Intraoperative EEG Monitoring : (II) Similarity Analysis Using Density-modulated t Array
スポンサーリンク
概要
- 論文の詳細を見る
A method of showing the similarity, in other words, defining the difference between a pair of EEG patterns has been developed. By using the student t test on the power spectra at the appropriate frequency intervals, the t values obtained can be used as an indicator of the difference between the spectral patterns with respect to the frequency intervals. This so-called t-profile can be computed on real time basis and the result superimposed in different colors using the apparatus described previously to produce a 3-dimensional picture. We call this picture a density-modulated t array or DTA. Along with CSA and DSA (compressed/density-modulated spectral arrays), it proved to be a very powerful tool in intraoperative EEG monitoring.
- 東海大学の論文
著者
-
IGA Tomiei
Department of Psychiatry, Course of Specialized Clinical Science, Tokai University School of Medicin
-
Shirakura Katsuyuki
Department of Psychiatry and Behavioral Science, Tokai University School of Medicine
-
Iga Tomiei
Department Of Psychiatry And Behavioral Science School Of Medicine Tokai University
-
Kinefuchi Yoshio
Department Of Biomedical Engineering Tokai University School Of High-technology For Human Welfare
-
Kinefuchi Yoshio
Department Of Anesthesiology School Of Medicine Tokai University
-
Ohtani Ikuko
Department Of Anesthesiology School Of Medicine Tokai University
-
Shirakura Katsuyuki
Department Of Psychiatry And Behavioral Science School Of Medicine Tokai University
-
Shirakura Katsuyuki
Department Of Psychiatry & Behavioral Science Tokai University School Of Medicine
-
KATOH Hidekazu
Department of Anesthesiology, School of Medicine, Tokai University
-
YAMASAKI Yonosuke
Department of Anesthesiology, School of Medicine, Tokai University
-
Katoh Hidekazu
Department Of Anesthesiology School Of Medicine Tokai University
-
Yamasaki Yonosuke
Department Of Anesthesiology School Of Medicine Tokai University
関連論文
- Serotonin transporter gene promoter polymorphism and autism : A family-based genetic association study in Japanese population
- Biofeedback Training for Bronchial Asthma (Part I)
- A Trial of Biofeedback Treatment for Alopecia Areata
- An Effect of Appreciating Music on Emotion : Follow Up of the Profile of Mood States Score Before and After Appreciating Music
- Biofeedback Studies as seen in Literature : Part 2. Trend of and Present Situation in JICST
- Case Reports : Biofeedback Training for Alopecia Areata
- Biofeedback Training for Bronchial Asthma (Part II)
- EEG-αActivity Biofeedback Training : Application to Insomnia Patients
- Trend of Biofeedback Studies in Japan as viewed from Literature
- Biofeedback Training for EEG-α Activities : Part 2 : Polygraphic Study on Biofeedback Training for α Activities
- Biofeedback Training for EEG-α Activities : Part 1 : Centering around α-enhancement in healthy volunteers and neurotic patients
- On the Trend of Biofeedback Studies as seen in CIM
- CHRONOLOGICAL ASPECT OF BIOFEEDBACK TRAINING IN JAPAN
- Biofeedback; A Review of Its Clinical Efficacy in China
- Intraoperative EEG Monitoring : (II) Similarity Analysis Using Density-modulated t Array
- Intraoperative EEG Monitoring : (I) Parametric Representation of Processed EEG during Anesthesia
- Application of a Screening Test for Depression in the Health Counselling Center
- Design and its application of the f_n-ζchart capable of direct readout of the highest frequency indicating the limit of obtaining distortion-free waveforms
- Development of a New Catheter-tip Pressure Transducer
- The use of Sevoflurane Anesthesia during Early Pregnancy
- An Improved Puncture-Insertion Kit for a Swan-Ganz Catheter
- Respiratory Impedance Estimated from Airway and Intrapleural Pressure Curves
- A pilot/introducer needle for central vein cannulation
- 大動脈・橈骨動脈間の動脈壁弾性率分布の推定
- 麻酔中における気管内チューブのカフ内圧上昇の原因とその対策について
- One-lung ventilation with the Univent tube in a pediatric patient undergoing video-assisted thoracoscopic surgery
- Effects of Inhalation Anesthetics on Airway Dynamics Determined by Phasor Analysis of Respiratory Impedance Using the Forced Oscillation Method
- Parameter Estimation of Respiratory Impedance Measured by Forced Complex-wave Oscillations
- Clinical Application of Biofeedback Treatment with a Microvibration Transducer
- PREFACE
- PREFACE
- Use of personal computers for translation and publication of an anesthesia textbook
- Pa17 ABSOLUTE STEREOCHEMISTRY OF SOME MARINE DITERPENES : CONSIDERATION ON THE VALIDITY OF MOSHER'S RULE