Dependence of position signal on pulse height and gas gain for 3H .BETA.-rays observed with position sensitive proportional counter.
スポンサーリンク
概要
- 論文の詳細を見る
Position information obtained with a charge division type position sensitive proportional counter for <SUP>3</SUP>H β-rays emitted from a point source depends on the pulse height and the gas gain, because the gas gain for each β-ray is influenced by the direction of its track with respect to the anode wire. With the increase of the gas gain, position signals of pulses with large pulse height appear first in a single broad position, and then in two different positions. The reason is that the gas gain for β-rays making the tracks perpendicular to the anode wire is smaller than that for those parallel to the wire owing to self-induced space charge effect at large gas gain. Consequently, the parallel tracks give the largest pulse height of all. When isobutane is used as counting gas, with the further increase of the gas gain position signals of pulses with large pulse height appear in three different positions and finally in a single position. The final phenomenon in isobutane means that the gas gain for β-rays making the tracks perpendicular to the anode wire is the largest of all at this gas gain.
- 一般社団法人 日本原子力学会の論文
著者
-
Watanabe Tamaki
Department Of Nuclear Engineering Faculty Of Engineering Nagoya University
-
Mori Chizuo
Department Of Electricity Aichi Institute Of Technology
関連論文
- Highly Precise Measurement of the Relative Gamma-ray Detection Efficiency Curve
- Overturning of Molecules in Built-Up Iron Stearate MML Examined by ^Fe-Tracer Technique
- A Range Measurement of Low Energy Electrons Using Radioisotope Auger Electrons
- A Long and Slender Position-Sensitive Helium-3 Proportional Counter with an Anode Wire Supported by a Ladder-Shaped Solid Insulator
- Mean Free Path for Plasmon Excitation in Aluminum in the Energy Region from 1.5 to 10.9 keV
- Electron Stopping Power in Aluminum in te Energy Region from 2 to 10.9 keV
- Application of Digital Waveform Processing to Position-Sensitive Proportional Counter
- Precise Measurement of Gamma-Ray Emission Probabilities for ^W by Using a Two-Dimensional 4πβ-γCoincidence System
- Characteristics and Correction of the Fading of Imaging Plate
- Precise Measurement of the Gamma-ray Emission Probabilities for ^In with Half-life of 54. 15 min
- Photoelectric Emission of Metals by X-Rays in the KeV Region
- Use of carbon fiber as resistive anode wire for position sensitive proportional counter.
- Position sensitive proportional counter for measurement of tritium labelled gas movement.
- Dependence of position signal on pulse height and gas gain for 3H .BETA.-rays observed with position sensitive proportional counter.
- A New 4.PI..BETA. Counter Operated at Atmospheric Pressure of CF4 Gas for the Computer Discrimination Method.
- Precise Measurement of Gamma-Ray Emission Probability for Germanium-75.
- Dependence of Position Signal on Pressure of Counting Gas in Charge Division Type Position-Sensitive Proportional Counter.
- Simple and Quick Measurement of Neutron Flux Distribution by Using an Optical Fiber with Scintillator.