Commercially available carbon fiber was used as a new resistive anode wire for a charge division type position sensitive proportional counter. It has a small diameter of 7 μm and a large electrical resistance of about 4 kΩ/cm and is available at a very low cost. Although about 3, 000 fibers are weakly sticked together in a bundle with a kind of adhesives, a single fiber can easily be taken out from the bundle after the dissolution of the adhesives by acetone. Because of the smaller diameter compared with conventional anode wires, the lower high voltage serves the purpose. However, in the same reason, the saturation of gas multiplication appeared and hence an energy linearity tended to be lost, which was not much trouble for position detectors. Electrical resistance was uniform throughout all the length, which resulted in a small standard deviation of ±0.35% in the position linearity for a length of 20 cm. The relative position resolution for collimated Mn KX-rays was 0.47% in FWHM.
- 一般社団法人 日本原子力学会の論文
著者
-
Aoyama Takahiko
Department Of Cardiac Surgery Aichi Medical University
-
Watanabe Tamaki
Department Of Nuclear Engineering Faculty Of Engineering Nagoya University
-
Mori Chizuo
Department Of Electricity Aichi Institute Of Technology
-
MORI Chizuo
Department of Nuclear Engineering, Faculty of Engineering, Nagoya University
関連論文
- Pharmacokinetic/Pharmacodynamic Modeling and Simulation of Rosuvastatin Using an Extension of the Indirect Response Model by Incorporating a Circadian Rhythm
- Highly Precise Measurement of the Relative Gamma-ray Detection Efficiency Curve
- Overturning of Molecules in Built-Up Iron Stearate MML Examined by ^Fe-Tracer Technique
- A Range Measurement of Low Energy Electrons Using Radioisotope Auger Electrons
- A Long and Slender Position-Sensitive Helium-3 Proportional Counter with an Anode Wire Supported by a Ladder-Shaped Solid Insulator
- Mean Free Path for Plasmon Excitation in Aluminum in the Energy Region from 1.5 to 10.9 keV
- Electron Stopping Power in Aluminum in te Energy Region from 2 to 10.9 keV
- Pharmacokinetics/Pharmacodynamics of Acetaminophen Analgesia in Japanese Patients with Chronic Pain(Biopharmacy)
- PJ-540 Risk of Surgery after Coronary Drug-Eluting Stent Implantation(PJ091,Coronary Revascularization, PCI (DES) 3 (IHD),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- OJ-365 Comparison of Percutaneous Coronary Intervention (PCI), Medical Therapy (MED) and coronary bypass grafts (CABG) on Small Vessel Disease : A Matched Comparison by Quantitative Coronary Angiography (QCA)(Coronary Revascularization, PTCA/Stent/DCA/Rot
- Pharmacokinetic Modeling and Prediction of Plasma Pyrrole-Imidazole Polyamide Concentration in Rats Using Simultaneous Urinary and Biliary Excretion Data
- Application of Digital Waveform Processing to Position-Sensitive Proportional Counter
- Paroxysmal Atrial Fibrillation due to Bronchogenic Cyst
- Usefulness of a Method for Changing Tube Current during Helical Scanning in Multislice CT
- Pharmacokinetics of Fluconazole and Fosfluconazole after Intraperitoneal Administration to Peritoneal Dialysis Rats
- EVALUATION OF INTRAVASCULAR HEMOLYSIS BY HAPTOGLOBIN ADMINISTRATION AFTER PROSTHETIC VALVE REPLACEMENT
- ASSESSMENT OF DONOR HEART FUNCTION IMMEDIATELY AFTER HETEROTOPIC CARDIAC TRANSPLANTATION : Ventricular Function : 53 Annual Scientific Meeting, Japanese Circulation Society
- Precise Measurement of Gamma-Ray Emission Probabilities for ^W by Using a Two-Dimensional 4πβ-γCoincidence System
- LONG-TERM PROGNOSIS OF PATIENTS WITH CONGESTIVE HEART FAILURE : 51st Annual Meeting of the Japanese Circulation Society
- -P38-QUANTITATIVE EVALUATION OF SIMULTANEOUS DUAL SINGLE PHOTON EMISSION COMPUTED TOMOGRAFHY IN THE SITES OF ACUTE MYOCARDIAL INFARCTION : COMPARATIVE STUDY WITH MAGNETIC RESONANCE IMAGES (MRI) : RI : FREE COMMUNICATIONS(III) : PROCEEDINGS OF THE 53th ANN
- -549- CARDIOVASCULAR EFFECTS OF CIGARETTE SMOKING ON EXERCISE IN PATIENTS WITH CORONARY ARTERY DISEASE
- Residual Cardiomyocytes and Scintigraphic Findings in Advanced Coronary Artery Disease : Correlation with Technetium-99m-Tetrofosmin and Thallium-201 Single Photon Emission Computed Tomography
- 0979 QUANTITATIVE RESTING TECHNETIUM-99m-TETROFOSMIN IMAGING IN PREDICTING FUNCTIONAL RECOVERY AFTER REVASCULARIZATION : COMPARISON WITH REST-REDISTRIBUTION THALLIUM-201
- -0386- IMPAIRED MYOCARDIAL FATTY ACID UTILIZATION IN PATIENTS WITH EFFORT ANGINA(PROCEEDINGS OF THE 59th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY)
- -0122- IMAPAIRED FATTY ACID UPTAKE IN RELATION TO WALL MOTION ABNORMALITY IN ISCHEMIC BUT VIABLE MYOCARDIUM IDENTIFIED BY THALLIUM-201 REINJECTION(PROCEEDINGS OF THE 59th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY)
- Characteristics and Correction of the Fading of Imaging Plate
- Precise Measurement of the Gamma-ray Emission Probabilities for ^In with Half-life of 54. 15 min
- Primary Liposarcoma of the Mediastinum
- Tamponade After Open-Heart Surgery With Percutaneous Cardiopulmonary Support
- Optimization and validation of a high-performance liquid chromatographic method with UV detection for the determination of pyrrole-imidazole polyamides in rat plasma
- Successfully Treated Infected Left Ventricular Pseudoaneurysm after the Dor Operation
- Determination of pyrrole-imidazole polyamide in rat plasma by liquid chromatography-tandem mass spectrometry
- Photoelectric Emission of Metals by X-Rays in the KeV Region
- Emergent thoracic aortic angioplasty and stenting for middle aortic syndrome in non-specific aortitis
- Use of carbon fiber as resistive anode wire for position sensitive proportional counter.
- Position sensitive proportional counter for measurement of tritium labelled gas movement.
- Dependence of position signal on pulse height and gas gain for 3H .BETA.-rays observed with position sensitive proportional counter.
- A New 4.PI..BETA. Counter Operated at Atmospheric Pressure of CF4 Gas for the Computer Discrimination Method.
- Precise Measurement of Gamma-Ray Emission Probability for Germanium-75.
- Dependence of Position Signal on Pressure of Counting Gas in Charge Division Type Position-Sensitive Proportional Counter.
- Simple and Quick Measurement of Neutron Flux Distribution by Using an Optical Fiber with Scintillator.