Delta Check System for Detection and Further Management of Laboratory Errors : Second Report. Computer Program to Identify Laboratory Errors
スポンサーリンク
概要
- 論文の詳細を見る
A delta-check system has been introduced for routine work in our laboratory to detect laboratory errors in blood chemistry. All pairs of data that exceed allowable limits were displayed for each item. To easily understand the details, these data were displayed on a graph divided for each analyzer. Looking at this graph the responsible causes were inferred from the number or type of analyzers and from the number of items in which errors were detected. Following this first report, the algorithm involved in the last processes was programed. When all data derived from analyzers were put into the personal computer, 1) the details of errors were shown separately for each analyzer and item, and 2) presumed causes to be identified finally from the results of confirmative tests were displayed graphically at the same time according to our program. By this system, most of the errors that may happen during the whole course of tests, from the time a laboratory test was ordered until it was interpreted, were detected more rapidly, thoroughly and objectively inside the laboratory before the data were reported to the clinical ward. This system is also regarded as an indispensable base for the development of an accurate interpretation of laboratory data.
- 東海大学の論文
著者
-
Niwa Masaharu
Department Of Clinical Pathology School Of Medicine Tokai University
-
Miyamoto Motoaki
Central Cilinical Laboratory Tokai University Hospital
-
Shimizu Hiroshi
Central Clinical Laboratory Tokai University Hospital:(present Address)department Of Medical Informa
関連論文
- Quantitative Thin-Layer Chromatography with a Flame Ionization Detector for Serum Lipid Measurements in the Routine Clinical Laboratory
- A Case of Acute Myeloblastic Leukemia with Chromosomes Showing 46, XY=11/46, XY, 21q-=39
- A Variant Translocation (11; 22) (p15; q11) in a Patient with Chronic Myelocytic Leukemia
- Interpretation of Pathophysiology by Laboratory Data (3) A Consultation Program Based on Clinical Laboratory Data
- Studies on the Rapid Determination of Glucose Level in Blood Using the Enzyme Electrode, the "Glucose Meter"
- Evaluation of an Automated Differential Leukocyte Counting System "Hematrak"
- Study on Erythrocyte Lipids and Osmotic Fragility in Elderly People with Anemia
- The Current Concepts of "Normal Values" and "Clinical Reference Values" in the Clinical Laboratory : Trials for Determining Clinical Reference Values of the Tokai University Hospital
- Drug-Induced False Positive Tests for Protein in Urine Specimens from the Automated Multiphasic Health Testing Services of Tokai University Hospital
- Standard-Deviation-Index-Pattern Analysis of Blood Chemical Data in Health Check-Ups for Chronic Liver Disease : A Clinico-Pathological Study
- A Case with Silent Type of Pseudo-Acholinesterasemia
- Plasma Antithrombin III, _-Plasmin Inhibitor and Plasminogen Activities in Cases of Various Liver Diseases
- Study of Urinary Specific Gravity by Reagent Strip Method
- Interpretaion of Patho-physiology by Laboratory Data (4) Cases of Hypernutritional Fatty Liver
- Interpretation of Pathophysiology by Laboratory Data (1) Graphic Display of Data, Static Pattern
- A Practical Evaluation of Accuracy with the Standard Deviation Index (SDI) Chart Method Second Report : Report Covering the Period from April 1980 to March 1983
- Delta Check System for Detection and Further Management of Laboratory Errors : Second Report. Computer Program to Identify Laboratory Errors
- Delta Check System for Detection and Further Management of Laboratory Errors : First Report Graphical Presentation of Results
- Interpretation of Pathophysiology by Laboratory Data (2) Graphic Display of Data, Dynamic Pattern