Application of the TV device manufactured for image analyzation to the measurement of etch pit diameter.
スポンサーリンク
概要
- 論文の詳細を見る
The diameter of mouth of etched nuclear track has generally been measured for the purposes of examining the properties of the incident particle, obtaining the registration characteristics of the track detector and also checking the qualities of both the etching procedures and the detector itself. For increasing the efficiency of the diameter measurement, the application of an automated TV device manufactured for image analyzation was examined for the etch pits of α-particles on CR-39 plastic track detector; a comparison with precise microphotographic method was carried out. It has been confirmed that the mean value of the diameters could be determined with a sufficient accuracy and reproducibility, if the threshold level of the darkness for the etch pit image was appropriately set. It should be noted, however, that the standard deviation of the distribution of etch pit diameters was overestimated by the magnification of 1.3-1.4, which was attributed to the fluctuation of the measured values from position to position in a single visual field.
- 日本保健物理学会の論文
著者
関連論文
- Estimation of Organ Dose in the Rat Exposed to X-rays for Radiobiological Study by TLD Implantation Method
- 討論会「ICRP 2005 年新勧告の論点」を開催して
- ICRP新呼吸気道モデルのラドンへの適用
- 固体飛跡検出器CR-39におけるAgingとFadingの影響
- IAEA調整研究プログラム「放射性核種摂取評価における相互比較と体内動態モデルの有効性」に関する研究調整会議
- 原子間力顕微鏡による微小核飛跡の解析
- ICRP新呼吸気道モデルに基づく^Puの内部被曝線量評価における粒子性状依存性
- α放射体のマクロオ-トラジオグラフィにおける固体飛跡検出器TS-16Nの撮像媒体としての特性〔英文〕
- 1.29MeVから5.48MeVのα粒子に対するCR-39プラスチックのエッチピット径のエネルギ-依存性〔英文〕
- TLDバックグランドの窒素ガスフロ-による低減化効果の評価〔英文〕
- 簡易型較正用α線照射容器〔英文〕
- ICRPの内部被ばく線量評価モデルに基づく^Puのモニタリング量の計算
- 5. 生物学的安全性評価研究におけるプルトニウムの線量評価
- Lung Retention of Pu Following Inhalation of PuO2 in Rats Measured Using a Whole Body Counter
- A Device for In Vitro Irradiation with α-Particles Using an (α-Emitting Radioactive Source
- Effects of DTPA Therapy on Removal of Inhaled High-fired Plutonium Oxide in Rats
- 原子間力顕微鏡による粒子線飛跡の微小エッチピットの解析法
- Activity Measurement of Plutonium in Solid Samples by LX-ray Counting with a Phoswich Detector.
- Characteristics of Plutonium Oxide Aerosol Particles Generated by Nebulization.
- Assessment of Initial Alveolar Deposition on Rats Exposed to Plutonium Aerosols Using a Whole Body Counter.
- Application of the TV device manufactured for image analyzation to the measurement of etch pit diameter.
- Batch variations of CR-39 plastic track detector in .ALPHA.-track registration properties.
- Evaluation of background in CR-39 detector for .ALPHA.-particle detection.
- Bulk-etch rate of CR-39 detector under various conditions of temperature and concentration of NaOH solution.