A New 4.PI..BETA. Counter Operated at Atmospheric Pressure of CF4 Gas for the Computer Discrimination Method.
スポンサーリンク
概要
- 論文の詳細を見る
4πβ-γ coincidence counting using a 4πβ pressurized proportional counter combined with the computer discrimination method has made it possible to determine the disintegration rate precisely and rapidly. Recently, measurement of short half-life nuclide requires further shortening of the gas replacement time, and we proposed to use atmospheric CF<SUB>4</SUB> gas instead of pressurized Ar 90%-CH<SUB>4</SUB> 10% mixture. However, a conventional 4πβ counter with CF<SUB>4</SUB> gas at atmospheric pressure gave unsatisfactory results ; small slopes of coincidence efficiency functions and low detection efficiencies for electron-capture decay nuclides. In order to resolve these problems, we constructed a new 4πβ counter with large volume and multianodes. Good plateau characteristics and good time relation between β and γ pulses were obtained in spite of large volume, and the slopes of coincidence efficiency functions and the detection efficiencies were improved. Use of this counter made it possible to measure short half-life nuclides and also easy to measure usual nuclides.
- 一般社団法人 日本原子力学会の論文
著者
-
Miyahara Hiroshi
Department Of Intelligent Machinery And Systems Kyushu University
-
Mori Chizuo
Department Of Electricity Aichi Institute Of Technology
-
Noguchi Takuya
Department of Chemistry, The University of Tokyo, Tokyo 113-0033, Japan
-
MORI Chizuo
Department of Nuclear Engineering, School of Engineering, Nagoya University
-
MATUMOTO Hiroki
Department of Nuclear Engineering, School of Engineering, Nagoya University
-
MIYAHARA Hiroshi
Department of Nuclear Engineering, School of Engineering, Nagoya University
関連論文
- Production of ^Eu for Gamma-Ray Emission Probability Measurement
- Development of Two-dimensional Data-acquisition Apparatus Using 8 mm Data Cartridge for 4πβ-γ Coincidence Measurement
- Highly Precise Measurement of the Relative Gamma-ray Detection Efficiency Curve
- Overturning of Molecules in Built-Up Iron Stearate MML Examined by ^Fe-Tracer Technique
- A Range Measurement of Low Energy Electrons Using Radioisotope Auger Electrons
- A Long and Slender Position-Sensitive Helium-3 Proportional Counter with an Anode Wire Supported by a Ladder-Shaped Solid Insulator
- Mean Free Path for Plasmon Excitation in Aluminum in the Energy Region from 1.5 to 10.9 keV
- Electron Stopping Power in Aluminum in te Energy Region from 2 to 10.9 keV
- Application of Digital Waveform Processing to Position-Sensitive Proportional Counter
- Precise Measurement of Gamma-Ray Emission Probabilities for ^W by Using a Two-Dimensional 4πβ-γCoincidence System
- Regioselective Acetylation of 2-Aryl-2-butene-1,4-diols and Hydrolysis of Their Diacetates Using Porcine Pancreas Lipase
- Characteristics and Correction of the Fading of Imaging Plate
- Precise Measurement of the Gamma-ray Emission Probabilities for ^In with Half-life of 54. 15 min
- Disintegration rate measurement of ^Pr
- GM-18 CONSOLIDATION OF SURFACE LAYER OF P/M GEARS BY FINISH ROLLING WITH SCREW-SHAPED TOOL(GEAR MANUFACTURING)
- Photoelectric Emission of Metals by X-Rays in the KeV Region
- Development of Thread Rolled Anti-Loosening Bolts Based on the Double Thread Mechanism and a Performance Evaluation(Recent Advances in Materials and Processing (I))
- Magnetotransport Properties of Fe/Pentacene/Co:TiO2 Junctions with Fe Top Contact Electrodes Prepared by Thermal Evaporation and Pulsed Laser Deposition
- Niobium(V) Chloride Catalyzed Oxidation of Dithioacetals with 30% Hydrogen Peroxide: A Concise Preparation of Bissulfonylmethylene Compounds
- Use of carbon fiber as resistive anode wire for position sensitive proportional counter.
- Position sensitive proportional counter for measurement of tritium labelled gas movement.
- Dependence of position signal on pulse height and gas gain for 3H .BETA.-rays observed with position sensitive proportional counter.
- A New 4.PI..BETA. Counter Operated at Atmospheric Pressure of CF4 Gas for the Computer Discrimination Method.
- Precise Measurement of Gamma-Ray Emission Probability for Germanium-75.
- Dependence of Position Signal on Pressure of Counting Gas in Charge Division Type Position-Sensitive Proportional Counter.
- Simple and Quick Measurement of Neutron Flux Distribution by Using an Optical Fiber with Scintillator.