Activity Measurement of Plutonium in Solid Samples by LX-ray Counting with a Phoswich Detector.
スポンサーリンク
概要
- 論文の詳細を見る
By using a NaI(Tl)/CsI(Tl) phoswich detector we have developed a method to measure radioactivity of Pu in various types of solid samples. The minimum detectable radioactivity for 33% error was proved to be 0.64Bq for 1h counting and 0.11Bq for 24h counting. This method can save plenty of time for sample preparation and can preserve the condition of the sample for other research purposes. This method also ensures radiation safety, because the sample can easily be sealed. In biological studies of inhalation toxicology of Pu, we are using this method for activity measurement of solid samples such as air sampling filters, elements of cascade impactor or animal tissues.
著者
関連論文
- Estimation of Organ Dose in the Rat Exposed to X-rays for Radiobiological Study by TLD Implantation Method
- 討論会「ICRP 2005 年新勧告の論点」を開催して
- ICRP新呼吸気道モデルのラドンへの適用
- 固体飛跡検出器CR-39におけるAgingとFadingの影響
- IAEA調整研究プログラム「放射性核種摂取評価における相互比較と体内動態モデルの有効性」に関する研究調整会議
- 原子間力顕微鏡による微小核飛跡の解析
- ICRP新呼吸気道モデルに基づく^Puの内部被曝線量評価における粒子性状依存性
- α放射体のマクロオ-トラジオグラフィにおける固体飛跡検出器TS-16Nの撮像媒体としての特性〔英文〕
- 1.29MeVから5.48MeVのα粒子に対するCR-39プラスチックのエッチピット径のエネルギ-依存性〔英文〕
- TLDバックグランドの窒素ガスフロ-による低減化効果の評価〔英文〕
- 簡易型較正用α線照射容器〔英文〕
- ICRPの内部被ばく線量評価モデルに基づく^Puのモニタリング量の計算
- 5. 生物学的安全性評価研究におけるプルトニウムの線量評価
- ^Pu の吸入被ばくにおける線量の人体特性パラメータによる変動の試算
- Lung Retention of Pu Following Inhalation of PuO2 in Rats Measured Using a Whole Body Counter
- A Device for In Vitro Irradiation with α-Particles Using an (α-Emitting Radioactive Source
- Effects of DTPA Therapy on Removal of Inhaled High-fired Plutonium Oxide in Rats
- 原子間力顕微鏡による粒子線飛跡の微小エッチピットの解析法
- TB-1-1 放射線防護におけるファントム
- 放射線防護における人体ファントム
- Effect of Polymeric Plutonium on the Hematopoietic Activity in the Bone Marrow of Mice
- Activity Measurement of Plutonium in Solid Samples by LX-ray Counting with a Phoswich Detector.
- Characteristics of Plutonium Oxide Aerosol Particles Generated by Nebulization.
- Assessment of Initial Alveolar Deposition on Rats Exposed to Plutonium Aerosols Using a Whole Body Counter.
- Application of the TV device manufactured for image analyzation to the measurement of etch pit diameter.
- Batch variations of CR-39 plastic track detector in .ALPHA.-track registration properties.
- Evaluation of background in CR-39 detector for .ALPHA.-particle detection.
- Bulk-etch rate of CR-39 detector under various conditions of temperature and concentration of NaOH solution.