドの評価
- 4)CR画像の撮影実態(ディジタルX線画像の画質と被曝)
- 多施設共同ファントム実験による ^Tc SPECT の散乱・吸収補正の定量性評価
- SPECT定量ワーキンググループ成果報告
- 218.2重IPカセッテの開発と物理特性の計測
- わが国で使用されている増感紙-フィルム系の感度特性 : 絶対感度測定の重要性
- 384. 新しい増感紙-フィルム系の物理特性と臨床応用(画像工学 新オルソシステム-2)
- 101. 増感紙-フィルム系の画質特性(画像工学 画質計測)
- 13. 増感紙-フィルム系の画質特性(九州部会)
- 183. 増感紙-フィルム系の画質特性(第 21 回秋季学術大会一般研究発表予稿)
- ^Tl 心筋 SPECT におけるトランスミッション・エミッションデータ同時収集法の評価
- 19.胸部単純撮影で検出し得なかった肺高分化型腺癌の2例(第35回日本肺癌学会九州支部会)
- エネルギースペクトルとイメージによる二核種同時収集における crosstalk 率の測定
- 加齢, 喫煙が肺に及ぼす影響 -^I-IMP dynamic scintigraphy による検討 -
- 定量的な放射性タリウムイメージングのためのコリメータ選択
- 虚血性心疾患における^Tc-tetrofosmin (PPN 1011) 心筋 SPECT の検討
- 5. CTガイド下肺生検の検討(第33回 日本肺癌学会九州支部会)
- 胃憩室の検討
- 最近2年間の間接胃集検フィルムの示現能・読影能
- 高濃度バリウム(180W/V%)の胃集検への使用試み
- 頭頸部腫瘍の放射線治療効果判定におけるT1-201 SPECTの有用性について
- 70. asymmetric system の基礎的特性と臨床応用(画像技術-1 非対称システム)
- 東芝製 TO タイプ増感紙の画像特性
- 乳房撮影における両面増感紙 : 両面乳剤フィルム系の画像特性と微小石灰化の検出能
- 診断領域における増感紙-フィルム系の物理特性の計測と解析
- 8. パソコンによる MEVATORON (3 MV) のコントロールシステムの開発(治療, 九州部会)
- 447. 乳房微小石灰化の検出能における増感紙-フィルム系の比較(画像理論-6 主観評価)
- 424. 胸部撮影用感度補償増感紙の試作(II) : 感度補償増感紙 : 第43回総会会員研究発表予稿
- 363. 胸部ポータブル撮影における低格子グリッドの評価
- 362. 胸部ポータブル撮影用平行孔グリッドの評価
- PS-096-4 CT/SPECT combined systemによるsentinel lymph nodeの3次元的Navigation
- 低線量ラセンCTによる肺癌検診にて発見された肺葉内肺分画症の一例
- Role of cardiac computed tomography in patients with suspected coronary artery disease : interaction with nuclear cardiology
- Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
- Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source
- Attenuation correction using asymmetric fanbeam transmission CT on two-head SPECT system
- 補正組み込み型OS-EM法の再構成条件が左室内腔容積算出に及ぼす影響
- 減弱(吸収)補正 : TCT法を中心に(第45回核医学分科会プログラム)
- SPECT/CTにおける画像補正法
- SPECT/CTの役割
- PET/CT時代における骨、^Tl, ^Gaシンチの意義 : 司会の言葉
- 核医学装置の動向
- 核医学装置の現状と将来 : 司会の言葉
- SPECT/CT融合画像の臨床応用(第51回核医学分科会)
- 255 CRシステムにおける胸部撮影線量の調査
- 209. CR (Computed Radiography) における撮影線量の検討 (第 2 報)(放射線管理 被曝線量・測定器)
- 14. CR (Computed Rediography) における撮影線量の検討(九州部会)
- 増感紙の発光量と相対感度に関する研究
- 心筋SPECT
- 23.Resetable Counterの試作報告(PUCK用)(◇九州部会◇)
- 197.断層軌道評価への知覚系の導入 : 1)内耳断層への適用(第37回総会会員研究発表)(撮影理論-5)
- 192.断層軌道評価への知覚系の導入(II) : 視神経管断層への適用(第37回総会会員研究発表)(撮影理論-5)
- Management of sentinel lymph nodes in malignant skin tumors using dynamic lymphoscintigraphy and the single-photon-emission computed tomography/computed tomography combined system
- Development of a collimator blurring compensation method using fine angular sampling projection data in SPECT
- Optimum energy window setting on Hg-201 x-rays photopeak for effective Tl-201 imaging
- Accurate scatter correction for transmission computed tomography using an uncollimated line array source
- 45.当科における肺野小型末梢異常陰影に対する最近の胸腔鏡下手術の検討(一般演題)(第24回 日本気管支学会九州支部総会)
- Hyperoxia-induced Acute Lung Injury Using a Pig Model: Correlation between MR Imaging and Histologic Results
- Phantom Evaluation of Scatter and Attenuation Correction in Thallium-201/Technetium-99m Acquisition in Myocardial Perfusion Single-photon Emission Computed Tomography
- Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source thallium-201 myocardial SPECT
- Evaluation of persistence of ductus venosus with Tc-99m DTPA galactosyl human serum albumin liver scintigraphy and I-123 iodoamphetamine per-rectal portal scintigraphy
- 44.肺末梢性カルチノイド腫瘍の1例 : 第39回日本肺癌学会九州支部会
- A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123
- 270. C-Dダイアグラムによる4種類のDSA装置の比較 : DSA装置
- 269. CRとDFにおける模擬血管の検出能の比較 : DSA装置
- 268. DSA装置の特性曲線の比較 : DSA装置
- 21. ステレオDSAにおける血管間隔の識別能について : 画像理論
- 54. DSAにおける立体撮影の深さの識別能について : 九州部会 : デジタル画像(1)
- 18.Screlosing hemangiomaの1例 : 第38回日本肺癌学会九州支部会
- 呼吸停止下心電図同期 black-blood 法による心臓の高速 MR imaging
- 第37回日本肺癌学会九州支部会 : 1.Bronchioloalveolar carcinomaのCT,MRI所見
- ^Tl心筋SPECTにおける transmission 法による減弱補正
- 496. MRangiography : コンピュータシミュレーションによる血流信号表示の試み(MR-13 MRA-3 流速測定)
- 43. MR angiography における血管描出のコンピュータシミュレーション(MR-2, 九州部会)
- 496. MR angiography : コンピュータシミュレーションによる血流信号表示の試み(第 47 回総会学術大会一般研究発表予稿)
- 9.デジタルTV断層の基本的検討(II)
- 診断領域におけるカーボンGRID特性の測定 : 第44回総会学術研究発表抄録 : グリッド他
- ^Tl SPECTにおける散乱線補正に関する研究
- 胸部撮影のための新しい増感紙 : フィルム系の臨床評価
- 胸部撮影のための新しい増感紙-フィルム系の画像特性
- 画像工学 新感材システム-2
- 第32回日本肺癌学会九州支部会 : 6.肺野小型病変に対するThin-slice CT診断能
- 53. CTダイアグラムによる4種類のDAS装置の比較 : 九州部会 : デジタル画像(1)
- マルチフォーマットカメラのコントラストの調整がDSA画像の検出能におよぼす影響について : イメージングカメラ
- DSA装置の識閾コントラストの比較
- 10.マルチフォーマットカメラのコントラストの調整がDSA画像の検出能におよぼす影響について
- ^TlイメージングでのTEW法による散乱線補正のためのエネルギーウィンドウ設定に関する基礎的検討
- ^Tlイメージングにおけるoff-peak triple energy window 収集による散乱線補正
- ^Tl イメージングのための ^Hg 特性X線ピーク領域におけるエネルギースペクトル解析
- Asymmetric Screen-Film System の画像特性と臨床評価
- 異型狭心症発作時^Tl心筋シンチグラムにおける不完全再分布像の検討 : ポスター発表 : 第57回日本循環器学会学術集会
- 心筋 SPECT における半側臥位撮像法の検討
- 核医学装置の動向 (特集 核医学装置の現状と将来)
- 心筋SPECT検査における collimator detector response (CDR) 補正と effective scatter source estimation(ESSE) 法による散乱線補正の有用性
- センチネルリンパ節生検における dynamic RI とCT/SPECTの意義
- 多施設による ^Tc-MAG_3 腎機能定量解析精度の検討