Use of carbon fiber as resistive anode wire for position sensitive proportional counter.
スポンサーリンク
概要
- 論文の詳細を見る
Commercially available carbon fiber was used as a new resistive anode wire for a charge division type position sensitive proportional counter. It has a small diameter of 7 μm and a large electrical resistance of about 4 kΩ/cm and is available at a very low cost. Although about 3, 000 fibers are weakly sticked together in a bundle with a kind of adhesives, a single fiber can easily be taken out from the bundle after the dissolution of the adhesives by acetone. Because of the smaller diameter compared with conventional anode wires, the lower high voltage serves the purpose. However, in the same reason, the saturation of gas multiplication appeared and hence an energy linearity tended to be lost, which was not much trouble for position detectors. Electrical resistance was uniform throughout all the length, which resulted in a small standard deviation of ±0.35% in the position linearity for a length of 20 cm. The relative position resolution for collimated Mn KX-rays was 0.47% in FWHM.
- 一般社団法人 日本原子力学会の論文
著者
-
Aoyama Takahiko
Department Of Cardiac Surgery Aichi Medical University
-
Watanabe Tamaki
Department Of Nuclear Engineering Faculty Of Engineering Nagoya University
-
Mori Chizuo
Department Of Electricity Aichi Institute Of Technology
-
MORI Chizuo
Department of Nuclear Engineering, Faculty of Engineering, Nagoya University
関連論文
- Pharmacokinetic/Pharmacodynamic Modeling and Simulation of Rosuvastatin Using an Extension of the Indirect Response Model by Incorporating a Circadian Rhythm
- Highly Precise Measurement of the Relative Gamma-ray Detection Efficiency Curve
- Overturning of Molecules in Built-Up Iron Stearate MML Examined by ^Fe-Tracer Technique
- A Range Measurement of Low Energy Electrons Using Radioisotope Auger Electrons
- A Long and Slender Position-Sensitive Helium-3 Proportional Counter with an Anode Wire Supported by a Ladder-Shaped Solid Insulator
- Mean Free Path for Plasmon Excitation in Aluminum in the Energy Region from 1.5 to 10.9 keV
- Electron Stopping Power in Aluminum in te Energy Region from 2 to 10.9 keV
- Pharmacokinetics/Pharmacodynamics of Acetaminophen Analgesia in Japanese Patients with Chronic Pain(Biopharmacy)
- PJ-540 Risk of Surgery after Coronary Drug-Eluting Stent Implantation(PJ091,Coronary Revascularization, PCI (DES) 3 (IHD),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- OJ-365 Comparison of Percutaneous Coronary Intervention (PCI), Medical Therapy (MED) and coronary bypass grafts (CABG) on Small Vessel Disease : A Matched Comparison by Quantitative Coronary Angiography (QCA)(Coronary Revascularization, PTCA/Stent/DCA/Rot